Hip-spine relationship: a radio-anatomical study for optimization in acetabular cup positioning.

J-Y Lazennec1, N Charlot, M Gorin, B Roger, N Arafati, A Bissery, G Saillant.   

Abstract

The criteria for acetabular cup positioning during total hip replacement are a matter of considerable discussion, particularly with regards to the optimal degree of anteversion. "Anatomical anteversion" is defined in the transverse plane, and "surgical anteversion" in the sagittal plane. Computed tomography measurements of anteversion are characteristic of a given transverse section plane and fail to take into account the position of the pelvis. We suggest a simple method for evaluating acetabular cup position in both the transverse and sagittal planes during standing and sitting. By shedding new light on the relationships between the pelvis and the spine, this method may help to understand some cases of impingement, instability or abnormal wear.

Mesh:

Year:  2003        PMID: 14605752     DOI: 10.1007/s00276-003-0195-x

Source DB:  PubMed          Journal:  Surg Radiol Anat        ISSN: 0930-1038            Impact factor:   1.246


  22 in total

1.  The effect of acetabular cup orientations on limiting hip rotation.

Authors:  F J Kummer; S Shah; S Iyer; P E DiCesare
Journal:  J Arthroplasty       Date:  1999-06       Impact factor: 4.757

2.  Radiographic calculation of anteversion in acetabular prostheses.

Authors:  D M Hassan; G H Johnston; W N Dust; L G Watson; D Cassidy
Journal:  J Arthroplasty       Date:  1995-06       Impact factor: 4.757

3.  Dislocations and the femoral head size in primary total hip arthroplasty.

Authors:  U Hedlundh; L Ahnfelt; C H Hybbinette; L Wallinder; J Weckström; H Fredin
Journal:  Clin Orthop Relat Res       Date:  1996-12       Impact factor: 4.176

4.  Space orientation of total hip prosthesis. A method for three-dimensional determination.

Authors:  K Herrlin; G Selvik; H Pettersson
Journal:  Acta Radiol Diagn (Stockh)       Date:  1986 Nov-Dec

5.  Position, orientation and component interaction in dislocation of the total hip prosthesis.

Authors:  K Herrlin; G Selvik; H Pettersson; P Kesek; R Onnerfält; A Ohlin
Journal:  Acta Radiol       Date:  1988 Jul-Aug       Impact factor: 1.990

6.  Statistical methodology for the concurrent assessment of interrater and intrarater reliability: using goniometric measurements as an example.

Authors:  M Eliasziw; S L Young; M G Woodbury; K Fryday-Field
Journal:  Phys Ther       Date:  1994-08

7.  Dislocations after total hip-replacement arthroplasties.

Authors:  G E Lewinnek; J L Lewis; R Tarr; C L Compere; J R Zimmerman
Journal:  J Bone Joint Surg Am       Date:  1978-03       Impact factor: 5.284

8.  The Frank Stinchfield Award: Morphologic features of the acetabulum and femur: anteversion angle and implant positioning.

Authors:  M Maruyama; J R Feinberg; W N Capello; J A D'Antonio
Journal:  Clin Orthop Relat Res       Date:  2001-12       Impact factor: 4.176

9.  Wear debris from bipolar femoral neck-cup impingement. A cause of femoral stem loosening.

Authors:  M Messieh; D A Mattingly; R H Turner; R Scott; J Fox; J Slater
Journal:  J Arthroplasty       Date:  1994-02       Impact factor: 4.757

10.  Analysis of optimal range of socket orientations in total hip arthroplasty with use of computer-aided design simulation.

Authors:  M Seki; N Yuasa; K Ohkuni
Journal:  J Orthop Res       Date:  1998-07       Impact factor: 3.494

View more
  56 in total

1.  Variations of caudal, central, and cranial acetabular anteversion according to the tilt of the pelvis.

Authors:  S Zilber; J Y Lazennec; M Gorin; G Saillant
Journal:  Surg Radiol Anat       Date:  2004-12       Impact factor: 1.246

2.  Study of the three-dimensional orientation of the labrum: its relations with the osseous acetabular rim.

Authors:  Noémie Bonneau; July Bouhallier; Michel Baylac; Christine Tardieu; Olivier Gagey
Journal:  J Anat       Date:  2012-02-23       Impact factor: 2.610

3.  Pelvic tilt compensates for increased acetabular anteversion.

Authors:  Robert K Zahn; Sarah Grotjohann; Heiko Ramm; Stefan Zachow; Michael Putzier; Carsten Perka; Stephan Tohtz
Journal:  Int Orthop       Date:  2015-08-30       Impact factor: 3.075

4.  Can an Augmented Reality Headset Improve Accuracy of Acetabular Cup Orientation in Simulated THA? A Randomized Trial.

Authors:  Kartik Logishetty; Luke Western; Ruairidh Morgan; Farhad Iranpour; Justin P Cobb; Edouard Auvinet
Journal:  Clin Orthop Relat Res       Date:  2019-05       Impact factor: 4.176

5.  Assessment of cup position from plain radiographs: impact of pelvic tilting.

Authors:  M Haenle; A Heitner; W Mittelmeier; R Barbano; R Scholz; E Steinhauser; R Bader
Journal:  Surg Radiol Anat       Date:  2007-01-10       Impact factor: 1.246

6.  Multilevel measurement of acetabular version using 3-D CT-generated models: implications for hip preservation surgery.

Authors:  Aimee C Perreira; John C Hunter; Thaddeus Laird; Amir A Jamali
Journal:  Clin Orthop Relat Res       Date:  2010-09-25       Impact factor: 4.176

7.  Validation of a simple radiographic method to determine variations in pelvic and acetabular cup sagittal plane alignment after total hip arthroplasty.

Authors:  Won Yong Shon; Siddhartha Gupta; Sandeep Biswal; Chang Yong Hur; Nirmal Jajodia; Suk Joo Hong; Jae Sung Myung
Journal:  Skeletal Radiol       Date:  2008-08-07       Impact factor: 2.199

8.  Toward a dynamic approach of THA planning based on ultrasound.

Authors:  Guillaume Dardenne; Stéphane Dusseau; Chafiaâ Hamitouche; Christian Lefèvre; Eric Stindel
Journal:  Clin Orthop Relat Res       Date:  2008-08-08       Impact factor: 4.176

9.  Influence of the sagittal balance of the spine on the anterior pelvic plane and on the acetabular orientation.

Authors:  Jean Legaye
Journal:  Int Orthop       Date:  2009-01-16       Impact factor: 3.075

10.  An evaluation of CT-scan to locate the femoral head centre and its implication for hip surgeons.

Authors:  Anthony Viste; Franck Trouillet; Rodolphe Testa; Laurence Chèze; Romain Desmarchelier; Michel-Henri Fessy
Journal:  Surg Radiol Anat       Date:  2013-07-24       Impact factor: 1.246

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.