OBJECTIVE: To compare observer performance using liquid-crystal display (LCD) and cathode-ray tube (CRT) monitors in the interpretation of soft-copy chest radiographs for the detection of small solitary pulmonary nodules. MATERIALS AND METHODS: By reviewing our Medical Center's radiologic information system, the eight radiologists participating in this study (three board-certified and five resident) retrospectively collected 40 chest radiographs showing a solitary noncalcified pulmonary nodule approximately 1 cm in diameter, and 40 normal chest radiographs. All were obtained using a storage-phosphor system, and CT scans of the same patients served as the gold standard for the presence of a pulmonary nodule. Digital images were displayed on both high-resolution LCD and CRT monitors. The readers were requested to rank each image using a fivepoint scale (1 = definitely negative, 3 = equivocal or indeterminate, 5 = definitely positive), and the data were interpreted using receiver operating characteristic (ROC) analysis. RESULTS: The mean area under the ROC curve was 0.8901+/- 0.0259 for the LCD session, and 0.8716+/- 0.0266 for the CRT session (p > 0.05). The reading time for the LCD session was not significantly different from that for the CRT session (37.12 and 41.46 minutes, respectively; p = 0.889). CONCLUSION: For detecting small solitary pulmonary nodules, an LCD monitor and a CRT monitor are comparable.
OBJECTIVE: To compare observer performance using liquid-crystal display (LCD) and cathode-ray tube (CRT) monitors in the interpretation of soft-copy chest radiographs for the detection of small solitary pulmonary nodules. MATERIALS AND METHODS: By reviewing our Medical Center's radiologic information system, the eight radiologists participating in this study (three board-certified and five resident) retrospectively collected 40 chest radiographs showing a solitary noncalcified pulmonary nodule approximately 1 cm in diameter, and 40 normal chest radiographs. All were obtained using a storage-phosphor system, and CT scans of the same patients served as the gold standard for the presence of a pulmonary nodule. Digital images were displayed on both high-resolution LCD and CRT monitors. The readers were requested to rank each image using a fivepoint scale (1 = definitely negative, 3 = equivocal or indeterminate, 5 = definitely positive), and the data were interpreted using receiver operating characteristic (ROC) analysis. RESULTS: The mean area under the ROC curve was 0.8901+/- 0.0259 for the LCD session, and 0.8716+/- 0.0266 for the CRT session (p > 0.05). The reading time for the LCD session was not significantly different from that for the CRT session (37.12 and 41.46 minutes, respectively; p = 0.889). CONCLUSION: For detecting small solitary pulmonary nodules, an LCD monitor and a CRT monitor are comparable.
Authors: M S Frank; R G Jost; P L Molina; D J Anderson; S L Solomon; R A Whitman; S M Moore Journal: AJR Am J Roentgenol Date: 1993-03 Impact factor: 3.959
Authors: E A Krupinski; K Maloney; S C Bessen; M P Capp; K Graham; R Hunt; P Lund; T Ovitt; J R Standen Journal: Invest Radiol Date: 1994-02 Impact factor: 6.016
Authors: F L Thaete; C R Fuhrman; J H Oliver; C A Britton; W L Campbell; J H Feist; W H Straub; P L Davis; M B Plunkett Journal: AJR Am J Roentgenol Date: 1994-03 Impact factor: 3.959