Literature DB >> 15908557

MDCT angiography of the pulmonary arteries: influence of iodine flow concentration on vessel attenuation and visualization.

Helmut Schoellnast1, Hannes A Deutschmann, Gerald A Fritz, Uwe Stessel, Gottfried J Schaffler, Manfred Tillich.   

Abstract

OBJECTIVE: Our objective was to assess the influence of iodine flow concentration on attenuation and visualization of the pulmonary arteries in thoracic MDCT angiography.
MATERIALS AND METHODS: One hundred consecutive patients who were referred to our department with suspected acute pulmonary embolism underwent MDCT angiography of the pulmonary arteries either with 120 mL of standard contrast medium (300 mg I/mL) (group A) or with 90 mL of high-concentration contrast medium (400 mg I/mL) (group B). The contrast medium was injected at a flow rate of 4 mL/sec. The scan delay was determined using a semiautomatic bolus-tracking system in all examinations conducted with the same scanning parameters. Quantitative analysis was performed by region-of-interest measurements along the z-axis to compare the attenuation profiles of the two groups. Attenuation of the fourth-, fifth-, and sixth-order arteries was assessed visually for differences between the two groups.
RESULTS: The mean enhancement along the z-axis was 268 +/- 56 H in group A and 344 +/- 108 in group B. The difference of 76 H was statistically significant (p < 0.001). The attenuation profile was similar in both groups. The detection rate of fifth- and sixth-order arteries was significantly higher in group B than in group A (94% compared with 91% and 72% compared with 60%, respectively, p < 0.01).
CONCLUSION: Use of a high flow concentration of iodine in MDCT angiography of the pulmonary arteries significantly increases attenuation of the pulmonary arteries, thereby improving visualization of subsegmental pulmonary arteries.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15908557     DOI: 10.2214/ajr.184.6.01841935

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  15 in total

1.  Optimisation of contrast medium volume and injection-related factors in CT pulmonary angiography: 64-slice CT study.

Authors:  Selma Uysal Ramadan; Pinar Kosar; Iclal Sonmez; Sevilay Karahan; Ugur Kosar
Journal:  Eur Radiol       Date:  2010-05-01       Impact factor: 5.315

2.  MDCT for suspected pulmonary embolism: multi-institutional survey of 16-MDCT data acquisition protocols.

Authors:  Pamela T Johnson; David Naidich; Elliot K Fishman
Journal:  Emerg Radiol       Date:  2006-11-29

3.  Attenuation values of the intracranial arterial and venous vessels by bolus injection of various contrast agents: a study with a single-detector helical CT scanner.

Authors:  Morio Nagahata; Yoshinao Abe; Shuichi Ono; Hikaru Yamaguchi; Hiroyuki Miura; Takashi Ohata; Fumiyasu Tsushima; Kohei Morimoto; Hiroko Seino
Journal:  Radiat Med       Date:  2007-04-27

4.  Increasing contrast agent concentration improves enhancement in first-pass CT perfusion.

Authors:  H M Silvennoinen; L M Hamberg; L Valanne; G J Hunter
Journal:  AJNR Am J Neuroradiol       Date:  2007-08       Impact factor: 3.825

5.  Evaluation of subsubsegmental pulmonary arteries of the posterior and anterior segments of the right upper lobe using multidetector row computed tomography with multiplanar reconstruction images.

Authors:  Makiko Murota; Katashi Satoh; Yuka Yamamoto; Takuya Kobayashi; Yoshihiro Nishiyama
Journal:  Jpn J Radiol       Date:  2009-03-12       Impact factor: 2.374

6.  MDCT angiography of the pulmonary arteries: intravascular contrast enhancement does not depend on iodine concentration when injecting equal amounts of iodine at standardized iodine delivery rates.

Authors:  S Keil; C Plumhans; F F Behrendt; M Das; S Stanzel; G Mühlenbruch; P Seidensticker; C Knackstedt; A H Mahnken; R W Günther; J E Wildberger
Journal:  Eur Radiol       Date:  2008-04-08       Impact factor: 5.315

7.  Visualization of the azygos arch valves on multidetector-row computed tomography.

Authors:  Tamaki Ichikawa; Jun Endo; Jun Koizumi; Ayako Ro; Makiko Kobayashi; Midori Saito; Shuichi Kawada; Takeshi Hashimoto; Yutaka Imai
Journal:  Heart Vessels       Date:  2008-04-04       Impact factor: 2.037

8.  Comparison of image quality and radiation dose of different pulmonary CTA protocols on a 128-slice CT: high-pitch dual source CT, dual energy CT and conventional spiral CT.

Authors:  Tobias De Zordo; Klemens von Lutterotti; Christian Dejaco; Peter F Soegner; Renate Frank; Friedrich Aigner; Andrea S Klauser; Christoph Pechlaner; U Joseph Schoepf; Werner R Jaschke; Gudrun M Feuchtner
Journal:  Eur Radiol       Date:  2011-08-28       Impact factor: 5.315

9.  Bolus injection of contrast agents with various iodine concentrations and delivery rates for intracranial three-dimensional CT angiography: evaluation of intracranial arteriovenous contrast using a multidetector-row CT scanner.

Authors:  Morio Nagahata; Yoshinao Abe; Shuichi Ono; Hiroyuki Miura; Takashi Ohata; Fumiyasu Tsushima; Kohei Morimoto; Hiroko Seino; Shinya Kakehata; Kiyoshi Basaki
Journal:  Radiat Med       Date:  2008-10-31

10.  Does pregnancy affect vascular enhancement in patients undergoing CT pulmonary angiography?

Authors:  Adrian K Andreou; John J Curtin; Sue Wilde; Allan Clark
Journal:  Eur Radiol       Date:  2008-07-24       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.