The MS-2 (Abbott Laboratories) system for automated antimicrobial susceptibility testing was evaluated for both accuracy and general utility in our clinical laboratory. A total of 984 fresh clinical bacterial isolates (745 gram-negative, 239 gram-positive) were tested with the MS-2 system, and results were compared directly with those from a conventional agar disk diffusion method. Discrepancies between the two methods were categorized as very major, major, and minor. For gram-positive isolates, full accord (all discrepancies considered) was 91.6%, and essential accord (minor discrepancies not included) was 96.2%. With gram-negative isolates, full accord was found to be 93.9%, with essential accord of 97.9%. Aggrement as a function both of organism group and of antimicrobial agent was determined. Full accord of 90% or more was found for all major organism groups tested, with the exception of enterococci, where discrepant results between the two methods were observed. Mean test time for all isolates tested was 4.3 h. The MS-2 was found to be an accurate and highly automated instrument which required minimal technician time and was readily adaptable to work flow in our clinical laboratory.

Entities:  

Mesh:

Substances:

Year:  1980        PMID: 7419705      PMCID: PMC273629          DOI: 10.1128/jcm.12.4.527-532.1980

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  3 in total

1.  Laboratory evaluation of a rapid, automatic susceptibility testing system: report of a collaborative study.

Authors:  C Thornsberry; T L Gavan; J C Sherris; A Balows; J M Matsen; L D Sabath; F Schoenknecht; L D Thrupp; J A Washington
Journal:  Antimicrob Agents Chemother       Date:  1975-04       Impact factor: 5.191

2.  Antibiotic susceptibility testing by a standardized single disk method.

Authors:  A W Bauer; W M Kirby; J C Sherris; M Turck
Journal:  Am J Clin Pathol       Date:  1966-04       Impact factor: 2.493

3.  Clinical laboratory evaluation of the Abbott MS-2 automated antimicrobial susceptibility testing system: report of a collaborative study.

Authors:  C Thornsberry; J P Anhalt; J A Washington; L R McCarthy; F D Schoenknecht; J C Sherris; H J Spencer
Journal:  J Clin Microbiol       Date:  1980-09       Impact factor: 5.948

  3 in total
  10 in total

1.  Evaluation of the AutoMicrobic system Gram-Negative General Susceptibility-Plus Card.

Authors:  K G Van Horn; A M Vandernoot; E W Burke; J C McKitrick
Journal:  J Clin Microbiol       Date:  1984-10       Impact factor: 5.948

2.  Concurrent comparability of automated systems and commercially prepared microdilution trays for susceptibility testing.

Authors:  S L Hansen; P K Freedy
Journal:  J Clin Microbiol       Date:  1983-05       Impact factor: 5.948

3.  Comparison of three automated systems for antimicrobial susceptibility testing of gram-negative bacilli.

Authors:  M T Kelly; J M Latimer; L C Balfour
Journal:  J Clin Microbiol       Date:  1982-05       Impact factor: 5.948

4.  Direct identification and susceptibility testing of gram-negative bacilli from BACTEC bottles by use of the MS-2 system with updated bacterial identification software.

Authors:  J R Dipersio; S M Ficorilli; F J Varga
Journal:  J Clin Microbiol       Date:  1984-12       Impact factor: 5.948

5.  Laboratory evaluation of the Anderson Technical semiautomated susceptibility testing system.

Authors:  G A McKinley; D J Fagerberg; B A George
Journal:  Antimicrob Agents Chemother       Date:  1981-12       Impact factor: 5.191

6.  Evaluation of four newer antimicrobial agents in the Avantage susceptibility test system.

Authors:  D N Wright; J M Matsen; J R DiPersio; M Kirk; B Saxon; S M Ficorilli; H J Spencer
Journal:  J Clin Microbiol       Date:  1989-10       Impact factor: 5.948

7.  Reliability of the MS-2 system in detecting methicillin-resistant Staphylococcus aureus.

Authors:  J M Boyce; R L White; M C Bonner; W R Lockwood
Journal:  J Clin Microbiol       Date:  1982-02       Impact factor: 5.948

8.  Methicillin-resistant Staphylococcus aureus susceptibility testing with Abbott MS-2 system.

Authors:  J R Carlson; F E Conley; D L Cahall
Journal:  Antimicrob Agents Chemother       Date:  1982-04       Impact factor: 5.191

9.  Comparison of two automated instrument systems for rapid susceptibility testing of gram-negative bacilli.

Authors:  J E Johnson; J H Jorgensen; S A Crawford; J S Redding; R C Pruneda
Journal:  J Clin Microbiol       Date:  1983-12       Impact factor: 5.948

10.  Detection of methicillin-resistant Staphylococcus aureus by microdilution and disk elution susceptibility systems.

Authors:  J M Boyce; L S Lytle; D A Walsh
Journal:  J Clin Microbiol       Date:  1984-12       Impact factor: 5.948

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.