Literature DB >> 6919413

Methicillin-resistant Staphylococcus aureus susceptibility testing with Abbott MS-2 system.

J R Carlson, F E Conley, D L Cahall.   

Abstract

The antimicrobial susceptibilities of 100 methicillin=resistant Staphylococcus aureus strains were concurrently determined by the Abbott MS-2 System and by the standard disk diffusion method. Agreement between the two methods was 94% or greater for all of the antibiotics tested except for methicillin and gentamicin. This study indicates that the Abbott MS-2 cannot be relied upon for detection of methicillin resistance in clinical S. aureus isolates.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 6919413      PMCID: PMC181967          DOI: 10.1128/AAC.21.4.676

Source DB:  PubMed          Journal:  Antimicrob Agents Chemother        ISSN: 0066-4804            Impact factor:   5.191


  3 in total

1.  Clinical laboratory evaluation of the Abbott MS-2 automated antimicrobial susceptibility testing system: report of a collaborative study.

Authors:  C Thornsberry; J P Anhalt; J A Washington; L R McCarthy; F D Schoenknecht; J C Sherris; H J Spencer
Journal:  J Clin Microbiol       Date:  1980-09       Impact factor: 5.948

2.  Clinical evaluation of automated antibiotic susceptibility testing with the MS-2 system.

Authors:  W G Barnes; L R Green; R L Talley
Journal:  J Clin Microbiol       Date:  1980-10       Impact factor: 5.948

3.  Reliability of the microdilution technic for detection of methicillin-resistant strains of staphylococcus aureus.

Authors:  A L Barry; R E Badal
Journal:  Am J Clin Pathol       Date:  1977-05       Impact factor: 2.493

  3 in total
  13 in total

Review 1.  Methicillin-resistant staphylococci: detection methods and treatment of infections.

Authors:  C J Hackbarth; H F Chambers
Journal:  Antimicrob Agents Chemother       Date:  1989-07       Impact factor: 5.191

Review 2.  Methicillin-resistant staphylococci.

Authors:  H F Chambers
Journal:  Clin Microbiol Rev       Date:  1988-04       Impact factor: 26.132

3.  Variation in the abilities of automated, commercial, and reference methods to detect methicillin-resistant (heteroresistant) Staphylococcus aureus.

Authors:  S L Hansen; P K Freedy
Journal:  J Clin Microbiol       Date:  1984-09       Impact factor: 5.948

4.  Evaluation of the Cathra inoculating device for susceptibility testing of methicillin-susceptible and methicillin-resistant Staphylococcus aureus strains.

Authors:  J M Boyce; M C Bonner; W R Lockwood
Journal:  Antimicrob Agents Chemother       Date:  1982-11       Impact factor: 5.191

5.  Detection of oxacillin-resistant staphylococci by the AutoMicrobic system.

Authors:  R W Stotler; M C Meyer
Journal:  J Clin Microbiol       Date:  1983-11       Impact factor: 5.948

6.  Rapid recognition of methicillin-resistant Staphylococcus aureus by use of automated test systems.

Authors:  J H Jorgensen; J Redding; J E Johnson; V Holloway; R J Almeida
Journal:  J Clin Microbiol       Date:  1984-09       Impact factor: 5.948

7.  Successful use of broth microdilution in susceptibility tests for methicillin-resistant (heteroresistant) staphylococci.

Authors:  C Thornsberry; L K McDougal
Journal:  J Clin Microbiol       Date:  1983-11       Impact factor: 5.948

8.  Autobac susceptibility testing of methicillin-resistant Staphylococcus aureus isolated in an Australian hospital.

Authors:  R A Putland; M D Guinness
Journal:  J Clin Microbiol       Date:  1985-11       Impact factor: 5.948

9.  Detection of methicillin-resistant Staphylococcus aureus by microdilution and disk elution susceptibility systems.

Authors:  J M Boyce; L S Lytle; D A Walsh
Journal:  J Clin Microbiol       Date:  1984-12       Impact factor: 5.948

10.  Reevaluation of the ability of the standardized disk diffusion test to detect methicillin-resistant strains of Staphylococcus aureus.

Authors:  J M Boyce
Journal:  J Clin Microbiol       Date:  1984-06       Impact factor: 5.948

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.