Literature DB >> 24218098

The origins of SPECT and SPECT/CT.

Brian F Hutton1.   

Abstract

Single photon emission computed tomography (SPECT) has a long history of development since its initial demonstration by Kuhl and Edwards in 1963. Although clinical utility has been dominated by the rotating gamma camera, there have been many technological innovations with the recent popularity of organ-specific dedicated SPECT systems. The combination of SPECT and CT evolved from early transmission techniques used for attenuation correction with the initial commercial systems predating the release of PET/CT. The development and acceptance of SPECT/CT has been relatively slow with continuing debate as to what cost/performance ratio is justified. Increasingly, fully diagnostic CT is combined with SPECT so as to facilitate optimal clinical utility.

Mesh:

Year:  2013        PMID: 24218098     DOI: 10.1007/s00259-013-2606-5

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


  71 in total

1.  C-SPECT - a Clinical Cardiac SPECT/Tct Platform: Design Concepts and Performance Potential.

Authors:  Wei Chang; Caesar E Ordonez; Haoning Liang; Yusheng Li; Jingai Liu
Journal:  IEEE Trans Nucl Sci       Date:  2009-10-06       Impact factor: 1.679

2.  Recent technologic advances in nuclear cardiology.

Authors:  James A Patton; Piotr J Slomka; Guido Germano; Daniel S Berman
Journal:  J Nucl Cardiol       Date:  2007-07       Impact factor: 5.952

3.  Longitudinal tomographic radioisotopic imaging with a scintillation camera: theoretical considerations of a new method.

Authors:  J G McAfee; J M Mozley; E P Stabler
Journal:  J Nucl Med       Date:  1969-10       Impact factor: 10.057

4.  The Humongotron--a scintillation-camera transaxial tomograph.

Authors:  J W Keyes; N Orlandea; W J Heetderks; P F Leonard; W L Rogers
Journal:  J Nucl Med       Date:  1977-04       Impact factor: 10.057

5.  Absolute quantitation of radiotracer uptake in the lungs using a gamma camera.

Authors:  D J Macey; R Marshall
Journal:  J Nucl Med       Date:  1982-08       Impact factor: 10.057

6.  An electronically collimated gamma camera for single photon emission computed tomography. Part I: Theoretical considerations and design criteria.

Authors:  M Singh
Journal:  Med Phys       Date:  1983 Jul-Aug       Impact factor: 4.071

7.  HEADTOME: a hybrid emission tomograph for single photon and positron emission imaging of the brain.

Authors:  I Kanno; K Uemura; S Miura; Y Miura
Journal:  J Comput Assist Tomogr       Date:  1981-04       Impact factor: 1.826

8.  Transmission scanning: a useful adjunct to conventional emission scanning for accurately keying isotope deposition to radiographic anatomy.

Authors:  D E Kuhl; J Hale; W L Eaton
Journal:  Radiology       Date:  1966-08       Impact factor: 11.105

9.  Instrumentation Design for Adaptive SPECT/CT.

Authors:  Jared W Moore; Lars R Furenlid; Harrison H Barrett
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2008-10

10.  Phantom evaluation of a cardiac SPECT/VCT system that uses a common set of solid-state detectors for both emission and transmission scans.

Authors:  Chuanyong Bai; Richard Conwell; Joel Kindem; Hetal Babla; Mike Gurley; Romer De Los Santos; Rex Old; Randy Weatherhead; Samia Arram; Jamshid Maddahi
Journal:  J Nucl Cardiol       Date:  2010-02-19       Impact factor: 5.952

View more
  12 in total

1.  Dual isotope simultaneous imaging to evaluate the effects of intracoronary bone marrow-derived mesenchymal stem cells on perfusion and metabolism in canines with acute myocardial infarction.

Authors:  Linjun Hao; Jin Hao; Wei Fang; Chunlei Han; Kaixiu Zhang; Xuemei Wang
Journal:  Biomed Rep       Date:  2015-05-27

Review 2.  Sentinel lymph node biopsy in oral and oropharyngeal squamous cell carcinoma: current status and unresolved challenges.

Authors:  Christina Bluemel; Domenico Rubello; Patrick M Colletti; Remco de Bree; Ken Herrmann
Journal:  Eur J Nucl Med Mol Imaging       Date:  2015-04-28       Impact factor: 9.236

3.  A sum-modified-Laplacian and sparse representation based multimodal medical image fusion in Laplacian pyramid domain.

Authors:  Xiaoqing Li; Xuming Zhang; Mingyue Ding
Journal:  Med Biol Eng Comput       Date:  2019-08-14       Impact factor: 2.602

Review 4.  Interdigitating dendritic cell sarcoma: analysis of two original extra-nodal cases and review of literature.

Authors:  Jiayu Zhou; Qingling Li; Xiaodan Fu; Deyun Feng; Keda Yang; Junpu Wang
Journal:  Virchows Arch       Date:  2022-04-09       Impact factor: 4.064

5.  Let's embrace optical imaging: a growing branch on the clinical molecular imaging tree.

Authors:  Milou E Noltes; Gooitzen M van Dam; Wouter B Nagengast; Pieter J van der Zaag; Riemer H J A Slart; Wiktor Szymanski; Schelto Kruijff; Rudi A J O Dierckx
Journal:  Eur J Nucl Med Mol Imaging       Date:  2021-12       Impact factor: 9.236

Review 6.  Application of Advanced Imaging Modalities in Veterinary Medicine: A Review.

Authors:  Dagmawi Yitbarek; Gashaw Getaneh Dagnaw
Journal:  Vet Med (Auckl)       Date:  2022-05-31

7.  Fusion of freehand SPECT and ultrasound: First experience in preoperative localization of sentinel lymph nodes.

Authors:  Christina Bluemel; Gonca Safak; Andreas Cramer; Achim Wöckel; Anja Gesierich; Elena Hartmann; Jan-Stefan Schmid; Franz Kaiser; Andreas K Buck; Ken Herrmann
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-06-17       Impact factor: 9.236

Review 8.  Current Applications for Nuclear Medicine Imaging in Pulmonary Disease.

Authors:  Joanna E Kusmirek; Josiah D Magnusson; Scott B Perlman
Journal:  Curr Pulmonol Rep       Date:  2020-07-22

9.  The contribution of Medical Physics to Nuclear Medicine: looking back - a physicist's perspective.

Authors:  Brian F Hutton
Journal:  EJNMMI Phys       Date:  2014-05-01

10.  CT-Based Attenuation Correction in Brain SPECT/CT Can Improve the Lesion Detectability of Voxel-Based Statistical Analyses.

Authors:  Hiroki Kato; Eku Shimosegawa; Koichi Fujino; Jun Hatazawa
Journal:  PLoS One       Date:  2016-07-21       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.