Literature DB >> 20671354

Characterizing the contribution of cardiac and hepatic uptake in dedicated breast SPECT using tilted trajectories.

K L Perez1, S J Cutler, P Madhav, M P Tornai.   

Abstract

A small field of view, high resolution gamma camera has been integrated into a dedicated breast, single photon emission computed tomography (SPECT) device. The detector can be flexibly positioned relative to the breast and image beyond the chest wall, allowing the system to capture direct views of the heart and liver. The incomplete sampling of these organs creates artifacts in reconstructed images, complicating lesion detection. To understand the limits imposed on a 3D acquisition trajectory, sequential tilted trajectories at increasing polar tilt are utilized to collect data of anthropomorphic phantoms filled with aqueous (99m)Tc in a clinically realistic concentration ratio. The counts collected per projection between different scans and the SNR, contrast and resolution (FWHM) of two hot lesions were compared. As expected, the counts per projection increased when the camera had direct views of the heart and liver, but remained relatively constant at other angles. The SNR, contrast and FWHM were more affected by the insufficient sampling of the data by the large polar angles than by the cardiac and hepatic activity. An upper bound on polar tilt for each azimuthal position reduces the artifacts in the reconstructed images. Such trajectories were implemented to show artifact-free reconstructed images.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20671354      PMCID: PMC3266057          DOI: 10.1088/0031-9155/55/16/007

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  18 in total

1.  Performance of dedicated emission mammotomography for various breast shapes and sizes.

Authors:  C N Brzymialkiewicz; M P Tornai; R L McKinley; S J Cutler; J E Bowsher
Journal:  Phys Med Biol       Date:  2006-09-19       Impact factor: 3.609

2.  Emission computed tomography.

Authors:  M E Phelps
Journal:  Semin Nucl Med       Date:  1977-10       Impact factor: 4.446

3.  Comparison of small field of view gamma camera systems for scintimammography.

Authors:  Carrie B Hruska; Michael K O'Connor; Douglas A Collins
Journal:  Nucl Med Commun       Date:  2005-05       Impact factor: 1.690

4.  Myocardial perfusion imaging with a new radiotracer, technetium-99m-hexamibi (methoxy isobutyl isonitrile): comparison with thallium-201 imaging.

Authors:  R Taillefer; G Dupras; V Sporn; P Rigo; J Leveille; P Boucher; N Perez-Balino; L L Camin; K A McKusick
Journal:  Clin Nucl Med       Date:  1989-02       Impact factor: 7.794

5.  99Tcm-MIBI scintimammography in 300 consecutive patients: factors that may affect accuracy.

Authors:  A Tofani; R Sciuto; A Semprebene; A Festa; R Pasqualoni; S Giunta; M Mottolese; M Benevolo; C Botti; C L Maini
Journal:  Nucl Med Commun       Date:  1999-12       Impact factor: 1.690

6.  Observer detection limits for a dedicated SPECT breast imaging system.

Authors:  S J Cutler; K L Perez; H X Barnhart; M P Tornai
Journal:  Phys Med Biol       Date:  2010-03-12       Impact factor: 3.609

7.  [Study of myocardial perfusion at rest using technetium Tc 99m methoxy-isobutylisonitrile: comparison with labeled microspheres and thallium 201].

Authors:  G M Santoro; G Bisi; R Sciagrà; D Antoniucci; M T De Cristofaro; E V Dovellini; A Pupi; M Zerauschek; P F Fazzini
Journal:  G Ital Cardiol       Date:  1988-11

8.  Breast-specific gamma imaging as an adjunct imaging modality for the diagnosis of breast cancer.

Authors:  Rachel F Brem; Angelique C Floerke; Jocelyn A Rapelyea; Christine Teal; Tricia Kelly; Vivek Mathur
Journal:  Radiology       Date:  2008-06       Impact factor: 11.105

9.  Technetium-99m-sestamibi uptake in breast tumor and associated lymph nodes.

Authors:  J Maublant; M de Latour; D Mestas; A Clemenson; S Charrier; V Feillel; G Le Bouedec; P Kaufmann; J Dauplat; A Veyre
Journal:  J Nucl Med       Date:  1996-06       Impact factor: 10.057

10.  Scintimammography with dedicated breast camera in unifocal and multifocal/multicentric primary breast cancer detection: a comparative study with SPECT.

Authors:  Angela Spanu; Pierina Cottu; Alessandra Manca; Francesca Chessa; Daniela Sanna; Giuseppe Madeddu
Journal:  Int J Oncol       Date:  2007-08       Impact factor: 5.650

View more
  3 in total

1.  Characterization of simulated incident scatter and the impact on quantification in dedicated breast single-photon emission computed tomography.

Authors:  Steve D Mann; Martin P Tornai
Journal:  J Med Imaging (Bellingham)       Date:  2015-09-21

2.  Towards Quantification of Functional Breast Images Using Dedicated SPECT With Non-Traditional Acquisition Trajectories.

Authors:  Kristy L Perez; Spencer J Cutler; Priti Madhav; Martin P Tornai
Journal:  IEEE Trans Nucl Sci       Date:  2011-10       Impact factor: 1.679

Review 3.  The potential role of dedicated 3D breast CT as a diagnostic tool: review and early clinical examples.

Authors:  Avice M O'Connell; Andrew Karellas; Srinivasan Vedantham
Journal:  Breast J       Date:  2014-09-08       Impact factor: 2.431

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.