Diode array digital radiography: initial clinical experience.

D Sashin, E J Sternglass, B S Slasky, K M Bron, J M Herron, W H Kennedy, L Shabason, J Boyer, A E Pollitt, R E Latchaw, B R Girdany, R W Simpson.   

Abstract

Initial clinical results are described for a new method of digital radiography based on high-detail self-scanning linear diode arrays which overcome many of the limitations of present film or other digital methods. The technique uses a fan-shaped x-ray beam to produce a nearly scatter-free image on a phosphor strip that is fiber-optically coupled to six self-scanning arrays of light-sensitive diodes spaced 0.025 mm, thus providing 6,144 discrete sensors across the field of view. Because these diodes have a greatly expanded dynamic range and operate at very low noise, it becomes possible to visualize small density differences or contrast below 1% both in the light and dark areas of the image. Because of the efficiency of detection and display, radiation doses can be reduced for a given information content. Our preliminary clinical studies have shown to broad application of our method in examining the chest and abdomen and in performing intravenous digital arteriography.

Mesh:

Substances:

Year:  1982        PMID: 6983247     DOI: 10.2214/ajr.139.6.1045

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  5 in total

1.  Rejection and redistribution of scattered radiation in scan equalization digital radiography (SEDR): simulation with spot images.

Authors:  Xinming Liu; Chris C Shaw
Journal:  Med Phys       Date:  2007-07       Impact factor: 4.071

2.  Scatter rejection and low-contrast performance of a slot-scan digital chest radiography system with electronic aft-collimation: a chest phantom study.

Authors:  Xinming Liu; Chris C Shaw; Chao-Jen Lai; Mustafa C Altunbas; Lingyun Chen; Tao Han; Tianpeng Wang
Journal:  Med Phys       Date:  2008-06       Impact factor: 4.071

3.  Comparison of scatter rejection and low-contrast performance of scan equalization digital radiography (SEDR), slot-scan digital radiography, and full-field digital radiography systems for chest phantom imaging.

Authors:  Xinming Liu; Chris C Shaw; Chao-Jen Lai; Tianpeng Wang
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

4.  An alternate line erasure and readout (ALER) method for implementing slot-scan imaging technique with a flat-panel detector--initial experiences.

Authors:  Xinming Liu; Chris C Shaw; Mustafa C Altunbas; Tianpeng Wang
Journal:  IEEE Trans Med Imaging       Date:  2006-04       Impact factor: 10.048

5.  Scan equalization digital radiography (SEDR) implemented with an amorphous selenium flat-panel detector: initial experience.

Authors:  Xinming Liu; Chao-Jen Lai; Lingyun Chen; Tao Han; Yuncheng Zhong; Youtao Shen; Tianpeng Wang; Chris C Shaw
Journal:  Phys Med Biol       Date:  2009-11-04       Impact factor: 3.609

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.