Literature DB >> 22129644

Radiofrequency coils for musculoskeletal magnetic resonance imaging.

Kambiz A Asher1, Neal K Bangerter, Ronald D Watkins, Garry E Gold.   

Abstract

Dedicated and specialized radiofrequency coils are critical for high quality musculoskeletal magnetic resonance imaging (MRI). Dedicated coils improve the signal to noise ratio, allowing for faster or higher resolution examinations. Transmit-receive coils can reduce heating at high field strength. Finally, novel radiofrequency coils can be used for assessment of tissue biochemistry, as seen with sodium MRI.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 22129644      PMCID: PMC4400851          DOI: 10.1097/RMR.0b013e31823cd184

Source DB:  PubMed          Journal:  Top Magn Reson Imaging        ISSN: 0899-3459


  20 in total

Review 1.  SMASH imaging.

Authors:  D K Sodickson; M A Griswold; P M Jakob
Journal:  Magn Reson Imaging Clin N Am       Date:  1999-05       Impact factor: 2.266

2.  Transmit SENSE.

Authors:  Ulrich Katscher; Peter Börnert; Christoph Leussler; Johan S van den Brink
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

Review 3.  Parallel imaging at high field strength: synergies and joint potential.

Authors:  Klaas P Pruessmann
Journal:  Top Magn Reson Imaging       Date:  2004-08

4.  The NMR phased array.

Authors:  P B Roemer; W A Edelstein; C E Hayes; S P Souza; O M Mueller
Journal:  Magn Reson Med       Date:  1990-11       Impact factor: 4.668

5.  Custom-fitted 16-channel bilateral breast coil for bidirectional parallel imaging.

Authors:  Anderson N Nnewihe; Thomas Grafendorfer; Bruce L Daniel; Paul Calderon; Marcus T Alley; Fraser Robb; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2011-02-01       Impact factor: 4.668

6.  Sodium MRI of human articular cartilage in vivo.

Authors:  R Reddy; E K Insko; E A Noyszewski; R Dandora; J B Kneeland; J S Leigh
Journal:  Magn Reson Med       Date:  1998-05       Impact factor: 4.668

7.  Fast three dimensional sodium imaging.

Authors:  F E Boada; J S Gillen; G X Shen; S Y Chang; K R Thulborn
Journal:  Magn Reson Med       Date:  1997-05       Impact factor: 4.668

8.  A PIN diode controlled dual-tuned MRI RF coil and phased array for multi nuclear imaging.

Authors:  Seunghoon Ha; Mark J Hamamura; Orhan Nalcioglu; L Tugan Muftuler
Journal:  Phys Med Biol       Date:  2010-04-14       Impact factor: 3.609

9.  Dual-frequency, dual-quadrature, birdcage RF coil design with identical B1 pattern for sodium and proton imaging of the human brain at 1.5 T.

Authors:  G X Shen; F E Boada; K R Thulborn
Journal:  Magn Reson Med       Date:  1997-11       Impact factor: 4.668

10.  Two configurations of the four-ring birdcage coil for 1H imaging and 1H-decoupled 31P spectroscopy of the human head.

Authors:  J Murphy-Boesch; R Srinivasan; L Carvajal; T R Brown
Journal:  J Magn Reson B       Date:  1994-02
View more
  6 in total

Review 1.  Quantitative sodium magnetic resonance imaging of cartilage, muscle, and tendon.

Authors:  Neal K Bangerter; Grayson J Tarbox; Meredith D Taylor; Joshua D Kaggie
Journal:  Quant Imaging Med Surg       Date:  2016-12

2.  Integrated use of cardiac MRI and the CardioMEMS™ HF system in PAH: the utility of coincident pressure and volume in RV failure-the NHLBI-VITA trial.

Authors:  Robert W W Biederman; Mark Doyle; Priscilla Correa-Jaque; Geetha Rayarao; Raymond L Benza
Journal:  Cardiovasc Diagn Ther       Date:  2019-10

3.  Effect of radiofrequency shield diameter on signal-to-noise ratio at ultra-high field MRI.

Authors:  Bei Zhang; Gregor Adriany; Lance Delabarre; Jerahmie Radder; Russell Lagore; Brian Rutt; Qing X Yang; Kamil Ugurbil; Riccardo Lattanzi
Journal:  Magn Reson Med       Date:  2021-01-19       Impact factor: 3.737

4.  Maximizing sensitivity for fast GABA edited spectroscopy in the visual cortex at 7 T.

Authors:  Arjan D Hendriks; Alessio Fracasso; Catalina S Arteaga de Castro; Mark W J M Gosselink; Peter R Luijten; Natalia Petridou; Dennis W J Klomp
Journal:  NMR Biomed       Date:  2018-02-14       Impact factor: 4.044

Review 5.  Reporting knee meniscal tears: technical aspects, typical pitfalls and how to avoid them.

Authors:  Nicolae V Bolog; Gustav Andreisek
Journal:  Insights Imaging       Date:  2016-02-16

Review 6.  Rapid Knee MRI Acquisition and Analysis Techniques for Imaging Osteoarthritis.

Authors:  Akshay S Chaudhari; Feliks Kogan; Valentina Pedoia; Sharmila Majumdar; Garry E Gold; Brian A Hargreaves
Journal:  J Magn Reson Imaging       Date:  2019-11-21       Impact factor: 4.813

  6 in total