Literature DB >> 16011316

Evaluation of fully 3-D emission mammotomography with a compact cadmium zinc telluride detector.

Caryl N Brzymialkiewicz1, Martin P Tornai, Randolph L McKinley, James E Bowsher.   

Abstract

A compact, dedicated cadmium zinc telluride (CZT) gamma camera coupled with a fully three-dimensional (3-D) acquisition system may serve as a secondary diagnostic tool for volumetric molecular imaging of breast cancers, particularly in cases when mammographic findings are inconclusive. The developed emission mammotomography system comprises a medium field-of-view, quantized CZT detector and 3-D positioning gantry. The intrinsic energy resolution, sensitivity and spatial resolution of the detector are evaluated with Tc-99m (140 keV) filled flood sources, capillary line sources, and a 3-D frequency-resolution phantom. To mimic realistic human pendant, uncompressed breast imaging, two different phantom shapes of an average sized breast, and three different lesion diameters are imaged to evaluate the system for 3-D mammotomography. Acquisition orbits not possible with conventional emission, or transmission, systems are designed to optimize the viewable breast volume while improving sampling of the breast and anterior chest wall. Complications in camera positioning about the patient necessitate a compromise in these two orbit design criteria. Image quality is evaluated with signal-to-noise ratios and contrasts of the lesions, both with and without additional torso phantom background. Reconstructed results indicate that 3-D mammotomography, incorporating a compact CZT detector, is a promising, dedicated breast imaging technique for visualization of tumors < 1 cm in diameter. Additionally, there are no outstanding trajectories that consistently yield optimized quantitative lesion imaging parameters. Qualitatively, imaging breasts with realistic torso backgrounds (out-of-field activity) substantially alters image characteristics and breast morphology unless orbits which improve sampling are utilized. In practice, the sampling requirement may be less strict than initially anticipated.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16011316      PMCID: PMC4450799          DOI: 10.1109/tmi.2005.852501

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  17 in total

1.  Performance of a PSPMT based detector for scintimammography.

Authors:  M B Williams; M B Williams; A R Goode; V Galbis-Reig; S Majewski; A G Weisenberger; R Wojcik
Journal:  Phys Med Biol       Date:  2000-03       Impact factor: 3.609

2.  180 degree pinhole SPET with a tilted detector and OS-EM reconstruction: phantom studies and potential clinical applications.

Authors:  A Seret; M Defrise; D Blocklet
Journal:  Eur J Nucl Med       Date:  2001-10-03

3.  Emission tuned-aperture computed tomography: a novel approach to scintimammography.

Authors:  F H Fahey; K L Grow; R L Webber; B A Harkness; E Bayram; P F Hemler
Journal:  J Nucl Med       Date:  2001-07       Impact factor: 10.057

4.  Mammotomography with pinhole incomplete circular orbit SPECT.

Authors:  Martin P Tornai; James E Bowsher; Ronald J Jaszczak; Brett C Pieper; Kim L Greer; Patricia H Hardenbergh; R Edward Coleman
Journal:  J Nucl Med       Date:  2003-04       Impact factor: 10.057

5.  Evaluation of a small cadmium zinc telluride detector for scintimammography.

Authors:  Bryon Mueller; Michael K O'Connor; Ira Blevis; Deborah J Rhodes; Robin Smith; Douglas A Collins; Stephen W Phillips
Journal:  J Nucl Med       Date:  2003-04       Impact factor: 10.057

6.  High-resolution scintimammography improves the accuracy of technetium-99m methoxyisobutylisonitrile scintimammography: use of a new dedicated gamma camera.

