Prospective randomised comparison of diagnostic confidence and image quality with normal-dose and low-dose CT pulmonary angiography at various body weights.

Zsolt Szucs-Farkas1, Boglarka Megyeri, Andreas Christe, Peter Vock, Johannes T Heverhagen, Sebastian T Schindera.   

Abstract

OBJECTIVES: To find a threshold body weight (BW) below 100 kg above which computed tomography pulmonary angiography (CTPA) using reduced radiation and a reduced contrast material (CM) dose provides significantly impaired quality and diagnostic confidence compared with standard-dose CTPA.
METHODS: In this prospectively randomised study of 501 patients with suspected pulmonary embolism and BW <100 kg, 246 were allocated into the low-dose group (80 kVp, 75 ml CM) and 255 into the normal-dose group (100 kVp, 100 ml CM). Contrast-to-noise ratio (CNR) in the pulmonary trunk was calculated. Two blinded chest radiologists independently evaluated subjective image quality and diagnostic confidence. Data were compared between the normal-dose and low-dose groups in five BW subgroups.
RESULTS: Vessel attenuation did not differ between the normal-dose and low-dose groups within each BW subgroup (P = 1.0). The CNR was higher with the normal-dose compared with the low-dose protocol (P < 0.006) in all BW subgroups except for the 90-99 kg subgroup (P = 0.812). Subjective image quality and diagnostic confidence did not differ between CT protocols in all subgroups (P between 0.960 and 1.0).
CONCLUSIONS: Subjective image quality and diagnostic confidence with 80 kVp CTPA is not different from normal-dose protocol in any BW group up to 100 kg. KEY POINTS: • 80 kVp CTPA is safe in patients weighing <100 kg • Reduced radiation and iodine dose still provide high vessel attenuation • Image quality and diagnostic confidence with low-dose CTPA is good • Diagnostic confidence does not deteriorate in obese patients weighing <100 kg.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24865694     DOI: 10.1007/s00330-014-3208-8

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  24 in total

1.  Technique factors and image quality as functions of patient weight at abdominal CT.

Authors:  W Huda; E M Scalzetti; G Levin
Journal:  Radiology       Date:  2000-11       Impact factor: 11.105

2.  Effect of area x-ray beam equalization on image quality and dose in digital mammography.

Authors:  Jerry Wong; Tong Xu; Adeel Husain; Huy Le; Sabee Molloi
Journal:  Phys Med Biol       Date:  2004-08-21       Impact factor: 3.609

3.  CT angiography of pulmonary arteries to detect pulmonary embolism: improvement of vascular enhancement with low kilovoltage settings.

Authors:  Claudia Schueller-Weidekamm; Cornelia M Schaefer-Prokop; Michael Weber; Christian J Herold; Mathias Prokop
Journal:  Radiology       Date:  2006-12       Impact factor: 11.105

4.  Low-tube-voltage (80 kVp) CT aortography using 320-row volume CT with adaptive iterative reconstruction: lower contrast medium and radiation dose.

Authors:  Chien-Ming Chen; Sung-Yu Chu; Ming-Yi Hsu; Ying-Lan Liao; Hui-Yu Tsai
Journal:  Eur Radiol       Date:  2013-10-02       Impact factor: 5.315

5.  Eighty-peak kilovoltage 16-channel multidetector computed tomography and reduced contrast-medium doses tailored to body weight to diagnose pulmonary embolism in azotaemic patients.

Authors:  Fredrik Holmquist; Ulf Nyman
Journal:  Eur Radiol       Date:  2006-01-27       Impact factor: 5.315

6.  Diagnostic accuracy of pulmonary CT angiography at low tube voltage: intraindividual comparison of a normal-dose protocol at 120 kVp and a low-dose protocol at 80 kVp using reduced amount of contrast medium in a simulation study.

Authors:  Zsolt Szucs-Farkas; Fabian Schibler; Jennifer Cullmann; Jaled Charimo Torrente; Michael A Patak; Stephan Raible; Hanno Hoppe; Rolf Wyttenbach; Peter Vock; Sebastian T Schindera
Journal:  AJR Am J Roentgenol       Date:  2011-11       Impact factor: 3.959

7.  Image quality and radiation dose of pulmonary CT angiography performed using 100 and 120 kVp.

Authors:  Randy Fanous; Hany Kashani; Laura Jimenez; Grainne Murphy; Narinder S Paul
Journal:  AJR Am J Roentgenol       Date:  2012-11       Impact factor: 3.959

8.  Vascular enhancement and image quality of MDCT pulmonary angiography in 400 cases: comparison of standard and low kilovoltage settings.

Authors:  Shin Matsuoka; Andetta R Hunsaker; Ritu R Gill; Isabel B Oliva; Beatrice Trotman-Dickenson; Francine L Jacobson; Hiroto Hatabu
Journal:  AJR Am J Roentgenol       Date:  2009-06       Impact factor: 3.959

9.  Effect of X-ray tube parameters, iodine concentration, and patient size on image quality in pulmonary computed tomography angiography: a chest-phantom-study.

Authors:  Zsolt Szucs-Farkas; Francis R Verdun; Gabriel von Allmen; Roberto L Mini; Peter Vock
Journal:  Invest Radiol       Date:  2008-06       Impact factor: 6.016

10.  Thoracoabdominal-aortoiliac multidetector-row CT angiography at 80 and 100 kVp: assessment of image quality and radiation dose.

Authors:  Sebastian T Schindera; Patricia Graca; Michael A Patak; Susanne Abderhalden; Gabriel von Allmen; Peter Vock; Zsolt Szucs-Farkas
Journal:  Invest Radiol       Date:  2009-10       Impact factor: 6.016

View more
  4 in total

1.  Ultra-low dose contrast CT pulmonary angiography in oncology patients using a high-pitch helical dual-source technology.

Authors:  Prabhakar Rajiah; Leslie Ciancibello; Ronald Novak; Jennifer Sposato; Luis Landeras; Robert Gilkeson
Journal:  Diagn Interv Radiol       Date:  2019-05       Impact factor: 2.630

Review 2.  Computed tomography of acute pulmonary embolism: state-of-the-art.

Authors:  Long Jiang Zhang; Guang Ming Lu; Felix G Meinel; Andrew D McQuiston; James G Ravenel; U Joseph Schoepf
Journal:  Eur Radiol       Date:  2015-03-13       Impact factor: 5.315

Review 3.  Imaging of suspected pulmonary embolism and deep venous thrombosis in obese patients.

Authors:  Vincent Cascio; Man Hon; Linda B Haramati; Animesh Gour; Peter Spiegler; Sanjeev Bhalla; Douglas S Katz
Journal:  Br J Radiol       Date:  2018-06-27       Impact factor: 3.039

4.  Ultra Low Dose CT Pulmonary Angiography with Iterative Reconstruction.

Authors:  Andreas Sauter; Thomas Koehler; Alexander A Fingerle; Bernhard Brendel; Vivien Richter; Michael Rasper; Ernst J Rummeny; Peter B Noël; Daniela Münzel
Journal:  PLoS One       Date:  2016-09-09       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.