Literature DB >> 16733683

Fast magnetic resonance imaging of the knee using a parallel acquisition technique (mSENSE): a prospective performance evaluation.

Karl-Friedrich Kreitner1, Bernd Romaneehsen, Frank Krummenauer, Katja Oberholzer, Lars Peter Müller, Christoph Düber.   

Abstract

The performance of a magnetic resonance (MR) imaging strategy that uses multiple receiver coil elements and integrated parallel imaging techniques (iPAT) in traumatic and degenerative disorders of the knee and to compare this technique with a standard MR imaging protocol was evaluated. Ninety patients with suspected internal derangements of the knee joint prospectively underwent MR imaging at 1.5 T. For signal detection, a 6-channel array coil was used. All patients were investigated with a standard imaging protocol consisting of different turbo spin-echo sequences proton density (PD), T2-weighted turbo spin echo (TSE) with and without fat suppression) in three imaging planes. All sequences were repeated with an integrated parallel acquisition technique (iPAT) using the modified sensitivity encoding (mSENSE) algorithm with an acceleration factor of 2. Two radiologists independently evaluated and scored all images with regard to overall image quality, artefacts and pathologic findings. Agreement of the parallel ratings between readers and imaging techniques, respectively, was evaluated by means of pairwise kappa coefficients that were stratified for the area of evaluation. Agreement between the parallel readers for both the iPAT imaging and the conventional technique, respectively, as well as between imaging techniques was found encouraging with inter-observer kappa values ranging between 0.78 and 0.98 for both imaging techniques, and the inter-method kappa values ranging between 0.88 and 1.00 for both clinical readers. All pathological findings (e.g. occult fractures, meniscal and cruciate ligament tears, torn and interpositioned Hoffa's cleft, cartilage damage) were detected by both techniques with comparable performance. The use of iPAT lead to a 48% reduction of acquisition time compared with standard technique. Parallel imaging using mSENSE proved to be an efficient and economic tool for fast musculoskeletal MR imaging of the knee joint with comparable diagnostic performance to conventional MR imaging.

Entities:  

Mesh:

Year:  2006        PMID: 16733683     DOI: 10.1007/s00330-006-0288-0

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  29 in total

Review 1.  The meniscus: recent advances in MR imaging of the knee.

Authors:  Clyde A Helms
Journal:  AJR Am J Roentgenol       Date:  2002-11       Impact factor: 3.959

2.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

3.  A four-element phased array coil for high resolution and parallel MR imaging of the knee.

Authors:  Wingchi E Kwok; Jianhui Zhong; Zhigang You; Gwysuk Seo; Saara M S Totterman
Journal:  Magn Reson Imaging       Date:  2003-11       Impact factor: 2.546

4.  Transmit SENSE.

Authors:  Ulrich Katscher; Peter Börnert; Christoph Leussler; Johan S van den Brink
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

5.  [Contrast-enhanced 3D MR angiography of the pulmonary arteries with integrated parallel acquisition technique (iPAT) in patients with chronic-thromboembolic pulmonary hypertension CTEPH - sagittal or coronal acquisition?].

Authors:  K Oberholzer; B Romaneehsen; P Kunz; T Kramm; M Thelen; K-F Kreitner
Journal:  Rofo       Date:  2004-04

6.  Influence of high magnetic field strengths and parallel acquisition strategies on image quality in cardiac 2D CINE magnetic resonance imaging: comparison of 1.5 T vs. 3.0 T.

Authors:  Matthias Gutberlet; Kerstin Schwinge; Patrick Freyhardt; Birgit Spors; Matthias Grothoff; Timm Denecke; Lutz Lüdemann; Ralph Noeske; Thoralf Niendorf; Roland Felix
Journal:  Eur Radiol       Date:  2005-05-05       Impact factor: 5.315

7.  Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays.

