Literature DB >> 22744323

Effect of greyscale liquid crystal displays of different resolutions on observer performance during detection of small solitary pulmonary nodules.

J Yin1, Q Guo, W Zhang, H Su, J Zhang, Y Yue, C Ding, A Lin, Y Wang, H Wang.   

Abstract

OBJECTIVE: The aim of this study was to evaluate the effect of monochrome liquid crystal displays (LCDs) with different resolutions on observer performance during detection of small solitary pulmonary nodules.
METHODS: Chest images of digital radiography were selected online from the hospital's picture archiving and communication system. Of the 164 images selected, small solitary non-calcified pulmonary nodules were present in 63 images and absent in 101 images. Observer performance was assessed among 3 extremely experienced, 3 very experienced and 3 moderately experienced radiologists, who independently interpreted these images on 2, 3 and 5 megapixel greyscale LCDs. A five-point confidence level rating scale was used to represent the presence of nodules: definite absence, probable absence, indetermination, probable presence and definite presence. The observers were requested to rank each image on the given display according to the presence of the pulmonary nodule. Observer performance was analysed in terms of receiver operating characteristics (ROCs).
RESULTS: The areas under the ROC curves which represented the observer performance for the 2, 3 and 5 megapixel LCDs were found to be 0.705, 0.722 and 0.764, respectively, for the extremely experienced radiologists; 0.687, 0.712 and 0.721, respectively, for the very experienced radiologists; and 0.689, 0.696 and 0.711, respectively, for the moderately experienced radiologists. These differences were not statistically significant.
CONCLUSION: The observer performances for detection of small solitary non-calcified pulmonary nodules by radiologists with varying degrees of experience were comparable between the 2, 3 and 5 megapixel monochrome LCDs.

Mesh:

Year:  2012        PMID: 22744323      PMCID: PMC3487067          DOI: 10.1259/bjr/19867962

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  29 in total

1.  Comparison of liquid crystal versus cathode ray tube display for the detection of simulated chest lesions.

Authors:  Elisabeth Oschatz; Mathias Prokop; Martina Scharitzer; Michael Weber; Csilla Balassy; Cornelia Schaefer-Prokop
Journal:  Eur Radiol       Date:  2004-09-08       Impact factor: 5.315

2.  Detection or decision errors? Missed lung cancer from the posteroanterior chest radiograph.

Authors:  D J Manning; S C Ethell; T Donovan
Journal:  Br J Radiol       Date:  2004-03       Impact factor: 3.039

3.  Flat-panel display (LCD) versus high-resolution gray-scale display (CRT) for chest radiography: an observer preference study.

Authors:  Csilla Balassy; Mathias Prokop; Michael Weber; Johannes Sailer; Christian J Herold; Cornelia Schaefer-Prokop
Journal:  AJR Am J Roentgenol       Date:  2005-03       Impact factor: 3.959

4.  The influence of liquid crystal display (LCD) monitors on observer performance for the detection of nodular lesions on chest radiographs.

Authors:  H Usami; M Ikeda; T Ishigaki; H Fukushima; K Shimamoto
Journal:  Eur Radiol       Date:  2005-11-12       Impact factor: 5.315

5.  ROC study of four LCD displays under typical medical center lighting conditions.

Authors:  Steve Langer; Ken Fetterly; Jay Mandrekar; Scott Harmsen; Brian Bartholmai; Charles Patton; Alan Bishop; Colin McCannel
Journal:  J Digit Imaging       Date:  2006-03       Impact factor: 4.056

6.  [Evaluation of the perceptional performance of high resolution flat panel displays].

Authors:  Yoko Araki; Shigeru Sanada; Takeshi Kobayashi; Noriyuki Hashimoto; Shintaro Funabasama
Journal:  Nihon Hoshasen Gijutsu Gakkai Zasshi       Date:  2005-08-20

7.  Visual scanning patterns of radiologists searching mammograms.

Authors:  E A Krupinski
Journal:  Acad Radiol       Date:  1996-02       Impact factor: 3.173

8.  Observer performance in detecting multiple radiographic signals. Prediction and analysis using a generalized ROC approach.

Authors:  C E Metz; S J Starr; L B Lusted
Journal:  Radiology       Date:  1976-11       Impact factor: 11.105

9.  Detectability of catheters on bedside chest radiographs: comparison between liquid crystal display and high-resolution cathode-ray tube monitors.

Authors:  Martina Scharitzer; Mathias Prokop; Michael Weber; Michael Fuchsjäger; Elisabeth Oschatz; Cornelia Schaefer-Prokop
Journal:  Radiology       Date:  2004-12-15       Impact factor: 11.105

10.  SCAR R&D Symposium 2003: comparing the efficacy of 5-MP CRT versus 3-MP LCD in the evaluation of interstitial lung disease.

Authors:  Steve Langer; Brian Bartholmai; Ken Fetterly; Scott Harmsen; William Ryan; Brad Erickson; Kathy Andriole; John Carrino
Journal:  J Digit Imaging       Date:  2004-06-29       Impact factor: 4.056

View more
  1 in total

1.  Effect of display type and room illuminance in chest radiographs.

Authors:  Esa Liukkonen; Airi Jartti; Marianne Haapea; Heljä Oikarinen; Lauri Ahvenjärvi; Seija Mattila; Terhi Nevala; Kari Palosaari; Marja Perhomaa; Miika T Nieminen
Journal:  Eur Radiol       Date:  2015-12-10       Impact factor: 5.315

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.