Literature DB >> 16572344

Surgical planning of total hip arthroplasty: accuracy of computer-assisted EndoMap software in predicting component size.

Jesse A Davila1, Mark J Kransdorf, Gavan P Duffy.   

Abstract

PURPOSE: The purpose of our study was to assess the accuracy of a computer-assisted templating in the surgical planning of patients undergoing total hip arthroplasty utilizing EndoMap software (Siemans AG, Medical Solutions, Erlangen, Germany). Endomap Software is an electronic program that uses DICOM images to analyze standard anteroposterior radiographs for determination of optimal prosthesis component size.
METHODS: We retrospectively reviewed the preoperative radiographs of 36 patients undergoing uncomplicated primary total hip arthroplasty, utilizing EndoMap software, Version VA20. DICOM anteroposterior radiographs were analyzed using standard manufacturer supplied electronic templates to determine acetabular and femoral component sizes. No additional clinical information was reviewed. Acetabular and femoral component sizes were assessed by an orthopedic surgeon and two radiologists. Mean and estimated component size was compared with component size as documented in operative reports.
RESULTS: The mean estimated acetabular component size was 53 mm (range 48-60 mm), 1 mm larger than the mean implanted size of 52 mm (range 48-62 mm). Thirty-one of 36 acetabular component sizes (86%) were accurate within one size. The mean calculated femoral component size was 4 (range 2-7), 1 size smaller than the actual mean component size of 5 (range 2-9). Twenty-six of 36 femoral component sizes (72%) were accurate within one size, and accurate within two sizes in all but four cases (94%).
CONCLUSION: EndoMap Software predicted femoral component size well, with 72% within one component size of that used, and 94% within two sizes. Acetabular component size was predicted slightly better with 86% within one component size and 94% within two component sizes.

Entities:  

Mesh:

Year:  2006        PMID: 16572344     DOI: 10.1007/s00256-006-0106-4

Source DB:  PubMed          Journal:  Skeletal Radiol        ISSN: 0364-2348            Impact factor:   2.199


  11 in total

1.  Hip-Op: an innovative software to plan total hip replacement surgery.

Authors:  Riccardo Lattanzi; Marco Viceconti; Cinzia Zannoni; Paolo Quadrani; Aldo Toni
Journal:  Med Inform Internet Med       Date:  2002-06

2.  Preoperative planning for total hip arthroplasty. Quantitating its utility and precision.

Authors:  J L Knight; R D Atwater
Journal:  J Arthroplasty       Date:  1992       Impact factor: 4.757

Review 3.  Preoperative planning for primary total hip arthroplasty.

Authors:  Alejandro González Della Valle; Douglas E Padgett; Eduardo A Salvati
Journal:  J Am Acad Orthop Surg       Date:  2005-11       Impact factor: 3.020

4.  Digital templating in total hip arthroplasty.

Authors:  James V Bono
Journal:  J Bone Joint Surg Am       Date:  2004       Impact factor: 5.284

Review 5.  Lessons of 30 years of total hip arthroplasty.

Authors:  M E Müller
Journal:  Clin Orthop Relat Res       Date:  1992-01       Impact factor: 4.176

6.  The precision and usefulness of preoperative planning for cemented and hybrid primary total hip arthroplasty.

Authors:  Alejandro González Della Valle; Gastón Slullitel; Francisco Piccaluga; Eduardo A Salvati
Journal:  J Arthroplasty       Date:  2005-01       Impact factor: 4.757

7.  Comparison of analog and digital preoperative planning in total hip and knee arthroplasties. A prospective study of 173 hips and 65 total knees.

Authors:  Bertram The; Ron L Diercks; Peter M A van Ooijen; Jim R van Horn
Journal:  Acta Orthop       Date:  2005-02       Impact factor: 3.717

8.  Electronic imaging impact on image and report turnaround times.

Authors:  C W Mattern; B F King; N J Hangiandreou; A Swenson; L L Jorgenson; W E Webbles; T W Okrzynski; B J Erickson; B Williamson; G S Forbes
Journal:  J Digit Imaging       Date:  1999-05       Impact factor: 4.056

9.  Effect of filmless imaging on the utilization of radiologic services.

Authors:  B I Reiner; E L Siegel; C Flagle; F J Hooper; R E Cox; M Scanlon
Journal:  Radiology       Date:  2000-04       Impact factor: 11.105

10.  Determination of accuracy of preoperative templating of noncemented femoral prostheses.

Authors:  L W Carter; D O Stovall; T R Young
Journal:  J Arthroplasty       Date:  1995-08       Impact factor: 4.757

View more
  21 in total

1.  [Implant position of total hip arthroplasty shafts. Establishment of a new method for comparison between planned and achieved shaft positions].

Authors:  A Fottner; A Steinbrück; E Volkmer; F Haasters; F Mazoochian; V Jansson
Journal:  Orthopade       Date:  2012-07       Impact factor: 1.087

2.  Design and implementation of gradient vector flow snake to detect a reference object in pelvic x-rays for preoperative total hip arthroplasty planning application.

Authors:  W Kristanto; P M A van Ooijen; B The; H Duifhuis; T R Mengko; M Oudkerk
Journal:  J Digit Imaging       Date:  2007-12       Impact factor: 4.056

3.  Validity and reliability of preoperative templating in total hip arthroplasty using a digital templating system.

Authors:  Ari Bertz; Kari Indrekvam; Mohamed Ahmed; Erling Englund; Arkan S Sayed-Noor
Journal:  Skeletal Radiol       Date:  2012-05-16       Impact factor: 2.199

4.  Assessment of magnification of digital pelvic radiographs in total hip arthroplasty using templating software.

Authors:  S P White; J Bainbridge; E J Smith
Journal:  Ann R Coll Surg Engl       Date:  2008-10       Impact factor: 1.891

5.  Determination of digitised radiograph magnification factors for pre-operative templating in hip prosthesis surgery.

Authors:  Stephane Descamps; Christine Livesey; Ian Douglas Learmonth
Journal:  Skeletal Radiol       Date:  2009-09-16       Impact factor: 2.199

6.  Preoperative digital planning versus postoperative outcomes in total hip arthroplasty using a calcar-guided short stem: frequent valgization can be avoided.

Authors:  Karl Philipp Kutzner; Joachim Pfeil; Mark Predrag Kovacevic
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-04-08

7.  Templating in uncemented total hip arthroplasty-on intra- and interobserver reliability and professional experience.

Authors:  Nils J Strøm; Are Hugo Pripp; Olav Reikerås
Journal:  Ann Transl Med       Date:  2017-02

8.  Significance of proximal femoral computed tomography scanning in the prediction of femoral prosthesis before total hip arthroplasty.

Authors:  Yizhong Li; Jinkuang Lin; Jing Zhang; Jianlong Li; Xuedong Yao; Huafeng Zhuang; Yanjun Zeng
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-01-29

9.  Factors related to disagreement in implant size between preoperative CT-based planning and the actual implants used intraoperatively for total hip arthroplasty.

Authors:  Takeshi Ogawa; Masaki Takao; Takashi Sakai; Nobuhiko Sugano
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-12-13       Impact factor: 2.924

10.  Acetate templating on digital images is more accurate than computer-based templating for total hip arthroplasty.

Authors:  Robert Petretta; Jason Strelzow; Nicholas E Ohly; Peter Misur; Bassam A Masri
Journal:  Clin Orthop Relat Res       Date:  2015-12       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.