Literature DB >> 10756992

Age- and gender-specific differences in left and right ventricular cardiac function and mass determined by cine magnetic resonance imaging.

J Sandstede1, C Lipke, M Beer, S Hofmann, T Pabst, W Kenn, S Neubauer, D Hahn.   

Abstract

We examined possible age- and gender-specific differences in the function and mass of left (LV) and right (RV) ventricles in 36 healthy volunteers using cine gradient-recalled echo magnetic resonance imaging. Subjects were divided into four groups (nine men and nine women in each): men aged under 45 years (32 +/- 7), women aged under 45 (27 +/- 6), men aged over 45 (59 +/- 8), and women aged over 45 (57 +/- 9). Functional analysis of cardiac volume and mass and of LV wall motion was performed by manual segmentation of the endocardial and epicardial borders of the end-diastolic and end-systolic frame; both absolute and normalized (per square meter body surface area) values were evaluated. With age there was a significant decrease in both absolute and normalized LV and RV chamber volumes (EDV, ESV), while LV and RV masses remained unchanged. Gender-specific differences were found in cardiac mass and volume (for men and women, respectively: LV mass, 155 +/- 18 and 110 +/- 16 g; LV EDV, 118 +/- 27 and 96 +/- 21 ml; LV ESV, 40 +/- 13 and 29 +/- 9 ml; RV mass, 52 +/- 10 and 39 +/- 5 g; RV EDV, 131 +/- 28 and 100 +/- 23 ml; RV ESV, 53 +/- 17 and 33 +/- 15 ml). Normalization to body surface area eliminated differences in LV volumes but not those in LV mass, RV mass, or RV function. Functional parameters such as cardiac output and LV ejection fraction showed nonsignificant or only slight differences and were thus largely independent of age and gender. Intra- and interobserver variability ranged between 1.4% and 5.9% for all parameters. Cine magnetic resonance imaging thus shows age- and gender-specific differences in cardiac function, and therefore the evaluation of cardiac function in patients should consider age- and gender-matched normative values.

Entities:  

Mesh:

Year:  2000        PMID: 10756992     DOI: 10.1007/s003300050072

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  69 in total

1.  Model dependence of gated blood pool SPECT ventricular function measurements.

Authors:  Kenneth Nichols; Naeem Humayun; Pieter De Bondt; Stijn Vandenberghe; Olakunle O Akinboboye; Steven R Bergmann
Journal:  J Nucl Cardiol       Date:  2004 May-Jun       Impact factor: 5.952

2.  Cardiac index after acute ST-segment elevation myocardial infarction measured with phase-contrast cardiac magnetic resonance imaging.

Authors:  Gert Klug; Sebastian Johannes Reinstadler; Hans-Josef Feistritzer; Christian Kremser; Johannes P Schwaiger; Martin Reindl; Johannes Mair; Silvana Müller; Agnes Mayr; Wolfgang-Michael Franz; Bernhard Metzler
Journal:  Eur Radiol       Date:  2015-09-18       Impact factor: 5.315

3.  Influence of high magnetic field strengths and parallel acquisition strategies on image quality in cardiac 2D CINE magnetic resonance imaging: comparison of 1.5 T vs. 3.0 T.

Authors:  Matthias Gutberlet; Kerstin Schwinge; Patrick Freyhardt; Birgit Spors; Matthias Grothoff; Timm Denecke; Lutz Lüdemann; Ralph Noeske; Thoralf Niendorf; Roland Felix
Journal:  Eur Radiol       Date:  2005-05-05       Impact factor: 5.315

4.  Left ventricular function studied with MDCT.

Authors:  Kai Uwe Juergens; Roman Fischbach
Journal:  Eur Radiol       Date:  2005-08-20       Impact factor: 5.315

5.  Exercise stress echocardiography of the pulmonary circulation: limits of normal and sex differences.

Authors:  Paola Argiento; Rebecca R Vanderpool; Massimiliano Mulè; Maria Giovanna Russo; Michele D'Alto; Eduardo Bossone; Naomi C Chesler; Robert Naeije
Journal:  Chest       Date:  2012-11       Impact factor: 9.410

6.  Assessment of functional anatomy of the mitral valve in patients with mitral regurgitation with cine magnetic resonance imaging: comparison with transesophageal echocardiography and surgical results.

Authors:  A Stork; O Franzen; H Ruschewski; C Detter; K Müllerleile; P M Bansmann; G Adam; G K Lund
Journal:  Eur Radiol       Date:  2007-06-05       Impact factor: 5.315

7.  Assessment of global left ventricular functional parameters: analysis of every second short-axis Magnetic Resonance Imaging slices is as accurate as analysis of consecutive slices.

Authors:  Daniel D Lubbers; Tineke P Willems; Pieter A van der Vleuten; Jelle Overbosch; Marco J W Götte; Dirk J van Veldhuisen; Matthijs Oudkerk
Journal:  Int J Cardiovasc Imaging       Date:  2007-06-28       Impact factor: 2.357

8.  Evaluation of coronary artery disease and cardiac morphology and function in patients with hypertrophic cardiomyopathy, using cardiac computed tomography.

Authors:  Satoshi Okayama; Tsunenari Soeda; Rika Kawakami; Yasuhiro Takami; Satoshi Somekawa; Tomoya Ueda; Yu Sugawara; Takaki Matsumoto; Ji Hee Sung; Taku Nishida; Shiro Uemura; Yoshihiko Saito
Journal:  Heart Vessels       Date:  2013-12-11       Impact factor: 2.037

9.  Long-term cardiovascular outcome following fetal anaemia and intrauterine transfusion: a cohort study.

Authors:  Alexandra H Wallace; Stuart R Dalziel; Brett R Cowan; Alistair A Young; Kent L Thornburg; Jane E Harding
Journal:  Arch Dis Child       Date:  2016-09-23       Impact factor: 3.791

10.  Impact of age, sex, and indexation method on MR left ventricular reference values in the Framingham Heart Study offspring cohort.

Authors:  Susan B Yeon; Carol J Salton; Philimon Gona; Michael L Chuang; Susan J Blease; Yuchi Han; Connie W Tsao; Peter G Danias; Daniel Levy; Christopher J O'Donnell; Warren J Manning
Journal:  J Magn Reson Imaging       Date:  2014-05-12       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.