Efficacy of breast shielding during CT of the head.

Z Brnić1, B Vekić, A Hebrang, P Anić.   

Abstract

In light of increasing frequency of CT examinations in the past decades, the aims of this prospective study were to investigate scatter radiation breast exposure in head CT and its dependence upon body constitution, and to assess the efficacy of lead shielding as a means of breast dose reduction. In 49 women referred to head CT for objective medical reasons one breast was covered with lead apron during CT scanning. Radiation doses were measured by use of thermoluminescent dosimeters, at skin of both breasts and over the apron. The doses were then compared as well as correlated to body mass index and meatus acusticus externus-to-dosimeter distance, respectively. Average exposure at the skin of the unshielded breast was 0.28 mGy (range 0.15-0.41 mGy), compared with 0.13 mGy (range 0.05-0.29 mGy) at the shielded breast. The doses showed a mean reduction by 57% due to lead shielding. At least half of breast exposure was imparted to the breast from outside, whereas the remainder results from internal scatter. The higher the body mass index, the higher the percentage of internal scatter in total breast dose. Although the level of scatter radiation to the breast is generally low during head CT examination, the use of lead cover enables recognizable further reduction of the exposure, and is recommended as a feasible and effective procedure of breast protection during CT of the head.

Entities:  

Mesh:

Year:  2003        PMID: 12827426     DOI: 10.1007/s00330-003-1945-1

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  22 in total

1.  Investigation of thyroid dose due to mammography.

Authors:  C Whelan; D McLean; A Poulos
Journal:  Australas Radiol       Date:  1999-08

2.  Radiation exposure in multi-slice CT of the heart.

Authors:  M Cohnen; L Poll; C Püttmann; K Ewen; U Mödder
Journal:  Rofo       Date:  2001-04

3.  Main dosimetric characteristics of some tissue-equivalent TL detectors.

Authors:  S Miljanić; M Ranogajec-Komor; Z Knezević; B Vekić
Journal:  Radiat Prot Dosimetry       Date:  2002       Impact factor: 0.972

4.  [Dosage measurements in spiral CT examinations of the head and neck region].

Authors:  M Cohnen; B Cohnen; K Ewen; G Teubert; U Mödder
Journal:  Rofo       Date:  1998-05

5.  Radiation exposure in spiral computed tomography. Dose distribution and dose reduction.

Authors:  N Hidajat; J Mäurer; R J Schröder; M Wolf; T Vogl; R Felix
Journal:  Invest Radiol       Date:  1999-01       Impact factor: 6.016

6.  The breast: in-plane x-ray protection during diagnostic thoracic CT--shielding with bismuth radioprotective garments.

Authors:  K D Hopper; S H King; M E Lobell; T R TenHave; J S Weaver
Journal:  Radiology       Date:  1997-12       Impact factor: 11.105

7.  CT scanner dosimetry.

Authors:  P C Shrimpton; S Edyvean
Journal:  Br J Radiol       Date:  1998-01       Impact factor: 3.039

8.  [The efficacy of lead shielding in patient dosage reduction in computed tomography].

Authors:  N Hidajat; R J Schröder; T Vogl; H Schedel; R Felix
Journal:  Rofo       Date:  1996-11

9.  Efficacy and feasibility of breast shielding during abdominal fluoroscopic examinations.

Authors:  L A Fordham; E D Brown; D Washburn; R L Clark
Journal:  Acad Radiol       Date:  1997-09       Impact factor: 3.173

10.  A pilot survey of radiation doses received in the United Kingdom Breast Screening Programme.

Authors:  A Burch; D A Goodman
Journal:  Br J Radiol       Date:  1998-05       Impact factor: 3.039

View more
  10 in total

1.  Organ and effective dose reduction in adult chest CT using abdominal lead shielding.

Authors:  G R Iball; D S Brettle
Journal:  Br J Radiol       Date:  2011-11       Impact factor: 3.039

2.  Quantitative assessment of selective in-plane shielding of tissues in computed tomography through evaluation of absorbed dose and image quality.

Authors:  J Geleijns; M Salvadó Artells; W J H Veldkamp; M López Tortosa; A Calzado Cantera
Journal:  Eur Radiol       Date:  2006-04-08       Impact factor: 5.315

3.  Usefulness of a lead shielding device for reducing the radiation dose to tissues outside the primary beams during CT.

Authors:  Jae-Joon Chung; Eun-Suk Cho; Sung Min Kang; Jeong-Sik Yu; Dae Jung Kim; Joo Hee Kim
Journal:  Radiol Med       Date:  2014-06-06       Impact factor: 3.469

4.  Efficacy of breast shielding during head computed tomography examination.

Authors:  Nika Zalokar; Nejc Mekis
Journal:  Radiol Oncol       Date:  2020-08-01       Impact factor: 2.991

Review 5.  CT dose reduction in children.

Authors:  Peter Vock
Journal:  Eur Radiol       Date:  2005-08-10       Impact factor: 5.315

6.  Adaptive planning using megavoltage fan-beam CT for radiation therapy with testicular shielding.

Authors:  Poonam Yadav; Kevin Kozak; Ranjini Tolakanahalli; V Ramasubramanian; Bhudatt R Paliwal; James S Welsh; Yi Rong
Journal:  Med Dosim       Date:  2011-09-16       Impact factor: 1.482

7.  Effectiveness of Breast and Eye Shielding During Cervical Spine Radiography: An Experimental Study.

Authors:  Wiam Elshami; Mohamed M Abuzaid; H O Tekin
Journal:  Risk Manag Healthc Policy       Date:  2020-06-30

8.  Effects of shielding the radiosensitive superficial organs of ORNL pediatric phantoms on dose reduction in computed tomography.

Authors:  Parisa Akhlaghi; Hashem Miri-Hakimabad; Laleh Rafat-Motavalli
Journal:  J Med Phys       Date:  2014-10

9.  Efficacy of breast shielding during head computed tomography examination.

Authors:  Nika Zalokar; Nejc Mekis
Journal:  Radiol Oncol       Date:  2020-08-01       Impact factor: 2.991

10.  The effect of breast shielding during lumbar spine radiography.

Authors:  Nejc Mekis; Dejan Zontar; Damijan Skrk
Journal:  Radiol Oncol       Date:  2013-02-01       Impact factor: 2.991

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.