Literature DB >> 1728996

Lessons of 30 years of total hip arthroplasty.

M E Müller1.   

Abstract

The following are lessons of 30 years of total hip arthroplasty (THA): Prosthetic components should allow for easy preoperative graphic planning with one or two templates only. Polyethylene is the weak link in THA and ought to be replaced by perfectly concentric metallic sockets and femoral heads of casted Cr/Co/Mo alloys. The operating technique should guarantee large exposure, suitable orientation of both components, and adequate fixation. Loosening is correlated with loss of bone stock and changes of the position of the implants. In case of progressive bone loss, one should reoperate already in presence of slight clinical symptoms to prevent more difficult and dangerous revisions. To evaluate objectively the outcome of THA, a combined data and roentgenographic documentation system with standardized terms and scales is necessary.

Entities:  

Mesh:

Year:  1992        PMID: 1728996

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  15 in total

1.  To what degree is digital imaging reliable? Validation of femoral neck shaft angle measurement in the era of picture archiving and communication systems.

Authors:  J D Wilson; W Eardley; S Odak; A Jennings
Journal:  Br J Radiol       Date:  2010-12-15       Impact factor: 3.039

2.  Surgical planning of total hip arthroplasty: accuracy of computer-assisted EndoMap software in predicting component size.

Authors:  Jesse A Davila; Mark J Kransdorf; Gavan P Duffy
Journal:  Skeletal Radiol       Date:  2006-03-30       Impact factor: 2.199

3.  Reliability of preoperative measurement with standardized templating in Total Knee Arthroplasty.

Authors:  Daniel Hernandez-Vaquero; Ferran Abat; Juan Sarasquete; Juan Carlos Monllau
Journal:  World J Orthop       Date:  2013-10-18

4.  Provisional results of the CLS cup using IDES.

Authors:  R Orozco; P F Koch; J Girós; J M Sales
Journal:  Int Orthop       Date:  1994       Impact factor: 3.075

5.  DICOM for implantations--overview and application.

Authors:  Thomas Treichel; Michael Gessat; Torsten Prietzel; Oliver Burgert
Journal:  J Digit Imaging       Date:  2012-06       Impact factor: 4.056

Review 6.  [Development of hip resurfacing].

Authors:  H Rechl; H Pilge; M Rudert
Journal:  Orthopade       Date:  2008-07       Impact factor: 1.087

7.  Influence of the acetabular cup position on hip load during arthroplasty in hip dysplasia.

Authors:  Goran Bicanic; Domagoj Delimar; Marko Delimar; Marko Pecina
Journal:  Int Orthop       Date:  2008-11-18       Impact factor: 3.075

8.  The cementless Bicontact stem in a prospective dual-energy X-ray absorptiometry study.

Authors:  Matthias Lerch; Agnes Kurtz; Henning Windhagen; Anas Bouguecha; Bernd A Behrens; Patrick Wefstaedt; Christina M Stukenborg-Colsman
Journal:  Int Orthop       Date:  2012-08-04       Impact factor: 3.075

9.  The 3-dot circle: A reliable method for safe and efficient digital templating of the acetabular component.

Authors:  Firas Arnaout; Varun Dewan; Christos Paliobeis
Journal:  J Orthop       Date:  2018-03-27

10.  Total Hip Arthroplasty Digital Templating: Size Predicting Ability and Interobserver Variability.

Authors:  Veronica Montiel; Santiago Troncoso; Andrés Valentí-Azcárate; Juan Ramón Valentí-Nin; Jose María Lamo-Espinosa
Journal:  Indian J Orthop       Date:  2020-08-03       Impact factor: 1.251

View more