Literature DB >> 11734923

180 degree pinhole SPET with a tilted detector and OS-EM reconstruction: phantom studies and potential clinical applications.

A Seret1, M Defrise, D Blocklet.   

Abstract

This study investigated the feasibility of ordered subsets expectation maximisation (OS-EM) reconstruction of pinhole single-photon emission tomography (SPET) acquired with a tilted detector head and a 180 degrees orbit. Phantom and patient data were recorded using a standard single-head camera. Reconstructions were performed using a dedicated OS-EM algorithm. Reconstructed images of line, uniformity and Picker's thyroid phantoms showed that the geometry, physical size and uniformity of the radioactive objects were preserved. For the range of radius corresponding to the patient studies, the measured full-widths at half-maximum lay between 4.90+/-0.25 mm and 6.05+/-0.25 mm. Finally, the gain in resolution associated with the use of the pinhole collimator instead of a parallel-hole collimator was highlighted in a parathyroid exploration and in a shoulder bone study.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11734923     DOI: 10.1007/s002590100629

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  6 in total

Review 1.  The pinhole: gateway to ultra-high-resolution three-dimensional radionuclide imaging.

Authors:  Freek Beekman; Frans van der Have
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-02       Impact factor: 9.236

2.  Will high-resolution/high-sensitivity SPECT ensure that PET is not the only survivor in nuclear medicine during the next decade?

Authors:  Alain Seret
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-01-14       Impact factor: 9.236

3.  Evaluation of fully 3-D emission mammotomography with a compact cadmium zinc telluride detector.

Authors:  Caryl N Brzymialkiewicz; Martin P Tornai; Randolph L McKinley; James E Bowsher
Journal:  IEEE Trans Med Imaging       Date:  2005-07       Impact factor: 10.048

4.  99mTc-MIBI pinhole SPECT in primary hyperparathyroidism: comparison with conventional SPECT, planar scintigraphy and ultrasonography.

Authors:  Thomas Carlier; Aurore Oudoux; Eric Mirallié; Alain Seret; Isabelle Daumy; Christophe Leux; Caroline Bodet-Milin; Françoise Kraeber-Bodéré; Catherine Ansquer
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-10-25       Impact factor: 9.236

5.  Body contour 180 degrees pinhole SPET with or without tilted detector: a phantom study.

Authors:  Alain Seret; David Flérès; Olivier Firket; Michel Defrise
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-06-17       Impact factor: 9.236

Review 6.  Advances in pinhole and multi-pinhole collimators for single photon emission computed tomography imaging.

Authors:  Jalil Pirayesh Islamian; AhmadReza Azazrm; Babak Mahmoudian; Esmail Gharapapagh
Journal:  World J Nucl Med       Date:  2015 Jan-Apr
  6 in total