A pilot survey of radiation doses received in the United Kingdom Breast Screening Programme.

A Burch1, D A Goodman.   

Abstract

A survey of radiation dose and compressed breast thickness was conducted in samples of women undergoing mammography in the United Kingdom National Health Service breast screening programme. The aims were to determine the average value and distribution of dose and thickness, and to identify technical difficulties in carrying out such a survey. Values of breast thickness and mean glandular dose, calculated from exposure factors and measured X-ray beam parameters, were collected for 4633 women in 92 screening units in 1994 and 1995. The median (lower quartile, upper quartile) dose per film was 1.7 (1.2, 2.4) mGy for the mediolateral oblique view (mean thickness 57 mm) and 1.4 (1.1, 2.0) mGy for the craniocaudal view (mean thickness 52 mm). The median dose per woman was 1.8 (1.3, 2.5) mGy for a one-view examination and 3.3 (2.3, 4.6) mGy for a two-view examination. The dose per film showed an exponential relationship to breast thickness, but no relationship was found between median dose and median breast thickness in the different screening units, possibly because of errors in breast thickness measurement. The values of breast thickness and dose were generally consistent with those in other published surveys, allowing for differences in radiographic technique. No relationship between breast dose and standard optical density was demonstrated. Some recommendations for the conduct of future surveys of breast dose in the UK are proposed.

Entities:  

Mesh:

Year:  1998        PMID: 9691897     DOI: 10.1259/bjr.71.845.9691897

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  4 in total

1.  Efficacy of breast shielding during CT of the head.

Authors:  Z Brnić; B Vekić; A Hebrang; P Anić
Journal:  Eur Radiol       Date:  2003-06-25       Impact factor: 5.315

2.  Patient dose in full-field digital mammography: an Italian survey.

Authors:  Gisella Gennaro; Paola Baldelli; Angelo Taibi; Cosimo Di Maggio; Mauro Gambaccini
Journal:  Eur Radiol       Date:  2003-08-12       Impact factor: 5.315

Review 3.  Reconstruction of absorbed doses to fibroglandular tissue of the breast of women undergoing mammography (1960 to the present).

Authors:  Isabelle Thierry-Chef; Steven L Simon; Robert M Weinstock; Deukwoo Kwon; Martha S Linet
Journal:  Radiat Res       Date:  2011-10-12       Impact factor: 2.841

4.  Dose comparison between screen/film and full-field digital mammography.

Authors:  Gisella Gennaro; Cosimo di Maggio
Journal:  Eur Radiol       Date:  2006-05-30       Impact factor: 7.034