Literature DB >> 8816520

Subtle pulmonary disease: detection with computed radiography versus conventional chest radiography.

T Ishigaki1, T Endo, M Ikeda, M Kono, S Yoshida, J Ikezoe, K Murata, M Matsumoto.   

Abstract

PURPOSE: To determine the diagnostic efficacy of hard- and soft-copy computed radiographic (CR) images versus conventional screen-film images of the chest in the detection of subtle pulmonary abnormalities.
MATERIALS AND METHODS: Twenty observes compared 87 hard-copy and soft-copy CR images with hard-copy screen-film images. Of 87 test images, 45 (including two identical sets of 12 images to test intra-observer variability) were abnormal and 42 (including two identical sets of 12 images) were normal. Of the 45 abnormal images, 15 (including two sets of four identical images) showed subtle abnormalities, 15 (including two sets of four identical images) showed mild abnormalities, and 15 (including two sets of four identical images) showed obvious abnormalities. Soft-copy viewing provided three differently processed images of every radiograph.
RESULTS: No statistically significant differences in receiver operating characteristic analyses were found among hard-copy screen-film images, hard-copy CR images, and soft-copy CR images, even in the group with subtle interstitial abnormalities.
CONCLUSION: Hard-copy and soft-copy chest CR images are acceptable and available in place of screen-film images for primary interpretation of subtle interstitial lung diseases.

Entities:  

Mesh:

Year:  1996        PMID: 8816520     DOI: 10.1148/radiology.201.1.8816520

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  7 in total

1.  The influence of liquid crystal display (LCD) monitors on observer performance for the detection of nodular lesions on chest radiographs.

Authors:  H Usami; M Ikeda; T Ishigaki; H Fukushima; K Shimamoto
Journal:  Eur Radiol       Date:  2005-11-12       Impact factor: 5.315

2.  ROC analysis for diagnostic accuracy of fracture by using different monitors.

Authors:  Zhigang Liang; Kuncheng Li; Xiaolin Yang; Xiangying Du; Jiabin Liu; Xin Zhao; Xiangdong Qi
Journal:  J Digit Imaging       Date:  2006-09       Impact factor: 4.056

3.  Two K versus 4 K storage phosphor chest radiography: detection performance and image quality.

Authors:  Claus Koelblinger; Mathias Prokop; Michael Weber; Johannes Sailer; Fabiola Cartes-Zumelzu; Cornelia Schaefer-Prokop
Journal:  Eur Radiol       Date:  2007-05-10       Impact factor: 5.315

4.  Clinical evaluation of irreversible data compression for computed radiography of the chest.

Authors:  K Egashira; H Nakata; H Watanabe; K Uchida; K Nakamura; Y Ishino; K Horino; R Yoshikawa
Journal:  J Digit Imaging       Date:  1998-11       Impact factor: 4.056

5.  Liquid-crystal display monitors and cathode-ray tube monitors: a comparison of observer performance in the detection of small solitary pulmonary nodules.

Authors:  Soon-A Hwang; Joon Beom Seo; Byeong-Kyoo Choi; Kyung-Hyun Do; Sung Min Ko; Soo-Hyun Lee; Jin-Seong Lee; Jae-Woo Song; Koun-Sik Song; Tae-Hwan Lim
Journal:  Korean J Radiol       Date:  2003 Jul-Sep       Impact factor: 3.500

6.  Effect of LCD monitor type and observer experience on diagnostic performance in soft-copy interpretations of the maxillary sinus on panoramic radiographs.

Authors:  Tae-Young Kim; Jin-Woo Choi; Sam-Sun Lee; Kyung-Hoe Huh; Won-Jin Yi; Min-Suk Heo; Soon-Chul Choi
Journal:  Imaging Sci Dent       Date:  2011-03-26

7.  Influence of liquid crystal display monitors on observer performance for detection of diffuse pulmonary disease on chest radiographs.

Authors:  Hiromichi Fukushima; Mitsuru Ikeda; Takeo Ishigaki; Hisashi Usami; Kazuhiro Shimamoto
Journal:  Radiat Med       Date:  2007-06-27
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.