Literature DB >> 9423209

Breast tumour imaging using incomplete circular orbit pinhole SPET: a phantom study.

C Scarfone1, R J Jaszczak, J Li, M S Soo, M F Smith, K L Greer, R E Coleman.   

Abstract

Improvements in 99Tcm-sestamibi breast lesion visualization using single photon emission tomography (SPET) may help define the clinical role of this technique alongside X-ray mammography in the diagnosis and management of breast cancer. Pinhole SPET offers the advantages of high resolution and sensitivity when compared to conventional parallel-beam collimation for sources located near the pinhole aperture. In this work, the potential of incomplete (180 degrees) circular orbit (ICO) SPET with pinhole collimation is investigated as a means to visualize small (6.4 and 9.6 mm diameter) spherical simulated tumours, at clinical count densities and tumour-to-background ratios, in a breast phantom. ICO pinhole SPET is compared to complete circular orbit (CCO) pinhole SPET for reference, and planar breast imaging (scintimammography) using parallel-beam and pinhole collimators. A prototype box-shaped pinhole collimator with a 4 mm diameter circular aperture was used to acquire projections of an 890 ml breast phantom both in isolation and mounted on a cylinder filled with a mixture of 99Tcm-pertechnetate and water. A heart phantom containing 99Tcm activity in the myocardium was placed in the cylinder. Simulated tumours containing 99Tcm were placed in the breast phantom and scanned at clinically relevant count densities and scan times with tumour-to-normal tissue concentration ratios of 5.0:1 (9.6 mm sphere) and 7.7:1 (6.4 mm sphere). Phantom data were reconstructed using pinhole filtered backprojection (FBP) and maximum likelihood-expectation maximization (ML-EM). The tumours were not visualized with scintimammography, in which lesion contrast and signal-to-noise were estimated from region of interest analysis to be < 2% and 0.01, respectively. Average (over lesion size and scan time) contrast and signal-to-noise in the ICO (CCO) SPET images were 33% and 1.72 (34% and 1.3), respectively. These values indicate that ICO pinhole SPET has the potential to improve visualization of small (< 10 mm) breast tumours when compared with scintimammography, which may be beneficial for the early classification of cancers of the breast.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9423209     DOI: 10.1097/00006231-199711000-00012

Source DB:  PubMed          Journal:  Nucl Med Commun        ISSN: 0143-3636            Impact factor:   1.690


  4 in total

1.  Analytic Determination of Rectangular-Pinhole Sensitivity With Penetration.

Authors:  Scott D Metzler; Stephen C Moore
Journal:  IEEE Trans Med Imaging       Date:  2019-08-19       Impact factor: 10.048

2.  Evaluation of fully 3-D emission mammotomography with a compact cadmium zinc telluride detector.

Authors:  Caryl N Brzymialkiewicz; Martin P Tornai; Randolph L McKinley; James E Bowsher
Journal:  IEEE Trans Med Imaging       Date:  2005-07       Impact factor: 10.048

3.  Body contour 180 degrees pinhole SPET with or without tilted detector: a phantom study.

Authors:  Alain Seret; David Flérès; Olivier Firket; Michel Defrise
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-06-17       Impact factor: 9.236

Review 4.  Advances in pinhole and multi-pinhole collimators for single photon emission computed tomography imaging.

Authors:  Jalil Pirayesh Islamian; AhmadReza Azazrm; Babak Mahmoudian; Esmail Gharapapagh
Journal:  World J Nucl Med       Date:  2015 Jan-Apr
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.