Literature DB >> 15788312

Comparison of analog and digital preoperative planning in total hip and knee arthroplasties. A prospective study of 173 hips and 65 total knees.

Bertram The1, Ron L Diercks, Peter M A van Ooijen, Jim R van Horn.   

Abstract

INTRODUCTION: Digital correction of the magnification factor is expected to yield more accurate and reliable preoperative plans. We hypothesized that digital templating would be more accurate than manual templating for total hip and knee arthroplasties. PATIENTS AND METHODS: Firstly, we established the interobserver and intraobserver reliability of the templating procedure. The accuracy and reliability of digital and analog plans were measured in a series of 238 interventions, which were all planned using both techniques.
RESULTS: Interobserver reliability was good for the planning of knee arthroplasties (e-values 0.63-0.75), but not more than moderate for the planning of hip arthroplasties (e-values 0.22-0.54). Analog plans of knee arthroplasties systematically underestimated the component sizes (1.1 size on average), while the digital procedure proved to be accurate (0.1-0.4 size too small on average). The following figures show percentage of cases receiving a correct implant, allowing an error of one size. Digital templating of the hip arthroplasty was less frequently correct (cemented cup and stem: 72% and 79%; uncemented cup and stem: 52% and 66%) than analog planning (cemented cup and stem: 73% and 89%; uncemented cup and stem: 64% and 52%).
INTERPRETATION: Planning of component sizes for total knee arthroplasties is an accurate procedure when performed digitally. Our digital preoperative plans which were performed by someone other than the surgeon were less accurate than the analog plans prepared by the surgeon.

Entities:  

Mesh:

Year:  2005        PMID: 15788312     DOI: 10.1080/00016470510030364

Source DB:  PubMed          Journal:  Acta Orthop        ISSN: 1745-3674            Impact factor:   3.717


  31 in total

1.  Surgical planning of total hip arthroplasty: accuracy of computer-assisted EndoMap software in predicting component size.

Authors:  Jesse A Davila; Mark J Kransdorf; Gavan P Duffy
Journal:  Skeletal Radiol       Date:  2006-03-30       Impact factor: 2.199

2.  Comparison of techniques for correction of magnification of pelvic X-rays for hip surgery planning.

Authors:  Bertram The; Johan W J Kootstra; Anton H Hosman; Nico Verdonschot; Carina L E Gerritsma; Ron L Diercks
Journal:  J Digit Imaging       Date:  2007-12       Impact factor: 4.056

3.  The utility and precision of analogue and digital preoperative planning for total hip arthroplasty.

Authors:  Alejandro González Della Valle; Fernando Comba; Nicole Taveras; Eduardo A Salvati
Journal:  Int Orthop       Date:  2007-04-03       Impact factor: 3.075

4.  Validity and reliability of preoperative templating in total hip arthroplasty using a digital templating system.

Authors:  Ari Bertz; Kari Indrekvam; Mohamed Ahmed; Erling Englund; Arkan S Sayed-Noor
Journal:  Skeletal Radiol       Date:  2012-05-16       Impact factor: 2.199

5.  Sagittal cutting error changes femoral anteroposterior sizing in total knee arthroplasty.

Authors:  Hiroyuki Nakahara; Shuichi Matsuda; Ken Okazaki; Yasutaka Tashiro; Yukihide Iwamoto
Journal:  Clin Orthop Relat Res       Date:  2012-05-19       Impact factor: 4.176

6.  Reliability of preoperative measurement with standardized templating in Total Knee Arthroplasty.

Authors:  Daniel Hernandez-Vaquero; Ferran Abat; Juan Sarasquete; Juan Carlos Monllau
Journal:  World J Orthop       Date:  2013-10-18

7.  Determination of digitised radiograph magnification factors for pre-operative templating in hip prosthesis surgery.

Authors:  Stephane Descamps; Christine Livesey; Ian Douglas Learmonth
Journal:  Skeletal Radiol       Date:  2009-09-16       Impact factor: 2.199

8.  Preoperative digital planning versus postoperative outcomes in total hip arthroplasty using a calcar-guided short stem: frequent valgization can be avoided.

Authors:  Karl Philipp Kutzner; Joachim Pfeil; Mark Predrag Kovacevic
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-04-08

9.  Templating in uncemented total hip arthroplasty-on intra- and interobserver reliability and professional experience.

Authors:  Nils J Strøm; Are Hugo Pripp; Olav Reikerås
Journal:  Ann Transl Med       Date:  2017-02

10.  Acetate templating on digital images is more accurate than computer-based templating for total hip arthroplasty.

Authors:  Robert Petretta; Jason Strelzow; Nicholas E Ohly; Peter Misur; Bassam A Masri
Journal:  Clin Orthop Relat Res       Date:  2015-12       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.