Receiver operating characteristic evaluation of computer display of adult portable chest radiographs.

E A Krupinski1, K Maloney, S C Bessen, M P Capp, K Graham, R Hunt, P Lund, T Ovitt, J R Standen.   

Abstract

RATIONALE AND
OBJECTIVES: The suitability of using an image console monitor for interpretation of adult portable chest radiographs was evaluated with receiver operating characteristic (ROC) analysis and subjective techniques.
METHODS: Radiologists read 80 chest images, once on a display monitor and once on computed radiography film, for the presence or absence of pneumothorax or atelectasis. Judgments of correct or incorrect positions of tubes and lines were reported, and total viewing time was recorded.
RESULTS: A statistically significant difference was found in favor of monitor reading for detection of pneumothoraces. Atelectasis detection also was higher with monitor reading, but the difference did not reach statistical significance. Tube/line judgments were equivalent for both modes. Total viewing time was approximately 1 minute longer per image with the monitor.
CONCLUSIONS: Viewing computed radiography images on a workstation monitor does not seem to affect diagnostic accuracy compared with film viewing. Preset image defaults tailored to the individual radiologist could decrease total viewing time to acceptable levels.

Mesh:

Year:  1994        PMID: 8169087     DOI: 10.1097/00004424-199402000-00003

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  3 in total

1.  Investigation of optimal viewing size for detecting nodular ground-glass opacity on high-resolution computed tomography with cine-mode display.

Authors:  Michihiro Yamaguchi; Yuichi Bessho; Tatsuro Inoue; Yoshiyuki Asai; Tomoshige Matsumoto; Kenya Murase
Journal:  Radiol Phys Technol       Date:  2010-08-19

2.  Support line and tube visibility in chest examinations using computed radiography.

Authors:  W Huda; C J Belden; L A Webb; C K Palmer
Journal:  J Digit Imaging       Date:  1997-08       Impact factor: 4.056

3.  Liquid-crystal display monitors and cathode-ray tube monitors: a comparison of observer performance in the detection of small solitary pulmonary nodules.

Authors:  Soon-A Hwang; Joon Beom Seo; Byeong-Kyoo Choi; Kyung-Hyun Do; Sung Min Ko; Soo-Hyun Lee; Jin-Seong Lee; Jae-Woo Song; Koun-Sik Song; Tae-Hwan Lim
Journal:  Korean J Radiol       Date:  2003 Jul-Sep       Impact factor: 3.500

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.