| Literature DB >> 16447047 |
Fredrik Holmquist1, Ulf Nyman.
Abstract
The aim of this study was to assess the feasibility of minimising contrast-medium (CM) doses using 80-peak kilovoltage (kVp) 16-channel multidetector computed tomography (MDCT) with CM dose tailored to body weight, when diagnosing pulmonary embolism (PE) in azotaemic patients. Twenty-nine patients (68-93 years; 38-79 kg) with an estimated glomerular filtration rate of 12-49 ml/min underwent 80 kVp MDCT at a median dose of 200 mg iodine (I)/kg and 15 s injection time. Pulmonary artery (PA) enhancement where compared with our own reference material using 320 mg I/kg at 120 kVp and with reported figures in the literature at 120-140 kVp and a 42 g iodine CM dose. Median (1st and 3rd quartiles) values regarding CM dose were 12.2 (9.9-12.8) g iodine; density of left main and lower lobe segmental PA 339 (275-395) Hounsfield units (HU) and 354 (321-442) HU, respectively. Those enhancement values were similar to those obtained from the reference population at 120 kVp and those reported in the literature at 120-140 kVp. One patient had a transient increase in plasma creatinine. Three months' follow-up revealed deep venous thrombosis among 1/18 patients with negative results from computed tomography (CT). We conclude that 80 kVp 16-channel MDCT to diagnose PE in azotaemic patients may be performed with markedly reduced CM doses, implying a lesser risk for CM-induced nephropathy.Entities:
Mesh:
Substances:
Year: 2006 PMID: 16447047 DOI: 10.1007/s00330-005-0117-x
Source DB: PubMed Journal: Eur Radiol ISSN: 0938-7994 Impact factor: 5.315