Literature DB >> 9888054

Radiation exposure in spiral computed tomography. Dose distribution and dose reduction.

N Hidajat1, J Mäurer, R J Schröder, M Wolf, T Vogl, R Felix.   

Abstract

RATIONALE AND
OBJECTIVES: The authors investigate the dose distribution of spiral and conventional computed tomography (CT) with film densitometry and to present a new method of evaluating the possibility of dose savings with spiral CT.
METHODS: Films were exposed in a cuboid polymethyl-methacrylate phantom in conventional and spiral scan technique. Axial density profiles were obtained by digitizing the films using a fluorescent light scanner. The ratio of the number of rotations in spiral CT to the number of slices in conventional CT was calculated.
RESULTS: In spiral CT with a pitch of 2, the densities in all points were lower than those in corresponding points in spiral CT with a pitch of 1 and in conventional CT with slice distance equal to slice thickness. A pitch of 1.5 in spiral CT led to a dose reduction of 14% to 30% compared with conventional CT.
CONCLUSIONS: Increasing the pitch in spiral CT leads to a reduction of both integral dose and absorbed doses within the examined body region. The reduction of the integral dose can be significant, especially in cases where slice overlapping is diagnostically advantageous.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 9888054     DOI: 10.1097/00004424-199901000-00008

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  4 in total

1.  Efficacy of breast shielding during CT of the head.

Authors:  Z Brnić; B Vekić; A Hebrang; P Anić
Journal:  Eur Radiol       Date:  2003-06-25       Impact factor: 5.315

2.  Model-based reconstruction algorithm in the detection of acute trauma-related lesions in brain CT examinations.

Authors:  Andrea De Vito; Cesare Maino; Sophie Lombardi; Maria Ragusi; Cammillo Talei Franzesi; Davide Ippolito; Sandro Sironi
Journal:  Neuroradiol J       Date:  2021-04-19

Review 3.  Computed tomography and patient risk: Facts, perceptions and uncertainties.

Authors:  Stephen P Power; Fiachra Moloney; Maria Twomey; Karl James; Owen J O'Connor; Michael M Maher
Journal:  World J Radiol       Date:  2016-12-28

4.  Comparison of radiation doses using weight-based protocol and dose modulation techniques for patients undergoing biphasic abdominal computed tomography examinations.

Authors:  Roshan S Livingstone; Paul M Dinakaran; Rekha S Cherian; Anu Eapen
Journal:  J Med Phys       Date:  2009-10
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.