Literature DB >> 22527361

Effects of patient size on radiation dose reduction and image quality in low-kVp CT pulmonary angiography performed with reduced IV contrast dose.

Aaron Sodickson1, Michael Weiss.   

Abstract

The purpose of the study is to evaluate image quality and radiation exposure as a function of patient size for CT pulmonary angiography (CTPA) performed at reduced tube voltage and reduced intravenous (IV) contrast dose. We reviewed consecutive CTPAs performed between 9/1/2010 and 10/31/2010 on a 128-slice Siemens AS+ scanner using automated tube current modulation with quality reference mAs 200 and IV contrast concentration 370 mg I/ml followed by a saline flush: 99 scans at 120 kVp using 75 ml of contrast at 5 ml/s and 53 scans on patients lighter than 175 lbs at 100 kVp using 50 ml of contrast at 4 ml/s. We measured patient size (mean water-equivalent diameter) using a topogram analysis tool, signal (mean CT density) and noise (standard deviation) in the main pulmonary artery (MPA) on axial images, and calculated local CTDI(vol) from the kVp and mAs. Linear regression models were created for dependent variables ln(CTDI(vol)), signal, noise, and signal to noise ratio (SNR) as a function of independent variables size, age, gender, and kVp. After controlling for other variables, scanning at 100 kVp yielded CTDI(vol) reduction of 33 % (p < 0.0001), signal increase of 96 HU (p < 0.0001), and increased image noise (p < 0.0001), but without significant difference in SNR (p = 0.99). Relative to 120 kVp, 100-kVp CTPA allows simultaneous reduction of radiation exposure by 33 % and IV contrast dose by 33 % while maintaining image quality. Scanning at 100 kVp is recommended in all patients for whom the required mAs does not exceed maximum X-ray tube output.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22527361     DOI: 10.1007/s10140-012-1046-z

Source DB:  PubMed          Journal:  Emerg Radiol        ISSN: 1070-3004


  32 in total

Review 1.  Intravenous contrast medium administration and scan timing at CT: considerations and approaches.

Authors:  Kyongtae T Bae
Journal:  Radiology       Date:  2010-07       Impact factor: 11.105

2.  CT angiography of pulmonary arteries to detect pulmonary embolism: improvement of vascular enhancement with low kilovoltage settings.

Authors:  Claudia Schueller-Weidekamm; Cornelia M Schaefer-Prokop; Michael Weber; Christian J Herold; Mathias Prokop
Journal:  Radiology       Date:  2006-12       Impact factor: 11.105

Review 3.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

Review 4.  State of the art: technologies for computed tomography dose reduction.

Authors:  Martin L D Gunn; Jennifer R Kohr
Journal:  Emerg Radiol       Date:  2009-11-20

5.  CT dose index and patient dose: they are not the same thing.

Authors:  Cynthia H McCollough; Shuai Leng; Lifeng Yu; Dianna D Cody; John M Boone; Michael F McNitt-Gray
Journal:  Radiology       Date:  2011-05       Impact factor: 11.105

6.  Comparison of different body size parameters for individual dose adaptation in body CT of adults.

Authors:  Jan Menke
Journal:  Radiology       Date:  2005-08       Impact factor: 11.105

7.  Eighty-peak kilovoltage 16-channel multidetector computed tomography and reduced contrast-medium doses tailored to body weight to diagnose pulmonary embolism in azotaemic patients.

Authors:  Fredrik Holmquist; Ulf Nyman
Journal:  Eur Radiol       Date:  2006-01-27       Impact factor: 5.315

Review 8.  Techniques and applications of automatic tube current modulation for CT.

