Performance of KCl:Eu2+ storage phosphor dosimeters for low-dose measurements.

H Harold Li1, Zhiyan Xiao, Rachael Hansel, Nels Knutson, Deshan Yang.   

Abstract

Recent research has demonstrated that europium doped potassium chloride (KCl:Eu(2+)) storage phosphor material has the potential to become the physical foundation of a novel and reusable dosimetry system using either film-like devices or devices similar to thermoluminescent dosimeter chips. The purposes of this work are to quantify the performance of KCl:Eu(2+) prototype dosimeters for low-dose measurements and to demonstrate how it can be incorporated into clinical application for in vivo peripheral dose measurements. Pellet-style KCl:Eu(2+) dosimeters, 6 mm in diameter, and 1 mm thick, were fabricated in-house for this study. The dosimeters were read using a laboratory photostimulated luminescence detection system. KCl:Eu(2+) prototype storage phosphor dosimeter was capable of measuring a dose-to-water as low as 0.01 cGy from a 6 MV photon beam with a signal-to-noise ratio greater than 6. A pre-readout thermal annealing procedure enabled the dosimeter to be read within an hour post-irradiation. After receiving large accumulated doses (~10 kGy), the dosimeters retained linear response in the low-dose region with only a 20% loss of sensitivity comparing to a fresh sample (zero Gy history). The energy dependence encountered during low-dose peripheral measurements could be accounted for via a single point outside-field calibration per each beam quality. With further development the KCl:Eu(2+-)-based dosimeter could become a versatile and durable dosimetry tool with large dynamic range (sub-cGy to 100 Gy).

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23735856      PMCID: PMC3774152          DOI: 10.1088/0031-9155/58/12/4357

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  17 in total

1.  AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams.

Authors:  P R Almond; P J Biggs; B M Coursey; W F Hanson; M S Huq; R Nath; D W Rogers
Journal:  Med Phys       Date:  1999-09       Impact factor: 4.071

Review 2.  The physics of computed radiography.

Authors:  J A Rowlands
Journal:  Phys Med Biol       Date:  2002-12-07       Impact factor: 3.609

3.  Peripheral dose measurement with a MOSFET detector.

Authors:  Martin J Butson; Tsang Cheung; Peter K N Yu
Journal:  Appl Radiat Isot       Date:  2005-04       Impact factor: 1.513

4.  Dose response of BaFBrl: Eu2+ storage phosphor plates exposed to megavoltage photon beams.

Authors:  H Harold Li; Albin L Gonzalez; Huaying Ji; Dennis M Duggan
Journal:  Med Phys       Date:  2007-01       Impact factor: 4.071

5.  A Monte Carlo model for out-of-field dose calculation from high-energy photon therapy.

Authors:  Stephen F Kry; Uwe Titt; David Followill; Falk Pönisch; Oleg N Vassiliev; R Allen White; Marilyn Stovall; Mohammad Salehpour
Journal:  Med Phys       Date:  2007-09       Impact factor: 4.071

6.  Spatial correlation and photostimulability of defect centers in the x-ray-storage phosphor BaFBr:Eu2+

Authors: 
Journal:  Phys Rev B Condens Matter       Date:  1991-11-01

7.  Variations in photon energy spectra of a 6 MV beam and their impact on TLD response.

Authors:  Sarah B Scarboro; David S Followill; Rebecca M Howell; Stephen F Kry
Journal:  Med Phys       Date:  2011-05       Impact factor: 4.071

8.  Dose-response curve of EBT, EBT2, and EBT3 radiochromic films to synchrotron-produced monochromatic x-ray beams.

Authors:  Thomas A D Brown; Kenneth R Hogstrom; Diane Alvarez; Kenneth L Matthews; Kyungmin Ham; Joseph P Dugas
Journal:  Med Phys       Date:  2012-12       Impact factor: 4.071

9.  DQE(f) of four generations of computed radiography acquisition devices.

Authors:  J T Dobbins; D L Ergun; L Rutz; D A Hinshaw; H Blume; D C Clark
Journal:  Med Phys       Date:  1995-10       Impact factor: 4.071

10.  Characterization of optically stimulated luminescent dosimeters, OSLDs, for clinical dosimetric measurements.

Authors:  Paul A Jursinic
Journal:  Med Phys       Date:  2007-12       Impact factor: 4.071

View more
  2 in total

1.  Two-dimensional high spatial-resolution dosimeter using europium doped potassium chloride: a feasibility study.

Authors:  H Harold Li; Joseph P Driewer; Zhaohui Han; Daniel A Low; Deshan Yang; Zhiyan Xiao
Journal:  Phys Med Biol       Date:  2014-03-20       Impact factor: 3.609

2.  Development of a storage phosphor imaging system for proton pencil beam spot profile determination.

Authors:  Jufri Setianegara; Thomas R Mazur; Yao Hao; Deshan Yang; H Harold Li
Journal:  Med Phys       Date:  2021-08-10       Impact factor: 4.506

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.