Literature DB >> 10847378

A new needle-crystalline computed radiography detector.

P Leblans1, L Struye, P Willems.   

Abstract

The most successful digital radiography detectors to date have been storage phosphor plates used in computed radiography (CR). The detector is cheap, has good producibility, and is robust. Direct radiography (DR) systems are being developed based on flat-panel technology. Better image quality is claimed for some DR systems. On the other hand, DR detectors have low producibility and robustness, and a high price. A new CR detector is being developed at Agfa that combines the advantages of CR and DR. It is a storage phosphor plate made up of needle-shaped crystals. The phosphor efficiently converts absorbed x-ray quanta into photostimulable centers for efficient read out. It has a large dynamic range and its emission is efficiently detected with both photomultiplier tube (PMT) and charge coupled device (CCD). It is shown that CR systems based on the new detector offer image quality that matches that of the best DR systems.

Entities:  

Mesh:

Year:  2000        PMID: 10847378      PMCID: PMC3453297          DOI: 10.1007/bf03167640

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  2 in total

1.  Signal, noise power spectrum, and detective quantum efficiency of indirect-detection flat-panel imagers for diagnostic radiology.

Authors:  J H Siewerdsen; L E Antonuk; Y el-Mohri; J Yorkston; W Huang; I A Cunningham
Journal:  Med Phys       Date:  1998-05       Impact factor: 4.071

2.  DQE(f) of four generations of computed radiography acquisition devices.

Authors:  J T Dobbins; D L Ergun; L Rutz; D A Hinshaw; H Blume; D C Clark
Journal:  Med Phys       Date:  1995-10       Impact factor: 4.071

  2 in total
  12 in total

1.  Theoretical and empirical investigations of KCl : Eu2+ for nearly water-equivalent radiotherapy dosimetry.

Authors:  Yuanshui Zheng; Zhaohui Han; Joseph P Driewer; Daniel A Low; H Harold Li
Journal:  Med Phys       Date:  2010-01       Impact factor: 4.071

2.  Optimization of dose and image quality for computed radiography and digital radiography.

Authors:  Charles E Willis
Journal:  J Digit Imaging       Date:  2007-03       Impact factor: 4.056

3.  Impact of the digitalisation of mammography on performance parameters and breast dose in the Flemish Breast Cancer Screening Programme.

Authors:  Lore Timmermans; An De Hauwere; Klaus Bacher; Hilde Bosmans; Kim Lemmens; Luc Bleyen; Erik Van Limbergen; Patrick Martens; Andre Van Steen; Griet Mortier; Koen Van Herck; Hubert Thierens
Journal:  Eur Radiol       Date:  2014-05-10       Impact factor: 5.315

4.  The role of oxygen in the photostimulation luminescence process of europium doped potassium chloride.

Authors:  Zhiyan Xiao; Thomas R Mazur; Joseph P Driewer; H Harold Li
Journal:  Radiat Meas       Date:  2015-05-01       Impact factor: 1.898

5.  Radiation hardness of the storage phosphor europium doped potassium chloride for radiation therapy dosimetry.

Authors:  Joseph P Driewer; Haijian Chen; Andres Osvet; Daniel A Low; H Harold Li
Journal:  Med Phys       Date:  2011-08       Impact factor: 4.071

6.  The role of activator concentration and precipitate formation on optical and dosimetric properties of KCl:Eu(2+) storage phosphor detectors.

Authors:  Rachael A Hansel; Zhiyan Xiao; Yanle Hu; Olga Green; Deshan Yang; H Harold Li
Journal:  Med Phys       Date:  2013-09       Impact factor: 4.071

7.  Two-dimensional high spatial-resolution dosimeter using europium doped potassium chloride: a feasibility study.

Authors:  H Harold Li; Joseph P Driewer; Zhaohui Han; Daniel A Low; Deshan Yang; Zhiyan Xiao
Journal:  Phys Med Biol       Date:  2014-03-20       Impact factor: 3.609

8.  Performance of KCl:Eu2+ storage phosphor dosimeters for low-dose measurements.

Authors:  H Harold Li; Zhiyan Xiao; Rachael Hansel; Nels Knutson; Deshan Yang
Journal:  Phys Med Biol       Date:  2013-06-05       Impact factor: 3.609

9.  Quantitative megavoltage radiation therapy dosimetry using the storage phosphor KCl: Eu2+.

Authors:  Zhaohui Han; Joseph P Driewer; Yuanshui Zheng; Daniel A Low; H Harold Li
Journal:  Med Phys       Date:  2009-08       Impact factor: 4.071

Review 10.  Digital chest radiography: an update on modern technology, dose containment and control of image quality.

Authors:  Cornelia Schaefer-Prokop; Ulrich Neitzel; Henk W Venema; Martin Uffmann; Mathias Prokop
Journal:  Eur Radiol       Date:  2008-04-23       Impact factor: 5.315

View more