Authors:  F Scopinaro; R Pani; G De Vincentis; A Soluri; R Pellegrini; L M Porfiri
Journal:  Eur J Nucl Med       Date:  1999-10

7.  Breast tumour imaging using incomplete circular orbit pinhole SPET: a phantom study.

Authors:  C Scarfone; R J Jaszczak; J Li; M S Soo; M F Smith; K L Greer; R E Coleman
Journal:  Nucl Med Commun       Date:  1997-11       Impact factor: 1.690

8.  Scintimammography with dedicated breast camera detects and localizes occult carcinoma.

Authors:  Leonard R Coover; Gina Caravaglia; Phyllis Kuhn
Journal:  J Nucl Med       Date:  2004-04       Impact factor: 10.057

9.  Technetium-99m-sestamibi uptake in breast tumor and associated lymph nodes.

Authors:  J Maublant; M de Latour; D Mestas; A Clemenson; S Charrier; V Feillel; G Le Bouedec; P Kaufmann; J Dauplat; A Veyre
Journal:  J Nucl Med       Date:  1996-06       Impact factor: 10.057

10.  Technetium-99m hexakis 2-methoxyisobutyl isonitrile: human biodistribution, dosimetry, safety, and preliminary comparison to thallium-201 for myocardial perfusion imaging.

Authors:  F J Wackers; D S Berman; J Maddahi; D D Watson; G A Beller; H W Strauss; C A Boucher; M Picard; B L Holman; R Fridrich
Journal:  J Nucl Med       Date:  1989-03       Impact factor: 10.057

View more
  17 in total

Review 1.  Dynamic single photon emission computed tomography--basic principles and cardiac applications.

Authors:  Grant T Gullberg; Bryan W Reutter; Arkadiusz Sitek; Jonathan S Maltz; Thomas F Budinger
Journal:  Phys Med Biol       Date:  2010-09-22       Impact factor: 3.609

2.  Characterization of simulated incident scatter and the impact on quantification in dedicated breast single-photon emission computed tomography.

Authors:  Steve D Mann; Martin P Tornai
Journal:  J Med Imaging (Bellingham)       Date:  2015-09-21

3.  Performance of dedicated emission mammotomography for various breast shapes and sizes.

Authors:  C N Brzymialkiewicz; M P Tornai; R L McKinley; S J Cutler; J E Bowsher
Journal:  Phys Med Biol       Date:  2006-09-19       Impact factor: 3.609

4.  Preliminary evaluation of a novel energy-resolved photon-counting gamma ray detector.

Authors:  L-J Meng; J W Tan; K Spartiotis; T Schulman
Journal:  Nucl Instrum Methods Phys Res A       Date:  2009-03-19       Impact factor: 1.455

Review 5.  The origins of SPECT and SPECT/CT.

Authors:  Brian F Hutton
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-11-12       Impact factor: 9.236

Review 6.  Technological development and advances in single-photon emission computed tomography/computed tomography.

Authors:  Youngho Seo; Carina Mari; Bruce H Hasegawa
Journal:  Semin Nucl Med       Date:  2008-05       Impact factor: 4.446

7.  Characterizing the contribution of cardiac and hepatic uptake in dedicated breast SPECT using tilted trajectories.

Authors:  K L Perez; S J Cutler; P Madhav; M P Tornai
Journal:  Phys Med Biol       Date:  2010-07-30       Impact factor: 3.609

8.  Implementation and evaluation of an expectation maximization reconstruction algorithm for gamma emission breast tomosynthesis.

Authors:  Zongyi Gong; Kelly Klanian; Tushita Patel; Olivia Sullivan; Mark B Williams
Journal:  Med Phys       Date:  2012-12       Impact factor: 4.071

9.  Is SPECT or CT Based Attenuation Correction More Quantitatively Accurate for Dedicated Breast SPECT Acquired with Non-Traditional Trajectories?

Authors:  Kristy L Perez; Steve D Mann; Jan H Pachon; Priti Madhav; Martin P Tornai
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2010 Oct-Nov

Review 10.  Breast cancer imaging: a perspective for the next decade.

Authors:  Andrew Karellas; Srinivasan Vedantham
Journal:  Med Phys       Date:  2008-11       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.