Literature DB >> 17136378

MDCT for suspected pulmonary embolism: multi-institutional survey of 16-MDCT data acquisition protocols.

Pamela T Johnson1, David Naidich, Elliot K Fishman.   

Abstract

The purpose of this study was to determine the extent to which a consensus exists on multidetector row computed tomography (MDCT) protocol parameters for suspected pulmonary embolism (PE). In August of 2004, a questionnaire addressing a number of body MDCT protocols was mailed to 99 fellows of the Society of Computed Body Tomography, representing a total of 46 institutions. In May 2005, this was followed up with a second mailing. The survey requested details pertaining to protocols for the most advanced MDCT scanner in the department. The overall survey response rate of 37% (17/46) yielded 15 protocols for 16-MDCT imaging of suspected PE. This data was tabulated and revealed a consensus for the use of bolus tracking, rapid contrast infusion, caudo-cranial scanning, the narrowest detector row collimation, and thin (<2 mm) reconstruction sections. However, contrast infusion timing, contrast concentration, and implementation of radiation dose modulation were variable. This compilation of protocols reflects recently published studies advocating the use of narrow acquisition collimation and reconstruction sections for MDCT of suspected PE. Future studies are necessary to elucidate the optimal intravenous contrast infusion parameters and further assess the efficacy of reduced radiation dose protocols.

Entities:  

Mesh:

Year:  2006        PMID: 17136378     DOI: 10.1007/s10140-006-0547-z

Source DB:  PubMed          Journal:  Emerg Radiol        ISSN: 1070-3004


  30 in total

1.  Consensus on current clinical practice of virtual colonoscopy.

Authors:  Matthew A Barish; Jorge A Soto; Joseph T Ferrucci
Journal:  AJR Am J Roentgenol       Date:  2005-03       Impact factor: 3.959

2.  MDCT angiography of the pulmonary arteries: influence of iodine flow concentration on vessel attenuation and visualization.

Authors:  Helmut Schoellnast; Hannes A Deutschmann; Gerald A Fritz; Uwe Stessel; Gottfried J Schaffler; Manfred Tillich
Journal:  AJR Am J Roentgenol       Date:  2005-06       Impact factor: 3.959

3.  Diagnosing pulmonary embolism with four-detector row helical CT: prospective evaluation of 216 outpatients and inpatients.

Authors:  Marie Pierre Revel; David Petrover; Anne Hernigou; Catherine Lefort; Guy Meyer; Guy Frija
Journal:  Radiology       Date:  2005-01       Impact factor: 11.105

4.  Detection of pulmonary embolism using 16-slice multidetector-row computed tomography: evaluation of different image reconstruction parameters.

Authors:  Martin Heuschmid; Carolin Mann; Oliver Luz; Andreas H Mahnken; Anja Reimann; Claus D Claussen; Andreas F Kopp
Journal:  J Comput Assist Tomogr       Date:  2006 Jan-Feb       Impact factor: 1.826

5.  Peripheral pulmonary arteries: how far in the lung does multi-detector row spiral CT allow analysis?

Authors:  B Ghaye; D Szapiro; I Mastora; V Delannoy; A Duhamel; J Remy; M Remy-Jardin
Journal:  Radiology       Date:  2001-06       Impact factor: 11.105

6.  The effect of single-detector CT versus MDCT on clinical outcomes in patients with suspected acute pulmonary embolism and negative results on CT pulmonary angiography.

Authors:  John David Prologo; Robert C Gilkeson; Mireya Diaz; Matthew Cummings
Journal:  AJR Am J Roentgenol       Date:  2005-04       Impact factor: 3.959

7.  Eighty-peak kilovoltage 16-channel multidetector computed tomography and reduced contrast-medium doses tailored to body weight to diagnose pulmonary embolism in azotaemic patients.

Authors:  Fredrik Holmquist; Ulf Nyman
Journal:  Eur Radiol       Date:  2006-01-27       Impact factor: 5.315

8.  Multidetector-row computed tomography in suspected pulmonary embolism.

Authors:  Arnaud Perrier; Pierre-Marie Roy; Olivier Sanchez; Grégoire Le Gal; Guy Meyer; Anne-Laurence Gourdier; Alain Furber; Marie-Pierre Revel; Nigel Howarth; Alain Davido; Henri Bounameaux
Journal:  N Engl J Med       Date:  2005-04-28       Impact factor: 91.245

9.  Pulmonary embolism: optimization of small pulmonary artery visualization at multi-detector row CT.

Authors:  Smita Patel; Ella A Kazerooni; Philip N Cascade
Journal:  Radiology       Date:  2003-05       Impact factor: 11.105

10.  Evaluation of small pulmonary arteries by 16-slice multidetector computed tomography: Optimum slab thickness in condensing transaxial images converted into maximum intensity projection images.

Authors:  Yeon Joo Jeong; Kyung Soo Lee; Young Cheol Yoon; Tae Sung Kim; Myung Jin Chung; Seonwoo Kim
Journal:  J Comput Assist Tomogr       Date:  2004 Mar-Apr       Impact factor: 1.826

View more
  4 in total

Review 1.  Are intravenous injections of contrast media really less nephrotoxic than intra-arterial injections?

Authors:  Ulf Nyman; Torsten Almén; Bo Jacobsson; Peter Aspelin
Journal:  Eur Radiol       Date:  2012-02-04       Impact factor: 5.315

2.  Iodine contrast iso-attenuating with diagnostic gadolinium doses in CTA and angiography results in ultra-low iodine doses. A way to avoid both CIN and NSF in azotemic patients?

Authors:  Ulf Nyman; Barbara Elmståhl; Håkan Geijer; Peter Leander; Torsten Almén; Mats Nilsson
Journal:  Eur Radiol       Date:  2010-08-29       Impact factor: 5.315

3.  Ultralow contrast medium doses at CT to diagnose pulmonary embolism in patients with moderate to severe renal impairment: a feasibility study.

Authors:  Mattias Kristiansson; Fredrik Holmquist; Ulf Nyman
Journal:  Eur Radiol       Date:  2009-12-24       Impact factor: 5.315

Review 4.  Radiographic contrast-media-induced acute kidney injury: pathophysiology and prophylactic strategies.

Authors:  Umar Sadat
Journal:  ISRN Radiol       Date:  2013-09-16
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.