Abstract

A high signal-to-noise ratio (SNR) in 31P-nuclear magnetic resonance (31P-NMR) spectroscopy can be obtained only with good B0-field homogeneity and optimal coil sensitivity. This demands double-tuned coils with a highly sensitive 31P channel and an additional 1H channel for 1H-magnetic resonance imaging, shimming, 1H decoupling, and nuclear Overhauser enhancement (NOE). For studies on an 11.75 T magnet, we built coils derived from the four-ring birdcage design originally described by Murphy-Boesch. A comparison with conventional, single-tuned coils shows that, in spite of double tuning, there is no significant loss in 31P sensitivity while the 1H channel provides the requested performance. The coil design offers the advantage of circular polarization on both channels.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9351028     DOI: 10.1007/bf02594587

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  1 in total

1.  Two configurations of the four-ring birdcage coil for 1H imaging and 1H-decoupled 31P spectroscopy of the human head.

Authors:  J Murphy-Boesch; R Srinivasan; L Carvajal; T R Brown
Journal:  J Magn Reson B       Date:  1994-02
  1 in total
  4 in total

1.  A nested phosphorus and proton coil array for brain magnetic resonance imaging and spectroscopy.

Authors:  Ryan Brown; Karthik Lakshmanan; Guillaume Madelin; Prodromos Parasoglou
Journal:  Neuroimage       Date:  2015-09-13       Impact factor: 6.556

2.  Dual resonant birdcage coils for 1H detected 13C microscopic imaging at 11.7 T.

Authors:  A M Hudson; W Köckenberger; R W Bowtell
Journal:  MAGMA       Date:  2000-06       Impact factor: 2.310

3.  A flexible nested sodium and proton coil array with wideband matching for knee cartilage MRI at 3T.

Authors:  Ryan Brown; Karthik Lakshmanan; Guillaume Madelin; Leeor Alon; Gregory Chang; Daniel K Sodickson; Ravinder R Regatte; Graham C Wiggins
Journal:  Magn Reson Med       Date:  2015-10-26       Impact factor: 4.668

4.  Uncompromised MRI of knee cartilage while incorporating sensitive sodium MRI.

Authors:  S Brinkhof; A Ali Haghnejad; K Ito; K Markenroth Bloch; D W J Klomp
Journal:  NMR Biomed       Date:  2019-09-10       Impact factor: 4.044

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.