Literature DB >> 22732771

[Implant position of total hip arthroplasty shafts. Establishment of a new method for comparison between planned and achieved shaft positions].

A Fottner1, A Steinbrück, E Volkmer, F Haasters, F Mazoochian, V Jansson.   

Abstract

BACKGROUND: One of the main goals of the preoperative planning of hip prostheses is adequate shaft positioning with reconstruction of leg length and offset. The purpose of this study was to compare the planned and achieved shaft positions using a modified program for migration measurement.
METHODS: In 60 cases of total hip replacement the preoperative planning was compared with the postoperative radiograph using a modified version of the well-established EBRA-FCA program. The results of this new measurement were compared to conventional measurements. In 25 cases the intraobserver and interobserver reliability was determined.
RESULTS: The novel measurements correlated best with the measured distance between the greater trochanter and the center of rotation and yielded the best intraobserver and interobserver reliability. In general, cementless stems had a slightly more proximal position (0.65 mm) compared to cemented stems.
CONCLUSIONS: The modified program for migration measurement facilitates a reproducible and fast comparison of the planned and achieved shaft positions thus implementing an early and objective control of postoperative shaft position.

Entities:  

Mesh:

Year:  2012        PMID: 22732771     DOI: 10.1007/s00132-012-1961-4

Source DB:  PubMed          Journal:  Orthopade        ISSN: 0085-4530            Impact factor:   1.087


  24 in total

1.  Accuracy of EBRA-FCA in the measurement of migration of femoral components of total hip replacement. Einzel-Bild-Röntgen-Analyse-femoral component analysis.

Authors:  R Biedermann; M Krismer; B Stöckl; P Mayrhofer; E Ornstein; H Franzén
Journal:  J Bone Joint Surg Br       Date:  1999-03

2.  Precision of EBRA-Digital software for monitoring implant migration after total hip arthroplasty.

Authors:  J M Wilkinson; A J Hamer; R A Elson; I Stockley; R Eastell
Journal:  J Arthroplasty       Date:  2002-10       Impact factor: 4.757

3.  Comparison of preoperative templating with postoperative assessment in cementless total hip arthroplasty.

Authors:  Kuen Tak Suh; Sang Jin Cheon; Dae Woong Kim
Journal:  Acta Orthop Scand       Date:  2004-02

4.  Digital templating in total hip arthroplasty.

Authors:  James V Bono
Journal:  J Bone Joint Surg Am       Date:  2004       Impact factor: 5.284

5.  The utility and precision of analogue and digital preoperative planning for total hip arthroplasty.

Authors:  Alejandro González Della Valle; Fernando Comba; Nicole Taveras; Eduardo A Salvati
Journal:  Int Orthop       Date:  2007-04-03       Impact factor: 3.075

6.  Reproducibility and accuracy of templating uncemented THA with digital radiographic and digital TraumaCad templating software.

Authors:  Panamoottil G Anil Kumar; Sayyied J Kirmani; Heike Humberg; Venu Kavarthapu; Patrick Li
Journal:  Orthopedics       Date:  2009-11       Impact factor: 1.390

7.  The precision and usefulness of preoperative planning for cemented and hybrid primary total hip arthroplasty.

Authors:  Alejandro González Della Valle; Gastón Slullitel; Francisco Piccaluga; Eduardo A Salvati
Journal:  J Arthroplasty       Date:  2005-01       Impact factor: 4.757

8.  Femoral fit in ABG-II hip stems, influence on clinical outcome and bone remodeling: a radiographic study.

Authors:  B C H van der Wal; B J de Kramer; B Grimm; W Vencken; I C Heyligers; A J Tonino
Journal:  Arch Orthop Trauma Surg       Date:  2007-12-06       Impact factor: 3.067

9.  Accuracy of migration analysis in hip arthroplasty. Digitized and conventional radiography, compared to radiostereometry in 51 patients.

Authors:  H Malchau; J Kärrholm; Y X Wang; P Herberts
Journal:  Acta Orthop Scand       Date:  1995-10

10.  A new digital preoperative planning method for total hip arthroplasties.

Authors:  Hendrikus J A Crooijmans; Armand M R P Laumen; Carola van Pul; Jan B A van Mourik
Journal:  Clin Orthop Relat Res       Date:  2008-09-10       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.