Literature DB >> 7096560

Comparison of three automated systems for antimicrobial susceptibility testing of gram-negative bacilli.

M T Kelly, J M Latimer, L C Balfour.   

Abstract

Several instruments for automated or semiautomated susceptibility testing are currently available. Three of these instruments, Autobac (General Diagnostics, Warner-Lambert Co., Morris Plains, N.J.), MS-2 (Abbott Laboratories, Dallas, Tex.), and AutoMicrobic system (AMS) (Vitek, Inc., Hazelwood, Mo.) were compared for antimicrobial susceptibility testing of gram-negative bacilli. A total of 207 isolates representing 29 species of gram-negative bacilli were tested simultaneously by each instrument and by a standardized disk diffusion reference method. Nine antimicrobial agents, including ampicillin, carbenicillin, cephalothin, gentamicin, tobramycin, amikacin, tetracycline, trimethoprim-sulfamethoxazole, and nitrofurantoin were tested. Discrepancies between the results of the automated and reference disk diffusion methods were resolved by agar dilution testing. Overall, 93% of the Autobac and MS-2 results and 83% of the AMS results were in agreement with the results obtained by the reference methods. The results of the Autobac, MS-2, and AMS systems respectively included 3.3, 2.3, and 4.2% major and very major discrepancies. Excessive testing discrepancies were found for certain drugs, including ampicillin, tetracycline, and nitrofurantoin, and for certain organisms, including species of Providencia, Serratia, and Citrobacter. The results of this comparison of three automated systems for antimicrobial susceptibility testing indicate that the Autobac and MS-2 instruments provided highly reliable results. The AMS need further development of its susceptibility testing capability to eliminate an unacceptably high number of minor discrepancies.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 7096560      PMCID: PMC272211          DOI: 10.1128/jcm.15.5.902-905.1982

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  4 in total

1.  Laboratory evaluation of a rapid, automatic susceptibility testing system: report of a collaborative study.

Authors:  C Thornsberry; T L Gavan; J C Sherris; A Balows; J M Matsen; L D Sabath; F Schoenknecht; L D Thrupp; J A Washington
Journal:  Antimicrob Agents Chemother       Date:  1975-04       Impact factor: 5.191

2.  Clinical laboratory evaluation of the Abbott MS-2 automated antimicrobial susceptibility testing system: report of a collaborative study.

Authors:  C Thornsberry; J P Anhalt; J A Washington; L R McCarthy; F D Schoenknecht; J C Sherris; H J Spencer
Journal:  J Clin Microbiol       Date:  1980-09       Impact factor: 5.948

3.  Clinical evaluation of automated antibiotic susceptibility testing with the MS-2 system.

Authors:  W G Barnes; L R Green; R L Talley
Journal:  J Clin Microbiol       Date:  1980-10       Impact factor: 5.948

4.  Comparison of drug sensitivity testing with microdilution quantitative minimum inhibitory concentration and the Autobac I system.

Authors:  C V Jacob; J Kleineman
Journal:  J Clin Microbiol       Date:  1980-05       Impact factor: 5.948

  4 in total
  17 in total

1.  Evaluation of the Cobas-Bact system for direct and rapid identification and antimicrobial susceptibility testing of gram-negative rods from positive blood culture broths.

Authors:  W Kamm; A Wenger; J Bille
Journal:  J Clin Microbiol       Date:  1989-01       Impact factor: 5.948

2.  Evaluation of the Autoscan Walkaway system for rapid identification and susceptibility testing of gram-negative bacilli.

Authors:  M T Kelly; C Leicester
Journal:  J Clin Microbiol       Date:  1992-06       Impact factor: 5.948

3.  Comparison of a highly automated 5-h susceptibility testing system, the Cobas-Bact, with two reference methods: Kirby-Bauer disk diffusion and broth microdilution.

Authors:  P R Murray; A C Niles; R L Heeren
Journal:  J Clin Microbiol       Date:  1987-12       Impact factor: 5.948

4.  Accuracy and reproducibility of the AutoMicrobic System Gram-Negative General Susceptibility-Plus Card for testing selected challenge organisms.

Authors:  H L Nadler; C Dolan; L Mele; S R Kurtz
Journal:  J Clin Microbiol       Date:  1985-09       Impact factor: 5.948

5.  Comparison of the Cobas-Bact five-hour susceptibility testing system with the NCCLS agar diffusion and dilution methods.

Authors:  J Wüst; W Heizmann; U Hardegger; B Manncke
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1988-08       Impact factor: 3.267

6.  Automated interpretation of disk diffusion antibiotic susceptibility tests with the radial profile analysis algorithm.

Authors:  G Hejblum; V Jarlier; J Grosset; A Aurengo
Journal:  J Clin Microbiol       Date:  1993-09       Impact factor: 5.948

7.  Rapid antimicrobial susceptibility testing of Gram-negative clinical isolates with the AutoMicrobic system.

Authors:  B A Backes; S J Cavalieri; J T Rudrik; E M Britt
Journal:  J Clin Microbiol       Date:  1984-06       Impact factor: 5.948

8.  Evaluation of the AutoMicrobic system Gram-Negative General Susceptibility-Plus Card.

Authors:  K G Van Horn; A M Vandernoot; E W Burke; J C McKitrick
Journal:  J Clin Microbiol       Date:  1984-10       Impact factor: 5.948

9.  Evaluation of the AutoMicrobic system for identification and susceptibility testing of gram-negative bacilli.

Authors:  B F Woolfrey; R T Lally; M N Ederer; C O Quall
Journal:  J Clin Microbiol       Date:  1984-12       Impact factor: 5.948

10.  Comparison of two automated instrument systems for rapid susceptibility testing of gram-negative bacilli.

Authors:  J E Johnson; J H Jorgensen; S A Crawford; J S Redding; R C Pruneda
Journal:  J Clin Microbiol       Date:  1983-12       Impact factor: 5.948

View more