Factors related to disagreement in implant size between preoperative CT-based planning and the actual implants used intraoperatively for total hip arthroplasty.

Takeshi Ogawa1, Masaki Takao1, Takashi Sakai2, Nobuhiko Sugano3.   

Abstract

PURPOSE: In total hip arthroplasty, prediction of the optimal implant size is important in order to prevent perioperative complications. However, it is not easy to achieve complete agreement between the planned size and the actual size required appropriate implant fit. No previous report has adequately discussed the factors related to mismatch between predicted and actual implant sizes. The purpose was to report the results of a single surgeon case series of patients undergoing THA using computed tomography (CT)-based templating and the possible factors related to implant size mismatch.
METHODS: The study included 141 hips of 126 patients who underwent primary total hip arthroplasty with CT-based navigation. We retrospectively reviewed the planned and actual implant sizes used in these patients. Cup position, cup orientation and stem alignment were evaluated as surgical factors that could possibly be related to mismatch in implant size. Cortical index and canal flare index were also evaluated as morphological factors.
RESULTS: The final inclusions in this study were 124 hips of 111 patients including 82% of those were developmental dysplasia of the hip. Agreement in implant size was seen for 94.4% of cups and 85.5% of stems, respectively. No related factors were found for cup size mismatch. Stem alignment in the sagittal and coronal planes showed significant differences between the size-matched stem group and the smaller stem group ([Formula: see text]).
CONCLUSIONS: Implant size agreement rates between the three-dimensional plan and the actual implants used intraoperatively were high. However, broach alignment should be checked in the coronal and sagittal planes if the intraoperative broach is smaller than the planned size.

Entities:  

Keywords:  CT-based navigation; Implant size; Preoperative planning; Three-dimensional planning; Total hip arthroplasty

Mesh:

Year:  2017        PMID: 29236207     DOI: 10.1007/s11548-017-1693-3

Source DB:  PubMed          Journal:  Int J Comput Assist Radiol Surg        ISSN: 1861-6410            Impact factor:   2.924


  36 in total

1.  Mid-term results of cementless total hip replacement using a ceramic-on-ceramic bearing with and without computer navigation.

Authors:  N Sugano; T Nishii; H Miki; H Yoshikawa; Y Sato; S Tamura
Journal:  J Bone Joint Surg Br       Date:  2007-04

2.  Comparison of navigation accuracy in THA between the mini-anterior and -posterior approaches.

Authors:  Takehito Hananouchi; Masaki Takao; Takashi Nishii; Hidenobu Miki; Daiki Iwana; Hideki Yoshikawa; Nobuhiko Sugano
Journal:  Int J Med Robot       Date:  2009-03       Impact factor: 2.547

3.  Accuracy of reconstruction of the hip using computerised three-dimensional pre-operative planning and a cementless modular neck.

Authors:  E Sariali; A Mouttet; G Pasquier; E Durante; Y Catone
Journal:  J Bone Joint Surg Br       Date:  2009-03

4.  Accuracy of angle and position of the cup using computed tomography-based navigation systems in total hip arthroplasty.

Authors:  Daiki Iwana; Nobuo Nakamura; Hidenobu Miki; Makoto Kitada; Takehito Hananouchi; Nobuhiko Sugano
Journal:  Comput Aided Surg       Date:  2013-07-17

5.  Comparing the accuracy of radiographic preoperative digital templating for a second- versus a first-generation THA stem.

Authors:  Kimona Issa; Robert Pivec; Bradley Boyd; Steven F Harwin; Thies Wuestemann; Jim Nevelos; Michael A Mont
Journal:  Orthopedics       Date:  2012-12       Impact factor: 1.390

6.  Accuracy of the preoperative planning for cementless total hip arthroplasty. A randomised comparison between three-dimensional computerised planning and conventional templating.

Authors:  E Sariali; R Mauprivez; F Khiami; H Pascal-Mousselard; Y Catonné
Journal:  Orthop Traumatol Surg Res       Date:  2012-02-29       Impact factor: 2.256

7.  Total hip replacement in congenital dislocation and dysplasia of the hip.

Authors:  J F Crowe; V J Mani; C S Ranawat
Journal:  J Bone Joint Surg Am       Date:  1979-01       Impact factor: 5.284

8.  The definition and measurement of acetabular orientation.

Authors:  D W Murray
Journal:  J Bone Joint Surg Br       Date:  1993-03

9.  The morphology of the femur in developmental dysplasia of the hip.

Authors:  N Sugano; P C Noble; E Kamaric; J K Salama; T Ochi; H S Tullos
Journal:  J Bone Joint Surg Br       Date:  1998-07

10.  Uncemented grit-blasted straight tapered titanium stems in patients younger than fifty-five years of age. Fifteen to twenty-year results.

Authors:  Peter R Aldinger; Alexander W Jung; Maria Pritsch; Steffen Breusch; Marc Thomsen; Volker Ewerbeck; Dominik Parsch
Journal:  J Bone Joint Surg Am       Date:  2009-06       Impact factor: 5.284

View more
  3 in total

1.  Predicting Implant Size in Total Hip Arthroplasty.

Authors:  James B Chen; Alioune Diane; Stephen Lyman; Yu-Fen Chiu; Jason L Blevins; Geoffrey H Westrich
Journal:  Arthroplast Today       Date:  2022-04-02

2.  Utility of a novel integrated deep convolutional neural network for the segmentation of hip joint from computed tomography images in the preoperative planning of total hip arthroplasty.

Authors:  Dong Wu; Xin Zhi; Xingyu Liu; Yiling Zhang; Wei Chai
Journal:  J Orthop Surg Res       Date:  2022-03-15       Impact factor: 2.359

3.  Validation of CT-Based Three-Dimensional Preoperative Planning in Comparison with Acetate Templating for Primary Total Hip Arthroplasty.

Authors:  Xi Chen; Yiou Wang; Ruichen Ma; Huiming Peng; Shibai Zhu; Shanni Li; Songlin Li; Xiying Dong; Guixing Qiu; Wenwei Qian
Journal:  Orthop Surg       Date:  2022-05-07       Impact factor: 2.279

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.