Literature DB >> 25897274

The role of oxygen in the photostimulation luminescence process of europium doped potassium chloride.

Zhiyan Xiao1, Thomas R Mazur1, Joseph P Driewer1, H Harold Li1.   

Abstract

A recent suggestion that europium doped potassium chloride (KCl:Eu2+) has the potential to significantly advance the state-of-the-art in radiation therapy dosimetry has generated a renewed interest in a classic storage phosphor material. The purposes of this work are to investigate the role of oxygen in the photostimulation luminescence (PSL) process and to determine if both increased PSL yield and improved temporal stability could be realized in KCl:Eu2+ by incorporating oxygen in the material fabrication process. Regardless of synthesis atmosphere, air or pure nitrogen, PSL amplitude shows a maximum at 1.0 mol % Eu. Depending on europium concentration, dosimeters fabricated in air exhibit stronger PSL by a factor of 2 to 4 compared to those made in N2. There is no change in PSL stimulation spectrum while noticeable shifts in both photoluminescence and PSL emission spectra are observed for air versus nitrogen. Almost all charge-storage centers are spatially correlated, suggesting oxygen's stabilization role in the PSL process. However, oxygen alone does not improve material's temporal stability in the first few hours post irradiation at room temperature, probably because a significant portion of radiation-induced holes are stored in the Vk centers which are mobile.

Entities:  

Year:  2015        PMID: 25897274      PMCID: PMC4400662          DOI: 10.1016/j.radmeas.2015.03.013

Source DB:  PubMed          Journal:  Radiat Meas        ISSN: 1350-4487            Impact factor:   1.898


  10 in total

1.  A new needle-crystalline computed radiography detector.

Authors:  P Leblans; L Struye; P Willems
Journal:  J Digit Imaging       Date:  2000-05       Impact factor: 4.056

2.  Creation of photostimulable centers in BaFBr:Eu2+ single crystals by vacuum ultraviolet radiation.

Authors: 
Journal:  Phys Rev Lett       Date:  1990-11-05       Impact factor: 9.161

3.  Homogeneity of Gafchromic EBT2 film.

Authors:  Bernadette Hartmann; Mária Martisiková; Oliver Jäkel
Journal:  Med Phys       Date:  2010-04       Impact factor: 4.071

4.  Evaluation of a computed radiography system for megavoltage photon beam dosimetry.

Authors:  Arthur J Olch
Journal:  Med Phys       Date:  2005-09       Impact factor: 4.071

5.  Important considerations for radiochromic film dosimetry with flatbed CCD scanners and EBT GAFCHROMIC film.

Authors:  Bart D Lynch; Jakub Kozelka; Manisha K Ranade; Jonathan G Li; William E Simon; James F Dempsey
Journal:  Med Phys       Date:  2006-12       Impact factor: 4.071

6.  TG-69: radiographic film for megavoltage beam dosimetry.

Authors:  Sujatha Pai; Indra J Das; James F Dempsey; Kwok L Lam; Thomas J Losasso; Arthur J Olch; Jatinder R Palta; Lawrence E Reinstein; Dan Ritt; Ellen E Wilcox
Journal:  Med Phys       Date:  2007-06       Impact factor: 4.071

7.  Spatial correlation and photostimulability of defect centers in the x-ray-storage phosphor BaFBr:Eu2+

Authors: 
Journal:  Phys Rev B Condens Matter       Date:  1991-11-01

8.  The role of activator concentration and precipitate formation on optical and dosimetric properties of KCl:Eu(2+) storage phosphor detectors.

Authors:  Rachael A Hansel; Zhiyan Xiao; Yanle Hu; Olga Green; Deshan Yang; H Harold Li
Journal:  Med Phys       Date:  2013-09       Impact factor: 4.071

9.  X ray storage performance of KCl:Eu2+ with high cumulated dose.

Authors:  Rachael A Hansel; Zhiyan Xiao; Lei Zhang; H Harold Li
Journal:  Nucl Instrum Methods Phys Res B       Date:  2014-05-01       Impact factor: 1.377

10.  Two-dimensional high spatial-resolution dosimeter using europium doped potassium chloride: a feasibility study.

Authors:  H Harold Li; Joseph P Driewer; Zhaohui Han; Daniel A Low; Deshan Yang; Zhiyan Xiao
Journal:  Phys Med Biol       Date:  2014-03-20       Impact factor: 3.609

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.