OBJECTIVE: The purpose of this study was to compare hepatic tumor conspicuity on CT after injection of either 150 mL of contrast material or 100 mL of contrast material plus a 50-mL saline chaser. SUBJECTS AND METHODS: We evaluated 86 hypoattenuating liver metastases in 26 patients. Patients underwent CT in two sessions separated by a mean of 85 days: one time with 150 mL of contrast material and the other time with 100 mL of contrast material followed by a 50-mL saline chaser. The order of the sessions was randomized. Contrast material was administered via power injector and matched for injection rate and delay time. Attenuation values were obtained from normal liver tissue and metastases and from the spleen, kidney, aorta, and inferior vena cava. RESULTS: The 150 mL dose of contrast material caused slightly greater liver and tumor attenuation than 100 mL of contrast material with a chaser (mean hepatic attenuation, 95.6 vs 89.8 H, respectively; p < 0.03, paired t test; mean tumor attenuation, 53.2 vs 49.1 H, respectively; r = 0.71, p = 0.09). The difference in conspicuity of liver lesions was slightly greater with 150 mL than with 100 mL with a chaser (46.8 H vs 44.2 H; r = 0.46, p = 0.08, paired t test), but was of doubtful clinical significance (2.6 H). Kidney, spleen, and vascular structures enhanced more with 150 mL than with 100 mL and a chaser. CONCLUSION: Using 100 mL of contrast material and a saline chaser did not result in a meaningful difference in liver parenchyma attenuation or lesion conspicuity compared with using 150 mL of contrast medium alone. Routine use of a chaser for abdominal CT may yield cost savings and a decreased risk of contrast nephropathy.
RCT Entities:
OBJECTIVE: The purpose of this study was to compare hepatic tumor conspicuity on CT after injection of either 150 mL of contrast material or 100 mL of contrast material plus a 50-mL saline chaser. SUBJECTS AND METHODS: We evaluated 86 hypoattenuating liver metastases in 26 patients. Patients underwent CT in two sessions separated by a mean of 85 days: one time with 150 mL of contrast material and the other time with 100 mL of contrast material followed by a 50-mL saline chaser. The order of the sessions was randomized. Contrast material was administered via power injector and matched for injection rate and delay time. Attenuation values were obtained from normal liver tissue and metastases and from the spleen, kidney, aorta, and inferior vena cava. RESULTS: The 150 mL dose of contrast material caused slightly greater liver and tumor attenuation than 100 mL of contrast material with a chaser (mean hepatic attenuation, 95.6 vs 89.8 H, respectively; p < 0.03, paired t test; mean tumor attenuation, 53.2 vs 49.1 H, respectively; r = 0.71, p = 0.09). The difference in conspicuity of liver lesions was slightly greater with 150 mL than with 100 mL with a chaser (46.8 H vs 44.2 H; r = 0.46, p = 0.08, paired t test), but was of doubtful clinical significance (2.6 H). Kidney, spleen, and vascular structures enhanced more with 150 mL than with 100 mL and a chaser. CONCLUSION: Using 100 mL of contrast material and a saline chaser did not result in a meaningful difference in liver parenchyma attenuation or lesion conspicuity compared with using 150 mL of contrast medium alone. Routine use of a chaser for abdominal CT may yield cost savings and a decreased risk of contrast nephropathy.
Authors: Filippo Cademartiri; Nico Mollet; Aad van der Lugt; Koen Nieman; Peter M T Pattynama; Pim J de Feyter; Gabriel P Krestin Journal: Eur Radiol Date: 2003-12-19 Impact factor: 5.315
Authors: Dae Young Yoon; Su Yeon You; Chul Soon Choi; Suk Ki Chang; Eun Joo Yun; Young Lan Seo; Sang Joon Park; Yu-Jin Lee; Jeung Hee Moon; Young-Soo Rho; Jin-Hwan Kim Journal: Neuroradiology Date: 2006-09-15 Impact factor: 2.804
Authors: Sebastian T Schindera; Rendon C Nelson; Laurens Howle; Eli Nichols; David M DeLong; Elmar M Merkle Journal: Eur Radiol Date: 2008-03-20 Impact factor: 5.315
Authors: Martin G Wagner; Sarvesh Periyasamy; Colin Longhurst; Matthew J McLachlan; Joseph F Whitehead; Michael A Speidel; Paul F Laeseke Journal: Med Phys Date: 2021-09-04 Impact factor: 4.506