Literature DB >> 15875193

Influence of high magnetic field strengths and parallel acquisition strategies on image quality in cardiac 2D CINE magnetic resonance imaging: comparison of 1.5 T vs. 3.0 T.

Matthias Gutberlet1, Kerstin Schwinge, Patrick Freyhardt, Birgit Spors, Matthias Grothoff, Timm Denecke, Lutz Lüdemann, Ralph Noeske, Thoralf Niendorf, Roland Felix.   

Abstract

The aim of this paper is to examine signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and image quality of cardiac CINE imaging at 1.5 T and 3.0 T. Twenty volunteers underwent cardiac magnetic resonance imaging (MRI) examinations using a 1.5-T and a 3.0-T scanner. Three different sets of breath-held, electrocardiogram-gated (ECG) CINE imaging techniques were employed, including: (1) unaccelerated SSFP (steady state free precession), (2) accelerated SSFP imaging and (3) gradient-echo-based myocardial tagging. Two-dimensional CINE SSFP at 3.0 T revealed an SNR improvement of 103% and a CNR increase of 19% as compared to the results obtained at 1.5 T. The SNR reduction in accelerated 2D CINE SSFP imaging was larger at 1.5 T (37%) compared to 3.0 T (26%). The mean SNR and CNR increase at 3.0 T obtained for the tagging sequence was 88% and 187%, respectively. At 3.0 T, the duration of the saturation bands persisted throughout the entire cardiac cycle. For comparison, the saturation bands were significantly diminished at 1.5 T during end-diastole. For 2D CINE SSFP imaging, no significant difference in the left ventricular volumetry and in the overall image quality was obtained. For myocardial tagging, image quality was significantly improved at 3.0 T. The SNR reduction in accelerated SSFP imaging was overcompensated by the increase in the baseline SNR at 3.0 T and did not result in any image quality degradation. For cardiac tagging techniques, 3.0 T was highly beneficial, which holds the promise to improve its diagnostic value.

Entities:  

Mesh:

Year:  2005        PMID: 15875193     DOI: 10.1007/s00330-005-2768-z

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  26 in total

1.  Human cardiac imaging at 3 T using phased array coils.

Authors:  R Noeske; F Seifert; K H Rhein; H Rinneberg
Journal:  Magn Reson Med       Date:  2000-12       Impact factor: 4.668

2.  MR Imaging of the heart with cine true fast imaging with steady-state precession: influence of spatial and temporal resolutions on left ventricular functional parameters.

Authors:  Stephan Miller; Orlando P Simonetti; James Carr; Ulrich Kramer; J Paul Finn
Journal:  Radiology       Date:  2002-04       Impact factor: 11.105

3.  Double inversion black-blood fast spin-echo imaging of the human heart: a comparison between 1.5T and 3.0T.

Authors:  Robert L Greenman; John E Shirosky; Robert V Mulkern; Neil M Rofsky
Journal:  J Magn Reson Imaging       Date:  2003-06       Impact factor: 4.813

4.  Ultimate intrinsic signal-to-noise ratio for parallel MRI: electromagnetic field considerations.

Authors:  Michael A Ohliger; Aaron K Grant; Daniel K Sodickson
Journal:  Magn Reson Med       Date:  2003-11       Impact factor: 4.668

5.  Comparison of transthoracic three dimensional echocardiography with magnetic resonance imaging in the assessment of right ventricular volume and mass.

Authors:  M Vogel; M Gutberlet; S Dittrich; N Hosten; P E Lange
Journal:  Heart       Date:  1997-08       Impact factor: 5.994

6.  In vitro validation of phase-contrast flow measurements at 3 T in comparison to 1.5 T: precision, accuracy, and signal-to-noise ratios.

Authors:  Joachim Lotz; Rolf Döker; Ralph Noeske; Meike Schüttert; Roland Felix; Michael Galanski; Matthias Gutberlet; Gerd Peter Meyer
Journal:  J Magn Reson Imaging       Date:  2005-05       Impact factor: 4.813

7.  The intrinsic signal-to-noise ratio in human cardiac imaging at 1.5, 3, and 4 T.

Authors:  H Wen; T J Denison; R W Singerman; R S Balaban
Journal:  J Magn Reson       Date:  1997-03       Impact factor: 2.229

8.  Age- and gender-specific differences in left and right ventricular cardiac function and mass determined by cine magnetic resonance imaging.