Authors:  D K Sodickson; W J Manning
Journal:  Magn Reson Med       Date:  1997-10       Impact factor: 4.668

8.  Usefulness of turbo spin-echo MR imaging in the evaluation of meniscal tears: comparison with a conventional spin-echo sequence.

Authors:  E M Escobedo; J C Hunter; G C Zink-Brody; A J Wilson; S D Harrison; D J Fisher
Journal:  AJR Am J Roentgenol       Date:  1996-11       Impact factor: 3.959

9.  Usefulness of the simultaneous acquisition of spatial harmonics technique during MRI of the shoulder.

Authors:  Thomas Magee; Marc Shapiro; David Williams; R Richard Ramnath; Jeffrey Simon
Journal:  AJR Am J Roentgenol       Date:  2003-10       Impact factor: 3.959

10.  [VIBE with parallel acquisition technique - a novel approach to dynamic contrast-enhanced MR imaging of the liver].

Authors:  M Dobritz; T Radkow; M Nittka; W Bautz; F A Fellner
Journal:  Rofo       Date:  2002-06
View more
  8 in total

1.  Evaluation of image quality of a 32-channel versus a 12-channel head coil at 1.5T for MR imaging of the brain.

Authors:  P T Parikh; G S Sandhu; K A Blackham; M D Coffey; D Hsu; K Liu; J Jesberger; M Griswold; J L Sunshine
Journal:  AJNR Am J Neuroradiol       Date:  2010-12-16       Impact factor: 3.825

2.  The use of parallel imaging for MRI assessment of knees in children and adolescents.

Authors:  Andrea S Doria; Gulraiz A Chaudry; Cristina Nasui; Tammy Rayner; Chenghua Wang; Rahim Moineddin; Paul S Babyn; Larry M White; Marshall S Sussman
Journal:  Pediatr Radiol       Date:  2009-12-01

3.  Parallel reconstruction using null operations.

Authors:  Jian Zhang; Chunlei Liu; Michael E Moseley
Journal:  Magn Reson Med       Date:  2011-05-20       Impact factor: 4.668

4.  Comparison of a fast 5-min knee MRI protocol with a standard knee MRI protocol: a multi-institutional multi-reader study.

Authors:  Erin FitzGerald Alaia; Alex Benedick; Nancy A Obuchowski; Joshua M Polster; Luis S Beltran; Jean Schils; Elisabeth Garwood; Christopher J Burke; I-Yuan Joseph Chang; Soterios Gyftopoulos; Naveen Subhas
Journal:  Skeletal Radiol       Date:  2017-09-26       Impact factor: 2.199

Review 5.  Mechanisms of osteoarthritis in the knee: MR imaging appearance.

Authors:  Lauren M Shapiro; Emily J McWalter; Min-Sun Son; Marc Levenston; Brian A Hargreaves; Garry E Gold
Journal:  J Magn Reson Imaging       Date:  2014-02-19       Impact factor: 4.813

Review 6.  Application of advanced magnetic resonance imaging techniques in evaluation of the lower extremity.

Authors:  Hillary J Braun; Jason L Dragoo; Brian A Hargreaves; Marc E Levenston; Garry E Gold
Journal:  Radiol Clin North Am       Date:  2013-03-09       Impact factor: 2.303

Review 7.  Diagnosis of osteoarthritis: imaging.

Authors:  Hillary J Braun; Garry E Gold
Journal:  Bone       Date:  2011-12-03       Impact factor: 4.398

8.  Feasibility of an accelerated 2D-multi-contrast knee MRI protocol using deep-learning image reconstruction: a prospective intraindividual comparison with a standard MRI protocol.

Authors:  Judith Herrmann; Gabriel Keller; Sebastian Gassenmaier; Dominik Nickel; Gregor Koerzdoerfer; Mahmoud Mostapha; Haidara Almansour; Saif Afat; Ahmed E Othman
Journal:  Eur Radiol       Date:  2022-04-07       Impact factor: 7.034

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.