Literature DB >> 6490849

Evaluation of the AutoMicrobic system Gram-Negative General Susceptibility-Plus Card.

K G Van Horn, A M Vandernoot, E W Burke, J C McKitrick.   

Abstract

The MICs of 10 antimicrobial agents were determined for 1,000 clinical aerobic and facultatively anaerobic gram-negative bacilli by the 6-h AutoMicrobic system Gram-Negative General Susceptibility-Plus Card (GSC+) (Vitek Systems, Inc., Hazelwood, Mo.) and by an 18-h reference agar dilution method. Results obtained by both systems were evaluated for twofold dilution discrepancies and for interpretive category discrepancies. MICs that differed by more than one twofold dilution between the two test systems were considered to be discrepant. The overall twofold dilution agreement of the GSC+ MICs to agar dilution MICs was 94.0%. The agreement for each drug tested ranged from 91.7% (ampicillin and chloramphenicol) to 96.5% (carbenicillin). Interpretive categories were considered in agreement when the susceptibility interpretations obtained by the two systems were both very susceptible, moderately susceptible, or resistant. The overall interpretive category agreement was 80.5%. This agreement increased to 95.8% when all minor errors (moderately susceptible, one system; very susceptible, the other system) that would not affect therapy were omitted. The AutoMicrobic system GSC+ provides rapid and accurate susceptibility test results for clinical aerobic and facultatively anaerobic gram-negative bacilli.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6490849      PMCID: PMC271399          DOI: 10.1128/jcm.20.4.630-635.1984

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  9 in total

1.  Laboratory evaluation of a rapid, automatic susceptibility testing system: report of a collaborative study.

Authors:  C Thornsberry; T L Gavan; J C Sherris; A Balows; J M Matsen; L D Sabath; F Schoenknecht; L D Thrupp; J A Washington
Journal:  Antimicrob Agents Chemother       Date:  1975-04       Impact factor: 5.191

2.  Evaluation of the Sceptor microdilution antibiotic susceptibility testing system: a collaborative investigation.

Authors:  R N Jones; C Thornsberry; A L Barry; T L Gavan
Journal:  J Clin Microbiol       Date:  1981-01       Impact factor: 5.948

3.  Concurrent comparability of automated systems and commercially prepared microdilution trays for susceptibility testing.

Authors:  S L Hansen; P K Freedy
Journal:  J Clin Microbiol       Date:  1983-05       Impact factor: 5.948

4.  Identification of Enterobacteriaceae by the automicrobic system: Enterobacteriaceae biochemical cards versus Enterobacteriaceae-plus biochemical cards.

Authors:  A L Barry; R E Badal
Journal:  J Clin Microbiol       Date:  1982-04       Impact factor: 5.948

5.  Comparison of three automated systems for antimicrobial susceptibility testing of gram-negative bacilli.

Authors:  M T Kelly; J M Latimer; L C Balfour
Journal:  J Clin Microbiol       Date:  1982-05       Impact factor: 5.948

6.  Clinical evaluation of new AMS GSC plus card.

Authors:  M Dudley; W F Nauschuetz; S V Juchau
Journal:  Diagn Microbiol Infect Dis       Date:  1983-06       Impact factor: 2.803

7.  Clinical evaluation of automated antibiotic susceptibility testing with the MS-2 system.

Authors:  W G Barnes; L R Green; R L Talley
Journal:  J Clin Microbiol       Date:  1980-10       Impact factor: 5.948

8.  Comparison of two automated instrument systems for rapid susceptibility testing of gram-negative bacilli.

Authors:  J E Johnson; J H Jorgensen; S A Crawford; J S Redding; R C Pruneda
Journal:  J Clin Microbiol       Date:  1983-12       Impact factor: 5.948

9.  Automated microbiological detection/identification system.

Authors:  C Aldridge; P W Jones; S Gibson; J Lanham; M Meyer; R Vannest; R Charles
Journal:  J Clin Microbiol       Date:  1977-10       Impact factor: 5.948

  9 in total
  5 in total

1.  Accuracy and reproducibility of the AutoMicrobic System Gram-Negative General Susceptibility-Plus Card for testing selected challenge organisms.

Authors:  H L Nadler; C Dolan; L Mele; S R Kurtz
Journal:  J Clin Microbiol       Date:  1985-09       Impact factor: 5.948

2.  Rapid MIC testing with the sensititre autoreader.

Authors:  J L Staneck; S D Allen; E E Harris; R C Tilton
Journal:  J Clin Microbiol       Date:  1988-01       Impact factor: 5.948

3.  Comparative evaluation of four systems for determining susceptibility of gram-positive organisms.

Authors:  D Henry; L Kunzer; J Ngui-Yen; J Smith
Journal:  J Clin Microbiol       Date:  1986-04       Impact factor: 5.948

4.  Evaluation of the AutoMicrobic system for susceptibility testing of aminoglycosides and gram-negative bacilli.

Authors:  J A Hindler; D A Bruckner
Journal:  J Clin Microbiol       Date:  1987-03       Impact factor: 5.948

5.  Evaluation of the Cobas Bact automated system for susceptibility testing of Enterobacteriaceae, Pseudomonas aeruginosa, and Enterococcus faecalis to azlocillin, mezlocillin, and ciprofloxacin compared to NCCLS and DIN standards.

Authors:  W Heizmann; H Werner; F Heilmann
Journal:  Infection       Date:  1988       Impact factor: 3.553

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.