Literature DB >> 8137076

Two configurations of the four-ring birdcage coil for 1H imaging and 1H-decoupled 31P spectroscopy of the human head.

J Murphy-Boesch1, R Srinivasan, L Carvajal, T R Brown.   

Abstract

The four-ring birdcage resonator, a new class of dual-tuned birdcage resonators, is described. We report two configurations of the coil: the low-pass, high-pass (LP-HP) and the low-pass, low-pass (LP-LP), both of which can be operated in dual quadrature mode at 1.5 T. As head coils, both configurations exhibit greatly reduced tuning interactions between frequencies, permitting rapid, noniterative tuning. Compared with single-tuned, two-ring birdcage resonators of similar volume, the sensitivity and transmitter efficiencies of the resonators are better than 85% for the proton frequency and the same to within 5% for the phosphorus frequency. Circuit models have been developed to refine coil tuning and aid the calculation of B1 field contour plots. Both configurations have been used for integrated examinations involving acquisition of high-quality 1H images and 1H-decoupled 31P CSI spectra of the human head. A scaled-down version of the LP-LP configuration has been demonstrated for use with the human calf.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8137076     DOI: 10.1006/jmrb.1994.1017

Source DB:  PubMed          Journal:  J Magn Reson B        ISSN: 1064-1866


  15 in total

1.  A nested phosphorus and proton coil array for brain magnetic resonance imaging and spectroscopy.

Authors:  Ryan Brown; Karthik Lakshmanan; Guillaume Madelin; Prodromos Parasoglou
Journal:  Neuroimage       Date:  2015-09-13       Impact factor: 6.556

2.  Design and numerical evaluation of a volume coil array for parallel MR imaging at ultrahigh fields.

Authors:  Yong Pang; Ernest W H Wong; Baiying Yu; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2014-02

3.  Dual resonant birdcage coils for 1H detected 13C microscopic imaging at 11.7 T.

Authors:  A M Hudson; W Köckenberger; R W Bowtell
Journal:  MAGMA       Date:  2000-06       Impact factor: 2.310

4.  A practical multinuclear transceiver volume coil for in vivo MRI/MRS at 7 T.

Authors:  Chunsheng Wang; Ye Li; Bing Wu; Duan Xu; Sarah J Nelson; Daniel B Vigneron; Xiaoliang Zhang
Journal:  Magn Reson Imaging       Date:  2011-11-03       Impact factor: 2.546

5.  Radiofrequency coils for musculoskeletal magnetic resonance imaging.

Authors:  Kambiz A Asher; Neal K Bangerter; Ronald D Watkins; Garry E Gold
Journal:  Top Magn Reson Imaging       Date:  2010-10

6.  Common-mode differential-mode (CMDM) method for double-nuclear MR signal excitation and reception at ultrahigh fields.

Authors:  Yong Pang; Xiaoliang Zhang; Zhentian Xie; Chunsheng Wang; Daniel B Vigneron
Journal:  IEEE Trans Med Imaging       Date:  2011-06-20       Impact factor: 10.048

7.  Double-tuned four-ring birdcage resonators for in vivo 31P-nuclear magnetic resonance spectroscopy at 11.75 T.

Authors:  T Lanz; M von Kienlin; W Behr; A Haase
Journal:  MAGMA       Date:  1997-09       Impact factor: 2.310

8.  Design of a nested eight-channel sodium and four-channel proton coil for 7T knee imaging.

Authors:  Ryan Brown; Guillaume Madelin; Riccardo Lattanzi; Gregory Chang; Ravinder R Regatte; Daniel K Sodickson; Graham C Wiggins
Journal:  Magn Reson Med       Date:  2012-08-08       Impact factor: 4.668

Review 9.  High-performance radiofrequency coils for (23)Na MRI: brain and musculoskeletal applications.

Authors:  Graham C Wiggins; Ryan Brown; Karthik Lakshmanan
Journal:  NMR Biomed       Date:  2015-09-24       Impact factor: 4.044

10.  Optimization and comparison of two practical dual-tuned birdcage configurations for quantitative assessment of articular cartilage with sodium magnetic resonance imaging.

Authors:  Gunthard Lykowsky; Flavio Carinci; Markus Düring; Daniel Weber; Peter M Jakob; Daniel Haddad
Journal:  Quant Imaging Med Surg       Date:  2015-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.