Authors:  Mannudeep K Kalra; Michael M Maher; Thomas L Toth; Bernhard Schmidt; Bryan L Westerman; Hugh T Morgan; Sanjay Saini
Journal:  Radiology       Date:  2004-10-21       Impact factor: 11.105

9.  Dose to radiosensitive organs during routine chest CT: effects of tube current modulation.

Authors:  Erin Angel; Nazanin Yaghmai; Cecilia Matilda Jude; John J DeMarco; Christopher H Cagnon; Jonathan G Goldin; Cynthia H McCollough; Andrew N Primak; Dianna D Cody; Donna M Stevens; Michael F McNitt-Gray
Journal:  AJR Am J Roentgenol       Date:  2009-11       Impact factor: 3.959

10.  Recurrent CT, cumulative radiation exposure, and associated radiation-induced cancer risks from CT of adults.

Authors:  Aaron Sodickson; Pieter F Baeyens; Katherine P Andriole; Luciano M Prevedello; Richard D Nawfel; Richard Hanson; Ramin Khorasani
Journal:  Radiology       Date:  2009-04       Impact factor: 11.105

View more
  13 in total

Review 1.  Communicating radiation risk to patients and referring physicians in the emergency department setting.

Authors:  Jeffrey Y Shyu; Aaron D Sodickson
Journal:  Br J Radiol       Date:  2016-01-11       Impact factor: 3.039

2.  Incidental findings detection using low tube potential for CT pulmonary angiography.

Authors:  Kanako K Kumamaru; Frank J Rybicki; Rachna Madan; Ritu Gill; Nicole Wake; Andetta R Hunsaker
Journal:  Int J Cardiovasc Imaging       Date:  2014-08-01       Impact factor: 2.357

3.  High-pitch computed tomography pulmonary angiography with iterative reconstruction at 80 kVp and 20 mL contrast agent volume.

Authors:  Guang Ming Lu; Song Luo; Felix G Meinel; Andrew D McQuiston; Chang Sheng Zhou; Xiang Kong; Yan E Zhao; Ling Zheng; U Joseph Schoepf; Long Jiang Zhang
Journal:  Eur Radiol       Date:  2014-08-07       Impact factor: 5.315

4.  Attenuation-based kV pair selection in dual source dual energy computed tomography angiography of the chest: impact on radiation dose and image quality.

Authors:  Rahul D Renapurkar; Andrew Primak; Joseph Azok; Jason Lempel; Yasmeen Tandon; Jennifer Bullen; Frank Dong; Wadih Karim; Ruffin Graham
Journal:  Eur Radiol       Date:  2017-01-13       Impact factor: 5.315

Review 5.  Tailoring protocols for chest CT applications: when and how?

Authors:  Roberto Iezzi; Anna Rita Larici; Paola Franchi; Riccardo Marano; Nicola Magarelli; Alessandro Posa; Biagio Merlino; Riccardo Manfredi; Cesare Colosimo
Journal:  Diagn Interv Radiol       Date:  2017 Nov-Dec       Impact factor: 2.630

6.  Evaluation of CTPA interpreted as limited in pregnant patients suspected for pulmonary embolism.

Authors:  S L Cohen; J Wang; M Mankerian; C Feizullayeva; J A McCandlish; D Barnaby; P Sanelli; T McGinn
Journal:  Emerg Radiol       Date:  2019-12-07

Review 7.  Computed tomography of acute pulmonary embolism: state-of-the-art.

Authors:  Long Jiang Zhang; Guang Ming Lu; Felix G Meinel; Andrew D McQuiston; James G Ravenel; U Joseph Schoepf
Journal:  Eur Radiol       Date:  2015-03-13       Impact factor: 5.315

8.  Internal calibration for opportunistic computed tomography muscle density analysis.

Authors:  Ainsley C J Smith; Justin J Tse; Tadiwa H Waungana; Kirsten N Bott; Michael T Kuczynski; Andrew S Michalski; Steven K Boyd; Sarah L Manske
Journal:  PLoS One       Date:  2022-10-17       Impact factor: 3.752

9.  High pitch, low voltage dual source CT pulmonary angiography: assessment of image quality and diagnostic acceptability with hybrid iterative reconstruction.

Authors:  Patrick D McLaughlin; T Liang; M Homiedan; L J Louis; T W O'Connell; Karl Krzymyk; S Nicolaou; J R Mayo
Journal:  Emerg Radiol       Date:  2014-07-04

10.  High-Pitch CT Pulmonary Angiography in Third Generation Dual-Source CT: Image Quality in an Unselected Patient Population.

Authors:  Bastian O Sabel; Kristijan Buric; Nora Karara; Kolja M Thierfelder; Julien Dinkel; Wieland H Sommer; Felix G Meinel
Journal:  PLoS One       Date:  2016-02-12       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.