Literature DB >> 22055858

A practical multinuclear transceiver volume coil for in vivo MRI/MRS at 7 T.

Chunsheng Wang1, Ye Li, Bing Wu, Duan Xu, Sarah J Nelson, Daniel B Vigneron, Xiaoliang Zhang.   

Abstract

A practical multinuclear transceiver RF volume coil with improved efficiency for in vivo small animal (1)H/(13)C/(23)Na MR applications at the ultrahigh magnetic field of 7 T is reported. In the proposed design, the coil's resonance frequencies for (1)H and (13)C are realized by using a traditional double-tuned approach, while the resonant frequency for (23)Na, which is only some 4 MHz away from the (13)C frequency, is tuned based upon (13)C channel by easy-operating capacitive "frequency switches". In contrast to the traditional triple-tuned volume coil, the volume coil with the proposed design possesses less number of resonances, which helps improve the coil efficiency and alleviate the design and operation difficulties. This coil design strategy is advantageous and well suitable for multinuclear MR imaging and spectroscopy studies, particularly in the case where Larmor frequencies of nuclei in question are not separate enough. The prototype multinuclear coil was demonstrated in the desired unshielded design for easy construction and experiment implementation at 7 T. The design method may provide a practical and robust solution to designing multinuclear RF volume coils for in vivo MR imaging and spectroscopy at ultrahigh fields. Finite difference time domain method simulations for evaluating the design and 7-T MR experiment results acquired using the prototype coil are presented.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 22055858      PMCID: PMC3277811          DOI: 10.1016/j.mri.2011.08.007

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  33 in total

1.  Imaging brain function in humans at 7 Tesla.

Authors:  E Yacoub; A Shmuel; J Pfeuffer; P F Van De Moortele; G Adriany; P Andersen; J T Vaughan; H Merkle; K Ugurbil; X Hu
Journal:  Magn Reson Med       Date:  2001-04       Impact factor: 4.668

2.  Computational analysis of the high pass birdcage resonator: finite difference time domain simulations for high-field MRI.

Authors:  T S Ibrahim; R Lee; B A Baertlein; Y Yu; P M Robitaille
Journal:  Magn Reson Imaging       Date:  2000-09       Impact factor: 2.546

3.  Application of finite difference time domain method for the design of birdcage RF head coils using multi-port excitations.

Authors:  T S Ibrahim; R Lee; B A Baertlein; A Kangarlu; P L Robitaille
Journal:  Magn Reson Imaging       Date:  2000-07       Impact factor: 2.546

4.  7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images.

Authors:  J T Vaughan; M Garwood; C M Collins; W Liu; L DelaBarre; G Adriany; P Andersen; H Merkle; R Goebel; M B Smith; K Ugurbil
Journal:  Magn Reson Med       Date:  2001-07       Impact factor: 4.668

5.  Microstrip RF surface coil design for extremely high-field MRI and spectroscopy.

Authors:  X Zhang; K Ugurbil; W Chen
Journal:  Magn Reson Med       Date:  2001-09       Impact factor: 4.668

6.  A microstrip transmission line volume coil for human head MR imaging at 4T.

Authors:  Xiaoliang Zhang; Kamil Ugurbil; Wei Chen
Journal:  J Magn Reson       Date:  2003-04       Impact factor: 2.229

7.  Development of (17)O NMR approach for fast imaging of cerebral metabolic rate of oxygen in rat brain at high field.

Authors:  Xiao-Hong Zhu; Yi Zhang; Run-Xia Tian; Hao Lei; Nanyin Zhang; Xiaoliang Zhang; Hellmut Merkle; Kamil Ugurbil; Wei Chen
Journal:  Proc Natl Acad Sci U S A       Date:  2002-09-19       Impact factor: 11.205

8.  Assessment of mitochondrial energy coupling in vivo by 13C/31P NMR.

Authors:  B M Jucker; S Dufour; J Ren; X Cao; S F Previs; B Underhill; K S Cadman; G I Shulman
Journal:  Proc Natl Acad Sci U S A       Date:  2000-06-06       Impact factor: 11.205

