Hélène Casalta1, Valeria Busoni2, Justine Eppe1, Sigrid Grulke3, Anne-Christine Merveille2, Nassim Moula4,5, Kris Gommeren2.
Abstract
Ultrasonographic measurements of the caudal vena cava (CVC) and aorta (Ao) are known as reliable tools to assess intravascular volume status in humans. The aim of this study was to evaluate the feasibility of obtaining ultrasonographical measurements of CVC and Ao in two different views, assess intra- and interobserver variability, and study the effect of sex, age, body weight, and breed on measurements in healthy calves. The diameter and area of CVC and Ao were measured by a single investigator in two anatomic sites (subxiphoid and paralumbar window) in 48 calves aged less than 60 days and then repeated 2.5 months after the first assessment. For intra- and interobserver variability assessment, CVC and Ao measurements were repeated by three observers on five randomly selected calves. CVC and Ao measurements were easily obtained in PV and more difficult to obtain in SV. CVC and Ao area in PV showed high repeatability and reproducibility. A positive correlation was highlighted between age and CVC and Ao measurements in both sites. In conclusion, CVC size assessment by point of care ultrasound can be easily performed at a paralumbar site in calves under 4 months of age and could be used to assess intravascular volume status.Entities:
Keywords: calf; caudal vena cava; intravascular volume status; point-of-care ultrasound
Year: 2022 PMID: 35878325 PMCID: PMC9322146 DOI: 10.3390/vetsci9070308
Source DB: PubMed Journal: Vet Sci ISSN: 2306-7381
Figure 1Subxiphoid site: (a) probe placement site and (b) ultrasonographic view of caudal vena cava (CVC) crossing the diaphragm (Yellow arrow). The blue star shows the position of the probe marker. CR: cranial; CAUD: caudal.
Figure 2Paralumbar site: (a) probe placement site and (b) transversal and (c) longitudinal ultrasonographic views of caudal vena cava (CVC) and aorta (Ao). The blue star shows the position of the probe marker in transversal and longitudinal view. CR: cranial; CAUD: caudal.
Ultrasonographic measurements and calculated variables (mean and standard deviation (±SD)) obtained on images from the paralumbar view and subxiphoid view for each observer (OBS1, OBS2 and OBS3) in the intra- and interobserver agreement study, with p-values of effects of the observer (OBS), the repetition (REP), and interaction between observer and repetition (OBS/REP) on those values.
| POCUS Views | OBS1 | OBS2 | OBS3 | ||||
|---|---|---|---|---|---|---|---|
| OBS | REP | OBS/REP | |||||
|
| Ao diameter (cm) | 1.17±0.03 | 1.15 ± 0.03 | 1.21 ± 0.03 | 0.45 | 1.00 | 1.00 |
| CVC diameter (cm) | 1.06 ± 0.08 | 1.00 ± 0.12 | 0.94 ± 0.05 | 0.03 | 0.99 | 1.00 | |
| CVC/Ao diameter index | 0.91 ± 0.03 | 0.88 ± 0.03 | 0.77 ± 0.03 | 0.002 | 0.98 | 0.99 | |
|
| Ao area (cm2) | 0.91 ± 0.03 | 0.88 ± 0.03 | 0.77 ± 0.03 | 0.79 | 0.87 | 0.99 |
| CVC area (cm2) | 1.08 ± 0.03 | 1.02 ± 0.03 | 1.02 ± 0.03 | 0.41 | 0.61 | 0.99 | |
| CVC/Ao area index | 0.99 ± 0.04 | 0.86 ± 0.04 | 1.02 ± 0.04 | 0.006 | 0.98 | 1.00 | |
|
| CVCmin (cm) | 0.33 ± 0.02 | 0.39 ± 0.02 | 0.37 ± 0.02 | 0.09 | 0.29 | 0.92 |
| CVCmax (cm) | 0.74 ± 0.04 | 0.89 ± 0.04 | 0.85 ± 0.04 | 0.02 | 0.99 | 0.99 | |
PV-long: longitudinal paralumbar view; PV-trans: transversal paralumbar view; SV: subxiphoid view.
Figure 3Evolution over time of the percentage (%) of the successful SV cineloop acquisition in calves in the first part of the protocol. Each visit is shown as the completion date (day/month/year). Score 1: No cineloop was recorded because of the impossibility to visualize the CVC on the xyphoid site. Score 2: Cineloop was recorded but the margin of CVC was unclear which made obtaining measurements of the CVC impossible. Score 3: Cineloop was recorded with well-defined margins of the CVC that allowed precise measurements.
Figure 4Box and whisker plots of the CVC measurements at the subxiphoid site when the CVC crossed the diaphragm. The CVCmin is CVC minimal diameter and the CVCmax is CVC maximal diameter measured.
Ultrasonographic measurements and calculated variables (mean and standard deviation (±SD) or median and interquartile range (IQR)) obtained from images of the paralumbar view in 48 calves on the first part of the study.
| POCUS Views | Ao Diameter (cm) | CVC Diameter (cm) | CVC/Ao Diameter Index | Ao Area (cm2) | CVC Area (cm2) | CVC/Ao Area Index |
|---|---|---|---|---|---|---|
|
| 1.20 (1.09–1.35) | 0.86 ± 0.23 | 0.71 ± 0.22 | - | - | - |
|
| 1.25 (1.08–1.39) | - | - | 1.26 ± 0.39 | 1.06 ± 0.42 | 0.89 ± 0.34 |
PV-long: longitudinal paralumbar view; PV-trans: transversal paralumbar view.
Figure 5Correlation coefficients (R2) between calves’ age and weight and caudal vena cava (CVC) and aorta (Ao) measurements at paralumbar views (PV). ***: p < 0.001, **: p < 0.01, *: p < 0.05. CVCdLong and AodLong are respectively CVC and Ao diameter at longitudinal PV, and CVCdLong and AodLong are the CVC and Ao diameter index in longitudinal PV. AodTrans is Ao diameter in transversal PV, CVCaTrans and AoaTrans are respectively CVC and Ao area at transversal PV, and CVCaTrans and AoaTrans are the CVC and Ao area index in transversal PV.
Ultrasonographic measurements and calculated variables (mean ± SD) obtained on images from the paralumbar view in 17 calves for the first part of the study (T1) and the second part of the study (T2).
| POCUS View | T1 | T2 | ||
|---|---|---|---|---|
|
| Ao diameter (cm) | 1.09 ± 0.10 | 1.24 ± 0.14 | 0.0004 |
| CVC diameter (cm) | 0.92 ± 0.14 | 1.25 ± 0.24 | 0.00005 | |
| CVC/Ao diameter index | 0.84 ± 0.09 | 0.97 ± 0.19 | 0.009 | |
|
| Ao diameter (cm) | 1.13 ± 0.12 | 1.28 ± 0.13 | 0.00001 |
| Ao area (cm2) | 0.99 ± 0.23 | 1.05 ± 0.3 | 0.3269 | |
| CVC area (cm2) | 1.04 ± 0.35 | 1.55 ± 0.6 | 0.002 | |
| CVC/Ao area index | 1.05 ± 0.26 | 0.97 ± 0.19 | 0.002 |
PV-long = longitudinal paralumbar view, PV-trans = transversal paralumbar view, Ao = aorta, CVC = caudal vena cava. p-value < 0.01 indicates significant difference between measurements in T1 and T2.