Literature DB >> 18688691

Toward a dynamic approach of THA planning based on ultrasound.

Guillaume Dardenne1, Stéphane Dusseau, Chafiaâ Hamitouche, Christian Lefèvre, Eric Stindel.   

Abstract

The risk of dislocation after THA reportedly is minimized if the acetabular implant is oriented at 45 degrees inclination and 15 degrees anteversion with respect to the anterior pelvic plane. This reference plane now is used in computer-assisted protocols. However, this static approach may lead to postoperative instability because the dynamic variations of the pelvis influence effective cup orientation and are not taken into account in this approach. We propose an ultrasound tool to register the preoperative dynamics of the pelvis for THA planning during computer-assisted surgery. To assess this pelvic behavior and its consequences on implant orientation, we tested a new 2.5-dimensional ultrasound-based approach. The pelvic flexion was registered in sitting, standing, and supine positions in 20 subjects. The mean values were -25.2 degrees +/- 5.8 degrees (standard deviation), 2.4 degrees +/- 5.1 degrees , and 6.8 degrees +/- 3.5 degrees , respectively. The mean functional anteversion varied by 26 degrees and the mean functional inclination by 12 degrees depending on the pelvic flexion. We therefore recommend including dynamic pelvic behavior to minimize dislocation risk. The notion of a safe zone should be revisited and extended to include changes with activity.

Entities:  

Mesh:

Year:  2008        PMID: 18688691      PMCID: PMC2650058          DOI: 10.1007/s11999-008-0408-z

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  17 in total

1.  Hip-spine relationship: a radio-anatomical study for optimization in acetabular cup positioning.

Authors:  J-Y Lazennec; N Charlot; M Gorin; B Roger; N Arafati; A Bissery; G Saillant
Journal:  Surg Radiol Anat       Date:  2003-11-07       Impact factor: 1.246

2.  A new optimization approach for the calibration of an ultrasound probe using a 3D optical localizer.

Authors:  G Dardenne; J D Gil Cano; C Hamitouche; E Stindel; C Roux
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2007

3.  Pelvic incidence: a fundamental pelvic parameter for three-dimensional regulation of spinal sagittal curves.

Authors:  J Legaye; G Duval-Beaupère; J Hecquet; C Marty
Journal:  Eur Spine J       Date:  1998       Impact factor: 3.134

4.  Rapid calibration for 3-D freehand ultrasound.

Authors:  R W Prager; R N Rohling; A H Gee; L Berman
Journal:  Ultrasound Med Biol       Date:  1998-07       Impact factor: 2.998

5.  Variations of pelvic anteversion in the lying and standing positions: analysis of 24 control subjects and implications for CT measurement of position of a prosthetic cup.

Authors:  T A Eddine; H Migaud; C Chantelot; A Cotten; C Fontaine; A Duquennoy
Journal:  Surg Radiol Anat       Date:  2001       Impact factor: 1.246

6.  The definition and measurement of acetabular orientation.

Authors:  D W Murray
Journal:  J Bone Joint Surg Br       Date:  1993-03

7.  Dislocations after total hip-replacement arthroplasties.

Authors:  G E Lewinnek; J L Lewis; R Tarr; C L Compere; J R Zimmerman
Journal:  J Bone Joint Surg Am       Date:  1978-03       Impact factor: 5.284

8.  Dislocation after total hip arthroplasty. Causes and prevention.

Authors:  D E McCollum; W J Gray
Journal:  Clin Orthop Relat Res       Date:  1990-12       Impact factor: 4.176

9.  Measurements of pelvic flexion angle using three-dimensional computed tomography.

Authors:  Shunsaku Nishihara; Nobuhiko Sugano; Takashi Nishii; Kenji Ohzono; Hideki Yoshikawa
Journal:  Clin Orthop Relat Res       Date:  2003-06       Impact factor: 4.176

10.  Computer assisted measurement of cup placement in total hip replacement.

Authors:  B Jaramaz; A M DiGioia; M Blackwell; C Nikou
Journal:  Clin Orthop Relat Res       Date:  1998-09       Impact factor: 4.176

View more
  3 in total

1.  Multilevel measurement of acetabular version using 3-D CT-generated models: implications for hip preservation surgery.

Authors:  Aimee C Perreira; John C Hunter; Thaddeus Laird; Amir A Jamali
Journal:  Clin Orthop Relat Res       Date:  2010-09-25       Impact factor: 4.176

2.  Lewinnek Safe Zone References are Frequently Misquoted.

Authors:  Aonnicha Burapachaisri; Ameer Elbuluk; Edem Abotsi; Jim Pierrepont; Seth A Jerabek; Aaron J Buckland; Jonathan M Vigdorchik
Journal:  Arthroplast Today       Date:  2020-11-26

3.  Does Acetabular Coverage Vary Between the Supine and Standing Positions in Patients with Hip Dysplasia?

Authors:  Tetsuya Tachibana; Masanori Fujii; Kenji Kitamura; Tetsuro Nakamura; Yasuharu Nakashima
Journal:  Clin Orthop Relat Res       Date:  2019-11       Impact factor: 4.176

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.