In this paper, we present the design and preliminary performance evaluation of a novel energy-resolved photon-counting (ERPC) detector for gamma ray imaging applications. The prototype ERPC detector has an active area of 4.4 cm × 4.4 cm, which is pixelated into 128 × 128 square pixels with a pitch size of 350 µm × 350µm. The current detector consists of multiple detector hybrids, each with a CdTe crystal of 1.1 cm × 2.2 cm × 1 mm, bump-bonded onto a custom-designed application-specific integrated circuit (ASIC). The ERPC ASIC has 2048 readout channels arranged in a 32 × 64 array. Each channel is equipped with pre- and shaping-amplifiers, a discriminator, peak/hold circuitry and an analog-to-digital converter (ADC) for digitizing the signal amplitude. In order to compensate for the pixel-to-pixel variation, two 8-bit digital-to-analog converters (DACs) are implemented into each channel for tuning the gain and offset. The ERPC detector is designed to offer a high spatial resolution, a wide dynamic range of 12-200 keV and a good energy resolution of 3-4 keV. The hybrid detector configuration provides a flexible detection area that can be easily tailored for different imaging applications. The intrinsic performance of a prototype ERPC detector was evaluated with various gamma ray sources, and the results are presented.

Entities:  

Keywords:  CdTe; Energy-resolved photon counting; Gamma ray imaging

Year:  2009        PMID: 28260825      PMCID: PMC5333787          DOI: 10.1016/j.nima.2009.02.043

Source DB:  PubMed          Journal:  Nucl Instrum Methods Phys Res A        ISSN: 0168-9002            Impact factor:   1.455


  5 in total

1.  Analytic determination of the pinhole collimator's point-spread function and RMS resolution with penetration.

Authors:  S D Metzler; J E Bowsher; K L Greer; R J Jaszczak
Journal:  IEEE Trans Med Imaging       Date:  2002-08       Impact factor: 10.048

2.  Optimal number of pinholes in multi-pinhole SPECT for mouse brain imaging--a simulation study.

Authors:  Zixiong Cao; Girish Bal; Roberto Accorsi; Paul D Acton
Journal:  Phys Med Biol       Date:  2005-09-21       Impact factor: 3.609

3.  Evaluation of fully 3-D emission mammotomography with a compact cadmium zinc telluride detector.

Authors:  Caryl N Brzymialkiewicz; Martin P Tornai; Randolph L McKinley; James E Bowsher
Journal:  IEEE Trans Med Imaging       Date:  2005-07       Impact factor: 10.048

4.  An Ultrahigh Resolution SPECT System for I-125 Mouse Brain Imaging Studies.

Authors:  L J Meng; G Fu; E J Roy; B Suppe; C T Chen
Journal:  Nucl Instrum Methods Phys Res A       Date:  2009-03-01       Impact factor: 1.455

5.  SemiSPECT: a small-animal single-photon emission computed tomography (SPECT) imager based on eight cadmium zinc telluride (CZT) detector arrays.

Authors:  Hyunki Kim; Lars R Furenlid; Michael J Crawford; Donald W Wilson; H Bradford Barber; Todd E Peterson; William C J Hunter; Zhonglin Liu; James M Woolfenden; Harrison H Barrett
Journal:  Med Phys       Date:  2006-02       Impact factor: 4.071

  5 in total
  5 in total

1.  MRC-SPECT: A sub-500 μm resolution MR-compatible SPECT system for simultaneous dual-modality study of small animals.

Authors:  Liang Cai; Xiaochun Lai; Zengming Shen; Chin-Tu Chen; Ling-Jian Meng
Journal:  Nucl Instrum Methods Phys Res A       Date:  2014-01-11       Impact factor: 1.455

2.  Effect of CZT system characteristics on Compton scatter event recovery.

Authors:  Sheng Yang; Mohan Li; Michael Reed; James Hugg; Henry Chen; Shiva Abbaszadeh
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2019-05-06

3.  Simulation study of the second-generation MR-compatible SPECT system based on the inverted compound-eye gamma camera design.

Authors:  Xiaochun Lai; Ling-Jian Meng
Journal:  Phys Med Biol       Date:  2018-02-12       Impact factor: 3.609

4.  Hybrid Pixel-Waveform (HPWF) Enabled CdTe Detectors for Small Animal Gamma-Ray Imaging Applications.

Authors:  A Groll; K Kim; H Bhatia; J C Zhang; J H Wang; Z M Shen; L Cai; J Dutta; Q Li; L J Meng
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2016-11-01

5.  A novel depth-of-interaction rebinning strategy for ultrahigh resolution PET.

Authors:  Kyungsang Kim; Joyita Dutta; Andrew Groll; Georges El Fakhri; Ling-Jian Meng; Quanzheng Li
Journal:  Phys Med Biol       Date:  2018-08-14       Impact factor: 3.609

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.