Literature DB >> 981610

Observer performance in detecting multiple radiographic signals. Prediction and analysis using a generalized ROC approach.

C E Metz, S J Starr, L B Lusted.   

Abstract

The theories of decision processes and signal detection provide a framework for evaluation of observer performance. Some radiological procedures involve a search for multiple similar lesions, e.g., plain radiographic examinations for gallstones or pneumoconiosis. Presuming knowledge of the conventional ROC curve for detection of a single radiographic signal, a model is presented which is used to predict observer performance in an experiment requiring detection of more than one such signal. An experiment tests the validity of this model for detecting radiographically the presence of zero, one, or two low-contrast, 2-mm diameter, Lucite beads. Results confirm the validity of the model and suggest that observer performance in relatively complex detection tasks can be predicted from simpler experiments.

Entities:  

Mesh:

Year:  1976        PMID: 981610     DOI: 10.1148/121.2.337

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  4 in total

1.  Effect of greyscale liquid crystal displays of different resolutions on observer performance during detection of small solitary pulmonary nodules.

Authors:  J Yin; Q Guo; W Zhang; H Su; J Zhang; Y Yue; C Ding; A Lin; Y Wang; H Wang
Journal:  Br J Radiol       Date:  2012-06-27       Impact factor: 3.039

2.  Observer study for evaluating potential utility of a super-high-resolution LCD in the detection of clustered microcalcifications on digital mammograms.

Authors:  Junji Shiraishi; Hiroyuki Abe; Katsuhiro Ichikawa; Robert A Schmidt; Kunio Doi
Journal:  J Digit Imaging       Date:  2009-03-10       Impact factor: 4.056

3.  Quantitative imaging to assess tumor response to therapy: common themes of measurement, truth data, and error sources.

Authors:  Charles R Meyer; Samuel G Armato; Charles P Fenimore; Geoffrey McLennan; Luc M Bidaut; Daniel P Barboriak; Marios A Gavrielides; Edward F Jackson; Michael F McNitt-Gray; Paul E Kinahan; Nicholas Petrick; Binsheng Zhao
Journal:  Transl Oncol       Date:  2009-12       Impact factor: 4.243

4.  Liquid-crystal display monitors and cathode-ray tube monitors: a comparison of observer performance in the detection of small solitary pulmonary nodules.

Authors:  Soon-A Hwang; Joon Beom Seo; Byeong-Kyoo Choi; Kyung-Hyun Do; Sung Min Ko; Soo-Hyun Lee; Jin-Seong Lee; Jae-Woo Song; Koun-Sik Song; Tae-Hwan Lim
Journal:  Korean J Radiol       Date:  2003 Jul-Sep       Impact factor: 3.500

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.