Literature DB >> 7673917

Radiographic calculation of anteversion in acetabular prostheses.

D M Hassan1, G H Johnston, W N Dust, L G Watson, D Cassidy.   

Abstract

The position of the acetabular prosthesis is critical for preventing dislocation following total hip arthroplasty. The reliability of a mathematical model for radiographically calculated acetabular cup version was examined. A porous-coated anatomic acetabular prosthesis was mounted in a mold. Anteroposterior radiographs were taken with the cup in five different positions of anteversion. These were reviewed by five orthopaedic surgeons, and measurements were taken from each radiograph. From these measurements, the mathematically derived degree of version was calculated. The results were examined for accuracy and intraobserver reliability. It was concluded that intraobserver reliability was very good and that the accuracy was within a clinically acceptable range. This technique could be useful in studying the "safe zone" for acetabular prostheses.

Entities:  

Mesh:

Year:  1995        PMID: 7673917     DOI: 10.1016/s0883-5403(05)80187-1

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  33 in total

1.  Hip-spine relationship: a radio-anatomical study for optimization in acetabular cup positioning.

Authors:  J-Y Lazennec; N Charlot; M Gorin; B Roger; N Arafati; A Bissery; G Saillant
Journal:  Surg Radiol Anat       Date:  2003-11-07       Impact factor: 1.246

2.  Measuring acetabular component version after THA: CT or plain radiograph?

Authors:  Benjamin McArthur; Michael Cross; Christina Geatrakas; David Mayman; Bernard Ghelman
Journal:  Clin Orthop Relat Res       Date:  2012-03-01       Impact factor: 4.176

3.  Accuracy and reliability of different methods to evaluate the acetabular cup version from plain radiographs.

Authors:  Maximilian Haenle; Wolfram Mittelmeier; Rodrigo Barbano; Klaus Wörtler; Roger Scholz; Rainer Bader
Journal:  Surg Radiol Anat       Date:  2010-06-25       Impact factor: 1.246

4.  Anteroposterior Radiographs Are More Accurate than Cross-Table Lateral Radiographs for Acetabular Anteversion Assessment: a Retrospective Cohort Study.

Authors:  Peter K Sculco; Alexander S McLawhorn; Kaitlin M Carroll; Benjamin A McArthur; David J Mayman
Journal:  HSS J       Date:  2015-10-19

5.  Assessment of cup position from plain radiographs: impact of pelvic tilting.

Authors:  M Haenle; A Heitner; W Mittelmeier; R Barbano; R Scholz; E Steinhauser; R Bader
Journal:  Surg Radiol Anat       Date:  2007-01-10       Impact factor: 1.246

Review 6.  Enhanced acetabular component positioning through computer-assisted navigation.

Authors:  Thomas Ybinger; Wolfgang Kumpan
Journal:  Int Orthop       Date:  2007-08       Impact factor: 3.075

Review 7.  Imaging and navigation measurement of acetabular component position in THA.

Authors:  Zhinian Wan; Aamer Malik; Branislav Jaramaz; Lisa Chao; Lawrence D Dorr
Journal:  Clin Orthop Relat Res       Date:  2008-11-01       Impact factor: 4.176

8.  Comments on Reito et al.: Assessment of inter- and intra-observer reliability in the determination of radiographic version and inclination of the cup in metal-on-metal hip resurfacing.

Authors:  Vikas Bachhal; Sushil Rangdal; Gaurav Saini; Mandeep Dhillon
Journal:  Int Orthop       Date:  2012-05-15       Impact factor: 3.075

9.  Estimation of pelvic tilt on anteroposterior X-rays--a comparison of six parameters.

Authors:  M Tannast; S B Murphy; F Langlotz; S E Anderson; K A Siebenrock
Journal:  Skeletal Radiol       Date:  2005-12-20       Impact factor: 2.199

Review 10.  [Navigation in hip joint revision endoprosthetics].

Authors:  P A Grützner
Journal:  Orthopade       Date:  2009-08       Impact factor: 1.087

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.