Literature DB >> 10873194

Dual resonant birdcage coils for 1H detected 13C microscopic imaging at 11.7 T.

A M Hudson1, W Köckenberger, R W Bowtell.   

Abstract

Liquid state, rotating frame cross polarisation experiments are very sensitive to RF field inhomogeneity. In this work, we present an easily fabricated, co-resident high- and low-pass linear birdcage resonator, optimised to perform liquid state rotating frame polarisation transfer at 1H and 13C frequencies. Both the RF fields have been experimentally mapped, and used to validate the spatial signal dependence of a proton detected, 13C image. The predicted performance was then confirmed using PRAWN-based, cyclic J-cross polarisation (CYCLCROP) imaging. A novel variant of a B(1)-field mapping approach is also presented, using the signal enhancement of the CYCLCROP sequence to generate proton detected, 13C field maps.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10873194     DOI: 10.1016/s1352-8661(00)00068-5

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  7 in total

1.  PRAWN: mixing sequences for selective heteronuclear J cross polarization.

Authors:  N Chandrakumar; R Kimmich
Journal:  J Magn Reson       Date:  1999-03       Impact factor: 2.229

2.  A technique for double resonant operation of birdcage imaging coils.

Authors:  P M Joseph; D Lu
Journal:  IEEE Trans Med Imaging       Date:  1989       Impact factor: 10.048

3.  Multiple tuning of birdcage resonators.

Authors:  S Amari; A M Uluğ; J Bornemann; P C van Zijl; P B Barker
Journal:  Magn Reson Med       Date:  1997-02       Impact factor: 4.668

4.  Double resonant quadrature birdcage.

Authors:  J R Fitzsimmons; B L Beck; H R Brooker
Journal:  Magn Reson Med       Date:  1993-07       Impact factor: 4.668

5.  Double-tuned four-ring birdcage resonators for in vivo 31P-nuclear magnetic resonance spectroscopy at 11.75 T.

Authors:  T Lanz; M von Kienlin; W Behr; A Haase
Journal:  MAGMA       Date:  1997-09       Impact factor: 2.310

6.  Dual-frequency, dual-quadrature, birdcage RF coil design with identical B1 pattern for sodium and proton imaging of the human brain at 1.5 T.

Authors:  G X Shen; F E Boada; K R Thulborn
Journal:  Magn Reson Med       Date:  1997-11       Impact factor: 4.668

7.  Two configurations of the four-ring birdcage coil for 1H imaging and 1H-decoupled 31P spectroscopy of the human head.

Authors:  J Murphy-Boesch; R Srinivasan; L Carvajal; T R Brown
Journal:  J Magn Reson B       Date:  1994-02
  7 in total
  2 in total

1.  Evaluation of a New 1H/31P Dual-Tuned Birdcage Coil for 31P Spectroscopy.

Authors:  Wm Potter; L Wang; Kk McCully; Q Zhao
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2013-08-01       Impact factor: 1.176

2.  Design and test of a double-nuclear RF coil for (1)H MRI and (13)C MRSI at 7T.

Authors:  Omar Rutledge; Tiffany Kwak; Peng Cao; Xiaoliang Zhang
Journal:  J Magn Reson       Date:  2016-04-07       Impact factor: 2.229

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.