Literature DB >> 29024163

Ultrasonographic measurement of caudal vena cava to aorta ratios for determination of volume depletion in normal beagle dogs.

Jungmin Kwak1, Hakyoung Yoon1, Jaehwan Kim1, Minjoo Kim1, Kidong Eom1,2.   

Abstract

A noninvasive method for quantifying hydration status would be helpful for clinical management and for research applications in dogs. This prospective, experimental, pilot study aimed to assess the feasibility of ultrasonographic measurement of the caudal vena cava to aorta ratio as a method for quantifying volume depletion in dogs. In 12 normal beagle dogs, furosemide was administered intravenously at a dose of 1 mg/kg, every 2 h, for 8 h, to induce consecutive volume depletion. Every 30 min after administration, ultrasonographic images of the caudal vena cava and aorta, and physical and biological parameters related to dehydration were acquired. On transverse and longitudinal planes of caudal vena cava and aorta images, the height and area of the caudal vena cava and aorta were measured to calculate the caudal vena cava/aorta ratios. All images were acquired by approaching from the right intercostal space with the dogs in left lateral recumbency. A negative correlation was present between the percentage of weight loss in dogs and all four investigated caudal vena cava/aorta ratios (transverse plane width of the caudal vena cava [TW]/aorta; transverse plane height of caudal vena cava [TH]/aorta; longitudinal plane area of the caudal vena cava [TA]/aorta; and longitudinal plane maximal height of the caudal vena cava [L]/aorta). Significant differences (P < 0.001) were seen between dogs with and without clinical signs of dehydration for all caudal vena cava/aorta ratios. Findings indicated that ultrasonographic caudal vena cava/aorta ratios are feasible methods for quantifying volume depletion and for use as an adjunct to standard subjective methods for estimating hydration status in dogs.
© 2017 American College of Veterinary Radiology.

Entities:  

Keywords:  canine; caudal vena cava; dehydration; ultrasonic diagnosis; ultrasound

Mesh:

Year:  2017        PMID: 29024163     DOI: 10.1111/vru.12566

Source DB:  PubMed          Journal:  Vet Radiol Ultrasound        ISSN: 1058-8183            Impact factor:   1.363


  3 in total

1.  Ultrasonographical Assessment of Caudal Vena Cava Size through Different Views in Healthy Calves: A Pilot Study.

Authors:  Hélène Casalta; Valeria Busoni; Justine Eppe; Sigrid Grulke; Anne-Christine Merveille; Nassim Moula; Kris Gommeren
Journal:  Vet Sci       Date:  2022-06-22

2.  Establishment of reference values of the caudal vena cava by fast-ultrasonography through different views in healthy dogs.

Authors:  Elodie Darnis; Soren Boysen; Anne-Christine Merveille; Loïc Desquilbet; Serge Chalhoub; Kris Gommeren
Journal:  J Vet Intern Med       Date:  2018-05-10       Impact factor: 3.333

3.  Transabdominal ultrasonographic measurement of caudal vena cava to aorta derived ratios in clinically healthy neonatal foals.

Authors:  Chiara Del Prete; Francesca Freccero; Aliai Lanci; Gayle D Hallowell; Chiara Bullone; Carolina Castagnetti; Maria Pia Pasolini
Journal:  Vet Med Sci       Date:  2021-05-03
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.