Quantitative assessment of selective in-plane shielding of tissues in computed tomography through evaluation of absorbed dose and image quality.

J Geleijns1, M Salvadó Artells, W J H Veldkamp, M López Tortosa, A Calzado Cantera.   

Abstract

This study aimed at assessment of efficacy of selective in-plane shielding in adults by quantitative evaluation of the achieved dose reduction and image quality. Commercially available accessories for in-plane shielding of the eye lens, thyroid and breast, and an anthropomorphic phantom were used for the evaluation of absorbed dose and image quality. Organ dose and total energy imparted were assessed by means of a Monte Carlo technique taking into account tube voltage, tube current, and scanner type. Image quality was quantified as noise in soft tissue. Application of the lens shield reduced dose to the lens by 27% and to the brain by 1%. The thyroid shield reduced thyroid dose by 26%; the breast shield reduced dose to the breasts by 30% and to the lungs by 15%. Total energy imparted (unshielded/shielded) was 88/86 mJ for computed tomography (CT) brain, 64/60 mJ for CT cervical spine, and 289/260 mJ for CT chest scanning. An increase in image noise could be observed in the ranges were bismuth shielding was applied. The observed reduction of organ dose and total energy imparted could be achieved more efficiently by a reduction of tube current. The application of in-plane selective shielding is therefore discouraged.

Entities:  

Mesh:

Year:  2006        PMID: 16604323     DOI: 10.1007/s00330-006-0217-2

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  15 in total

1.  Efficacy of breast shielding during CT of the head.

Authors:  Z Brnić; B Vekić; A Hebrang; P Anić
Journal:  Eur Radiol       Date:  2003-06-25       Impact factor: 5.315

2.  Reproducibility of multi-slice spiral computed tomography scans: an experimental study.

Authors:  Marcel van Straten; Henk W Venema; Joris Hartman; Gerard J den Heeten; Cornelis A Grimbergen
Journal:  Med Phys       Date:  2004-10       Impact factor: 4.071

3.  Use of an automatic exposure control mechanism for dose optimization in multi-detector row CT examinations: clinical evaluation.

Authors:  Tom H Mulkens; Patrick Bellinck; Michel Baeyaert; Dirk Ghysen; Xavier Van Dijck; Elvier Mussen; Caroline Venstermans; Jean-Luc Termote
Journal:  Radiology       Date:  2005-08-26       Impact factor: 11.105

4.  The effect of z overscanning on patient effective dose from multidetector helical computed tomography examinations.

Authors:  A Tzedakis; J Damilakis; K Perisinakis; J Stratakis; N Gourtsoyiannis
Journal:  Med Phys       Date:  2005-06       Impact factor: 4.071

5.  The breast: in-plane x-ray protection during diagnostic thoracic CT--shielding with bismuth radioprotective garments.

Authors:  K D Hopper; S H King; M E Lobell; T R TenHave; J S Weaver
Journal:  Radiology       Date:  1997-12       Impact factor: 11.105

6.  Would thyroid and breast shielding be beneficial in CT of the head?

Authors:  T Beaconsfield; R Nicholson; A Thornton; A Al-Kutoubi
Journal:  Eur Radiol       Date:  1998       Impact factor: 5.315

7.  Radioprotection to the eye during CT scanning.

Authors:  K D Hopper; J D Neuman; S H King; A R Kunselman
Journal:  AJNR Am J Neuroradiol       Date:  2001 Jun-Jul       Impact factor: 3.825

8.  The tissue-equivalence of the Alderson Rando anthropomorphic phantom for x-rays of diagnostic qualities.

Authors:  P C Shrimpton; B F Wall; E S Fisher
Journal:  Phys Med Biol       Date:  1981-01       Impact factor: 3.609

9.  Monte Carlo calculation of radiation dose in CT examinations using phantom and patient tomographic models.

Authors:  M Salvadó; M López; J J Morant; A Calzado
Journal:  Radiat Prot Dosimetry       Date:  2005       Impact factor: 0.972

10.  Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regions.

Authors:  H Greess; H Wolf; U Baum; M Lell; M Pirkl; W Kalender; W A Bautz
Journal:  Eur Radiol       Date:  2000       Impact factor: 5.315

View more
  30 in total

1.  The use of breast shielding for dose reduction in pediatric CT: arguments against the proposition.

Authors:  Jacob Geleijns; Jia Wang; Cynthia McCollough
Journal:  Pediatr Radiol       Date:  2010-08-21

2.  Bismuth shielding in CT: support for use in children.

Authors:  Sangroh Kim; Donald P Frush; Terry T Yoshizumi
Journal:  Pediatr Radiol       Date:  2010-08-24

3.  Effect of bismuth breast shielding on radiation dose and image quality in coronary CT angiography.

Authors:  Andrew J Einstein; Carl D Elliston; Daniel W Groves; Bin Cheng; Steven D Wolff; Gregory D N Pearson; M Robert Peters; Lynne L Johnson; Sabahat Bokhari; Gary W Johnson; Ketan Bhatia; Theodore Pozniakoff; David J Brenner
Journal:  J Nucl Cardiol       Date:  2011-11-09       Impact factor: 5.952

Review 4.  Radiation safety.

Authors:  Donald P Frush
Journal:  Pediatr Radiol       Date:  2009-06

Review 5.  Pediatric abdominal CT angiography.

Authors:  Donald P Frush
Journal:  Pediatr Radiol       Date:  2008-05

Review 6.  Coronary CT angiography: Dose reduction strategies.

Authors:  Akmal Sabarudin; Zhonghua Sun
Journal:  World J Cardiol       Date:  2013-12-26

7.  The effects of bismuth breast shields in conjunction with automatic tube current modulation in CT imaging.

Authors:  Sabah Servaes; Xiaowei Zhu
Journal:  Pediatr Radiol       Date:  2013-05-23

8.  A method to generate equivalent energy spectra and filtration models based on measurement for multidetector CT Monte Carlo dosimetry simulations.

Authors:  Adam C Turner; Di Zhang; Hyun J Kim; John J DeMarco; Chris H Cagnon; Erin Angel; Dianna D Cody; Donna M Stevens; Andrew N Primak; Cynthia H McCollough; Michael F McNitt-Gray
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

9.  Dose reduction in multislice CT by means of bismuth shields: results of in vivo measurements and computed evaluation.

Authors:  P Catuzzo; S Aimonetto; G Fanelli; P Marchisio; T Meloni; L Mistretta; M Pasquino; E Richetta; S Tofani
Journal:  Radiol Med       Date:  2009-12-14       Impact factor: 3.469

10.  Dose reduction in CT using bismuth shielding: measurements and Monte Carlo simulations.

Authors:  Kyung-Hwan Chang; Wonho Lee; Dong-Myung Choo; Choon-Sik Lee; Youhyun Kim
Journal:  Radiat Prot Dosimetry       Date:  2009-12-03       Impact factor: 0.972

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.