Determination of accuracy of preoperative templating of noncemented femoral prostheses.

L W Carter1, D O Stovall, T R Young.   

Abstract

The purpose of this study was to determine the accuracy of preoperative templating of primary, noncemented femoral components. A retrospective review of charts and radiographs was performed on 74 hips in 64 patients who had undergone either noncemented total hip arthroplasty (THA) or placement of an endoprosthesis (including bipolar). Preoperative radiographs were templated by a total joint arthroplasty attending surgeon, a senior orthopaedic resident, and a junior resident. The templated size corresponded to the actual femoral implant used in approximately 50% of cases. When femoral prostheses within one size above or below the templated size were included, the accuracy of preoperative templating rose to 88-95%. When implants within two sizes of the templated size were included, the accuracy approached 100%. Factors associated with discrepancies in the size of femoral stem used included placement of an undersized implant, presence of metal hardware that obscured the ability to template accurately, proximal bone deformity, sclerotic bone, acute femoral neck fracture, and inadequate preoperative radiographs. The accuracy of templating increased gradually with the level of training. The most experienced investigator was able to template within one size of the actual implant used in 95% of cases, compared with 88% and 82% for the less experienced investigators. Acute femoral neck fractures and proximal bone deformity were associated with the largest discrepancies in templated sizes.

Entities:  

Mesh:

Year:  1995        PMID: 8523011     DOI: 10.1016/s0883-5403(05)80153-6

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  30 in total

1.  [Implant position of total hip arthroplasty shafts. Establishment of a new method for comparison between planned and achieved shaft positions].

Authors:  A Fottner; A Steinbrück; E Volkmer; F Haasters; F Mazoochian; V Jansson
Journal:  Orthopade       Date:  2012-07       Impact factor: 1.087

2.  Accuracy of templating the acetabular cup size in Total Hip Replacement using conventional acetate templates on digital radiographs.

Authors:  Vignesh P Krishnamoorthy; Rajamani Perumal; Alfred J Daniel; Pradeep M Poonnoose
Journal:  J Clin Orthop Trauma       Date:  2015-05-11

3.  Surgical planning of total hip arthroplasty: accuracy of computer-assisted EndoMap software in predicting component size.

Authors:  Jesse A Davila; Mark J Kransdorf; Gavan P Duffy
Journal:  Skeletal Radiol       Date:  2006-03-30       Impact factor: 2.199

4.  Comparison of techniques for correction of magnification of pelvic X-rays for hip surgery planning.

Authors:  Bertram The; Johan W J Kootstra; Anton H Hosman; Nico Verdonschot; Carina L E Gerritsma; Ron L Diercks
Journal:  J Digit Imaging       Date:  2007-12       Impact factor: 4.056

5.  The utility and precision of analogue and digital preoperative planning for total hip arthroplasty.

Authors:  Alejandro González Della Valle; Fernando Comba; Nicole Taveras; Eduardo A Salvati
Journal:  Int Orthop       Date:  2007-04-03       Impact factor: 3.075

6.  Digital versus conventional templating techniques in preoperative planning for total hip arthroplasty.

Authors:  Yona Kosashvili; Nadav Shasha; Eli Olschewski; Oleg Safir; Larry White; Allan Gross; David Backstein
Journal:  Can J Surg       Date:  2009-02       Impact factor: 2.089

7.  Validity and reliability of preoperative templating in total hip arthroplasty using a digital templating system.

Authors:  Ari Bertz; Kari Indrekvam; Mohamed Ahmed; Erling Englund; Arkan S Sayed-Noor
Journal:  Skeletal Radiol       Date:  2012-05-16       Impact factor: 2.199

8.  Assessment of magnification of digital pelvic radiographs in total hip arthroplasty using templating software.

Authors:  S P White; J Bainbridge; E J Smith
Journal:  Ann R Coll Surg Engl       Date:  2008-10       Impact factor: 1.891

9.  Radiographic templating of total hip arthroplasty for femoral neck fractures.

Authors:  Dror Lakstein; Ira Bachar; Ronen Debi; Omri Lubovsky; Ornit Cohen; Zachary Tan; Ehud Atoun
Journal:  Int Orthop       Date:  2016-06-07       Impact factor: 3.075

10.  Acetate templating on digital images is more accurate than computer-based templating for total hip arthroplasty.

Authors:  Robert Petretta; Jason Strelzow; Nicholas E Ohly; Peter Misur; Bassam A Masri
Journal:  Clin Orthop Relat Res       Date:  2015-12       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.