Two-dimensional high spatial-resolution dosimeter using europium doped potassium chloride: a feasibility study.

H Harold Li1, Joseph P Driewer, Zhaohui Han, Daniel A Low, Deshan Yang, Zhiyan Xiao.   

Abstract

Recent research has shown that KCl:Eu²⁺ has great potential for use in megavoltage radiation therapy dosimetry because this material exhibits excellent storage performance and is reusable due to strong radiation hardness. This work reports the authors' attempts to fabricate 2D KCl:Eu²⁺ storage phosphor films (SPFs) using both a physical vapor deposition (PVD) method and a tape casting method. X-ray diffraction analysis showed that a 10 µm thick PVD sample was composed of highly crystalline KCl. No additional phases were observed, suggesting that the europium activator had been completely incorporated into the KCl matrix. Photostimulated luminescence and photoluminescence spectra suggested that F (Cl(-)) centers were the electron storage centers post x-ray irradiation and that Eu²⁺ cations acted as luminescence centers in the photostimulation process. The 150 µm thick casted KCl:Eu²⁺ SPF showed sub-millimeter spatial-resolution. Monte Carlo simulations further demonstrated that the admixture of 20% KCl:Eu²⁺ and 80% low Z polymer binder exhibited almost no energy-dependence in a 6 MV beam. KCl:Eu²⁺ pellet samples showed a large dynamic range from 0.01 cGy to 60 Gy dose-to-water, and saturated at approximately 500 Gy as a result of KCl's intrinsic high radiation hardness. Taken together, this work provides strong evidence that KCl:Eu²⁺-based SPF with associated readout apparatus could result in a novel electronic film system that has all the desirable features associated with classic radiographic film and, importantly, water equivalence and the capability of permanent identification of each detector.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24651448      PMCID: PMC4019811          DOI: 10.1088/0031-9155/59/8/1899

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  17 in total

1.  Monte Carlo calculation of nine megavoltage photon beam spectra using the BEAM code.

Authors:  Daryoush Sheikh-Bagheri; D W O Rogers
Journal:  Med Phys       Date:  2002-03       Impact factor: 4.071

2.  Predicting energy response of radiographic film in a 6 MV x-ray beam using Monte Carlo calculated fluence spectra and absorbed dose.

Authors:  Asa Palm; Assen S Kirov; Thomas LoSasso
Journal:  Med Phys       Date:  2004-12       Impact factor: 4.071

3.  Pencil beam approach for correcting the energy dependence artifact in film dosimetry for IMRT verification.

Authors:  Assen S Kirov; Gregory Caravelli; Asa Palm; Chen Chui; Thomas LoSasso
Journal:  Med Phys       Date:  2006-10       Impact factor: 4.071

4.  TG-69: radiographic film for megavoltage beam dosimetry.

Authors:  Sujatha Pai; Indra J Das; James F Dempsey; Kwok L Lam; Thomas J Losasso; Arthur J Olch; Jatinder R Palta; Lawrence E Reinstein; Dan Ritt; Ellen E Wilcox
Journal:  Med Phys       Date:  2007-06       Impact factor: 4.071

5.  Dose response of BaFBrl: Eu2+ storage phosphor plates exposed to megavoltage photon beams.

Authors:  H Harold Li; Albin L Gonzalez; Huaying Ji; Dennis M Duggan
Journal:  Med Phys       Date:  2007-01       Impact factor: 4.071

Review 6.  Dosimetry tools and techniques for IMRT.

Authors:  Daniel A Low; Jean M Moran; James F Dempsey; Lei Dong; Mark Oldham
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

7.  Radiation hardness of the storage phosphor europium doped potassium chloride for radiation therapy dosimetry.

Authors:  Joseph P Driewer; Haijian Chen; Andres Osvet; Daniel A Low; H Harold Li
Journal:  Med Phys       Date:  2011-08       Impact factor: 4.071

8.  X ray storage performance of KCl:Eu2+ with high cumulated dose.

Authors:  Rachael A Hansel; Zhiyan Xiao; Lei Zhang; H Harold Li
Journal:  Nucl Instrum Methods Phys Res B       Date:  2014-05-01       Impact factor: 1.377

9.  Performance of KCl:Eu2+ storage phosphor dosimeters for low-dose measurements.

Authors:  H Harold Li; Zhiyan Xiao; Rachael Hansel; Nels Knutson; Deshan Yang
Journal:  Phys Med Biol       Date:  2013-06-05       Impact factor: 3.609

10.  Quantitative megavoltage radiation therapy dosimetry using the storage phosphor KCl: Eu2+.

Authors:  Zhaohui Han; Joseph P Driewer; Yuanshui Zheng; Daniel A Low; H Harold Li
Journal:  Med Phys       Date:  2009-08       Impact factor: 4.071

View more
  3 in total

1.  The role of oxygen in the photostimulation luminescence process of europium doped potassium chloride.

Authors:  Zhiyan Xiao; Thomas R Mazur; Joseph P Driewer; H Harold Li
Journal:  Radiat Meas       Date:  2015-05-01       Impact factor: 1.898

2.  Development of a storage phosphor imaging system for proton pencil beam spot profile determination.

Authors:  Jufri Setianegara; Thomas R Mazur; Yao Hao; Deshan Yang; H Harold Li
Journal:  Med Phys       Date:  2021-08-10       Impact factor: 4.506

3.  MgO:Li,Ce,Sm as a high-sensitivity material for Optically Stimulated Luminescence dosimetry.

Authors:  Luiz C Oliveira; Eduardo G Yukihara; Oswaldo Baffa
Journal:  Sci Rep       Date:  2016-04-14       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.