| Literature DB >> 8981900 |
U Hedlundh1, L Ahnfelt, C H Hybbinette, L Wallinder, J Weckström, H Fredin.
Abstract
The dislocation rate of 3197 Charnley prostheses with 22 mm head in which the surgery was done between 1979 and 1991 in 2 orthopaedic centers was compared with that of 2875 Lubinus prostheses with 32 mm head in which the surgery was done between 1980 to 1991 in 3 other centers. A 1-year followup showed an equal rate of dislocation (2.4%-2.5%) in the 2 groups and included 75% of the 201 dislocated hips. Almost all of the late dislocations occurred with the Charnley prosthesis, resulting in a total dislocation rate of 3.7% compared with 2.9% with the Lubinus prosthesis. Regardless of the type of prosthesis used, there was a higher risk of dislocation in patients with nonhealed hip fractures and in arthroplasties performed by less experienced surgeons. When these 2 variables were removed, the small femoral head was not associated with an increased risk of dislocation. However, there were 77 of 118 (65%) recurrent dislocations in the Charnley group, compared with 37 of 83 (45%) in the Lubinus group, and the relative risk of a dislocated hip arthroplasty becoming recurrent increased by 2.3 times if the small femoral head was used. The number of reoperations also were doubled in this group. Almost 4 times as many dislocations were documented within 2 weeks after surgery after any type of prosthesis inserted through a posterior approach compared with the transtrochanteric approach, but there was no increase in rate of recurrence or revision.Entities:
Mesh:
Year: 1996 PMID: 8981900
Source DB: PubMed Journal: Clin Orthop Relat Res ISSN: 0009-921X Impact factor: 4.176