9.  Increase in signal-to-noise ratio of > 10,000 times in liquid-state NMR.

Authors:  Jan H Ardenkjaer-Larsen; Björn Fridlund; Andreas Gram; Georg Hansson; Lennart Hansson; Mathilde H Lerche; Rolf Servin; Mikkel Thaning; Klaes Golman
Journal:  Proc Natl Acad Sci U S A       Date:  2003-08-20       Impact factor: 11.205

10.  In vivo 31P magnetic resonance spectroscopy of human brain at 7 T: an initial experience.

Authors:  Hao Lei; Xiao-Hong Zhu; Xiao-Liang Zhang; Kamil Ugurbil; Wei Chen
Journal:  Magn Reson Med       Date:  2003-02       Impact factor: 4.668

View more
  11 in total

1.  Cell tracking using (19)F magnetic resonance imaging: technical aspects and challenges towards clinical applications.

Authors:  Houshang Amiri; Mangala Srinivas; Andor Veltien; Mark J van Uden; I Jolanda M de Vries; Arend Heerschap
Journal:  Eur Radiol       Date:  2014-11-06       Impact factor: 5.315

2.  A monopole/loop dual-tuned RF coil for ultrahigh field MRI.

Authors:  Xinqiang Yan; Rong Xue; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2014-08

3.  Design and numerical evaluation of a volume coil array for parallel MR imaging at ultrahigh fields.

Authors:  Yong Pang; Ernest W H Wong; Baiying Yu; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2014-02

Review 4.  Magnetic resonance imaging for lung cancer screen.

Authors:  Yi-Xiang J Wang; Gladys G Lo; Jing Yuan; Peder E Z Larson; Xiaoliang Zhang
Journal:  J Thorac Dis       Date:  2014-09       Impact factor: 2.895

5.  Electromagnetic Field and Radio Frequency Circuit Co-Simulation for Magnetic Resonance Imaging Dual-Tuned Radio Frequency Coils.

Authors:  Nan Li; Shengping Liu; Xiaoqing Hu; Chao Luo; Xiaoliang Zhang; Ye Li
Journal:  IEEE Trans Magn       Date:  2017-10-16       Impact factor: 1.700

6.  Optimization and comparison of two practical dual-tuned birdcage configurations for quantitative assessment of articular cartilage with sodium magnetic resonance imaging.

Authors:  Gunthard Lykowsky; Flavio Carinci; Markus Düring; Daniel Weber; Peter M Jakob; Daniel Haddad
Journal:  Quant Imaging Med Surg       Date:  2015-12

7.  Design and test of a double-nuclear RF coil for (1)H MRI and (13)C MRSI at 7T.

Authors:  Omar Rutledge; Tiffany Kwak; Peng Cao; Xiaoliang Zhang
Journal:  J Magn Reson       Date:  2016-04-07       Impact factor: 2.229

8.  Multi-reception strategy with improved SNR for multichannel MR imaging.

Authors:  Bing Wu; Ye Li; Chunsheng Wang; Daniel B Vigneron; Xiaoliang Zhang
Journal:  PLoS One       Date:  2012-08-03       Impact factor: 3.240

Review 9.  Acquisition strategies for spatially resolved magnetic resonance detection of hyperpolarized nuclei.

Authors:  Geoffrey J Topping; Christian Hundshammer; Luca Nagel; Martin Grashei; Maximilian Aigner; Jason G Skinner; Rolf F Schulte; Franz Schilling
Journal:  MAGMA       Date:  2019-12-06       Impact factor: 2.310

10.  Planar quadrature RF transceiver design using common-mode differential-mode (CMDM) transmission line method for 7T MR imaging.

Authors:  Ye Li; Baiying Yu; Yong Pang; Daniel B Vigneron; Xiaoliang Zhang
Journal:  PLoS One       Date:  2013-11-12       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.