Authors:  J Sandstede; C Lipke; M Beer; S Hofmann; T Pabst; W Kenn; S Neubauer; D Hahn
Journal:  Eur Radiol       Date:  2000       Impact factor: 5.315

9.  Fast tracking of cardiac motion using 3D-HARP.

Authors:  Li Pan; Joao A C Lima; Nael F Osman
Journal:  Inf Process Med Imaging       Date:  2003-07

10.  Human heart: tagging with MR imaging--a method for noninvasive assessment of myocardial motion.

Authors:  E A Zerhouni; D M Parish; W J Rogers; A Yang; E P Shapiro
Journal:  Radiology       Date:  1988-10       Impact factor: 11.105

View more
  28 in total

1.  [Myocardial MR tagging: analysis of regional and global myocardial function].

Authors:  U Kramer; A Hennemuth; M Fenchel
Journal:  Radiologe       Date:  2010-06       Impact factor: 0.635

2.  High spatial resolution contrast-enhanced MR angiography of the supraaortic arteries using the quadrature body coil at 3.0T: a feasibility study.

Authors:  Winfried A Willinek; Thomas Bayer; Jürgen Gieseke; Marcus von Falkenhausen; Torsten Sommer; Romhild Hoogeveen; Kai Wilhelm; Horst Urbach; Hans H Schild
Journal:  Eur Radiol       Date:  2006-08-30       Impact factor: 5.315

Review 3.  Advances in MRI tagging techniques for determining regional myocardial strain.

Authors:  Vinay M Pai; Leon Axel
Journal:  Curr Cardiol Rep       Date:  2006-02       Impact factor: 2.931

4.  Higher sensitivity in the detection of inflammatory brain lesions in patients with clinically isolated syndromes suggestive of multiple sclerosis using high field MRI: an intraindividual comparison of 1.5 T with 3.0 T.

Authors:  Mike P Wattjes; Götz G Lutterbey; Michael Harzheim; Jürgen Gieseke; Frank Träber; Luisa Klotz; Thomas Klockgether; Hans H Schild
Journal:  Eur Radiol       Date:  2006-04-29       Impact factor: 5.315

5.  Fast magnetic resonance imaging of the knee using a parallel acquisition technique (mSENSE): a prospective performance evaluation.

Authors:  Karl-Friedrich Kreitner; Bernd Romaneehsen; Frank Krummenauer; Katja Oberholzer; Lars Peter Müller; Christoph Düber
Journal:  Eur Radiol       Date:  2006-05-30       Impact factor: 5.315

Review 6.  Characterization of myocardial viability using MR and CT imaging.

Authors:  Gabriele A Krombach; Thoralf Niendorf; Rolf W Günther; Andreas H Mahnken
Journal:  Eur Radiol       Date:  2007-01-06       Impact factor: 5.315

7.  Myocardial tagging with steady state free precession techniques and semi-automatic postprocessing--impact on diagnostic value.

Authors:  Thorsten R C Johnson; Nicole Bayrhof; Armin Huber; Joost P A Kuijer; Roger Luechinger; Olaf Dietrich; Dietrich Stoevesandt; Dorthe Pedersen; Maximilian F Reiser; Stefan O Schoenberg
Journal:  Eur Radiol       Date:  2007-04-19       Impact factor: 5.315

Review 8.  Muskuloskeletal MR imaging at 3.0 T: current status and future perspectives.

Authors:  Nicolae Bolog; Daniel Nanz; Dominik Weishaupt
Journal:  Eur Radiol       Date:  2006-03-16       Impact factor: 5.315

Review 9.  Cardiac magnetic resonance at high field: promises and problems.

Authors:  Ahmed M Gharib; Abdalla Elagha; Roderic I Pettigrew
Journal:  Curr Probl Diagn Radiol       Date:  2008 Mar-Apr

10.  Intraindividual comparison of myocardial delayed enhancement MR imaging using gadobenate dimeglumine at 1.5 T and 3 T.

Authors:  Bernhard D Klumpp; Joern Sandstede; Klaus P Lodemann; Achim Seeger; Tobias Hoevelborn; Michael Fenchel; Ulrich Kramer; Claus D Claussen; Stephan Miller
Journal:  Eur Radiol       Date:  2008-12-18       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.